Comparison of Laser Diffraction Measurements by Mastersizer X and Spraytec to Characterize Droplet Size Distribution of Medical Liquid Aerosols

2014 ◽  
Vol 27 (2) ◽  
pp. 94-102 ◽  
Author(s):  
Nicolas Lelong ◽  
Alexandra Junqua-Moullet ◽  
Patrice Diot ◽  
Laurent Vecellio
2018 ◽  
Vol 34 (3) ◽  
pp. 507-513 ◽  
Author(s):  
Bruno C Vieira ◽  
Guilherme S Alves ◽  
Fernando K Carvalho ◽  
João Paulo AR Da Cunha ◽  
Ulisses R Antuniassi ◽  
...  

Abstract. Drift is one of the most hazardous consequences of an improper aerial application of glyphosate. Wind, droplet size, application height, and distance to sensitive areas are the most important factors for drift. Droplet size is affected by nozzle, operating pressure, flight speed, deflection angle, and physicochemical properties of the spray solution. The objective of this study was to evaluate the effect of flight speed and the use of adjuvants on droplet size spectra in aerial applications of glyphosate. The study was conducted in a high-speed wind tunnel at the Pesticide Application Technology Laboratory (University of Nebraska-Lincoln, West Central Research and Extension Center, North Platte, Neb.). Aerial applications were simulated with four different airspeeds (44.4, 52.8, 61.1, and 69.4 m/s) and glyphosate combined with adjuvants (high surfactant oil concentrate, microemulsion drift reduction agent, nonionic and acidifier surfactant, polyvinyl polymer, and glyphosate alone). Droplet size spectra were evaluated using a Sympatec Helos laser diffraction instrument measuring 90 cm from the nozzle tip (CP11-4015). The volumetric droplet size distribution parameters (VMD, DV0.1, and DV0.9) and the percentage of droplets smaller than 100 µm were reported. The relative span was calculated to indicate the droplet size homogeneity [(DV0.9 - DV0.1) / DV0.5]. Glyphosate solutions with adjuvants had a larger VMD than the glyphosate alone solution at 44.4 m/s wind speed. At 69.4 m/s only the glyphosate solution with polymer had a larger VMD. Conversely, the glyphosate with polymer had the smallest DV0.1, and the greatest relative span and percentage of droplets smaller than 100 µm. Generally, adjuvants influence on droplet size was diminished or muted as the airspeed was increased. The polymer tested in this study failed as a drift agent reduction agent, especially at higher airspeeds. While not all polymers were tested, cautions should be taken if using these types of adjuvants in aerial applications. The interaction of airspeed and adjuvants influencing droplet size distribution in aerial applications of glyphosate should be considered by applicators in order to mitigate glyphosate drift to the surrounding environment. Further studies are necessary to better understand the interaction between solution viscosity and air shear effect on the atomization process and droplet size distribution, as well as confirm that trends hold true for other adjuvants in the polymer class. Although applicators tend to operate aircrafts with increased flight speeds in order to optimize the application time efficiency, this practice can reduce or mute adjuvants effects, decrease the droplet size distribution, and increase drift potential in aerial applications of glyphosate. Keywords: Drift reduction technologies, Flight speed, High-speed wind tunnel, Laser diffraction.


Author(s):  
P. J. Brizio ◽  
M. D. Protheroe ◽  
A. M. Al-Jumaily

Three methods of determining the droplet size distribution in aerosols are investigated. These are based on using photography, impact/capture and optics, respectively, to determine the droplet size distribution in an air-water aerosol produced from an ultrasonic atomization device. Comparison is made between these methods based on the required procedure, equipment used and results obtained. An optical method, based on laser diffraction, stands out in terms of accuracy and ease of use although it requires relatively expensive equipment.


2006 ◽  
Vol 16 (6) ◽  
pp. 673-686 ◽  
Author(s):  
Laszlo E. Kollar ◽  
Masoud Farzaneh ◽  
Anatolij R. Karev

Author(s):  
Jian Wang ◽  
Jichuan Wu ◽  
Shouqi Yuan ◽  
Wei-Cheng Yan

Abstract Previous work showed that particle behaviors in ultrasonic atomization pyrolysis (UAP) reactor have a great influence on the transport and collection of particles. In this study, the effects of droplet behaviors (i.e. droplet collision and breakage) and solvent evaporation on the droplet size, flow field and collection efficiency during the preparation of ZnO particles by UAP were investigated. The collision, breakage and solvent evaporation conditions which affect the droplet size distribution and flow pattern were considered in CFD simulation based on Eulerian-Lagrangian method. The results showed that droplet collision and breakage would increase the droplet size, broaden the droplet size distribution and hinder the transport of droplets. Solvent evaporation obviously changed the flow pattern of droplets. In addition, both droplet behaviors and solvent evaporation reduced the collection efficiency. This study could provide detail information for better understanding the effect of droplet behaviors and solvent evaporation on the particle production process via UAP reactor.


2014 ◽  
Vol 32 (14) ◽  
pp. 1655-1663 ◽  
Author(s):  
Leila Kavoshi ◽  
Mohammad S. Hatamipour ◽  
Amir Rahimi ◽  
Mehdi Momeni

2004 ◽  
Vol 4 (5) ◽  
pp. 1255-1263 ◽  
Author(s):  
B. Mayer ◽  
M. Schröder ◽  
R. Preusker ◽  
L. Schüller

Abstract. Cloud single scattering properties are mainly determined by the effective radius of the droplet size distribution. There are only few exceptions where the shape of the size distribution affects the optical properties, in particular the rainbow and the glory directions of the scattering phase function. Using observations by the Compact Airborne Spectrographic Imager (CASI) in 180° backscatter geometry, we found that high angular resolution aircraft observations of the glory provide unique new information which is not available from traditional remote sensing techniques: Using only one single wavelength, 753nm, we were able to determine not only optical thickness and effective radius, but also the width of the size distribution at cloud top. Applying this novel technique to the ACE-2 CLOUDYCOLUMN experiment, we found that the size distributions were much narrower than usually assumed in radiation calculations which is in agreement with in-situ observations during this campaign. While the shape of the size distribution has only little relevance for the radiative properties of clouds, it is extremely important for understanding their formation and evolution.


Sign in / Sign up

Export Citation Format

Share Document