Determination of Trace Bromate in Drinking Water with High Chloride Matrix by Cyclic Ion Chromatography

Author(s):  
Mingli Ye ◽  
Pavel N Nesterenko ◽  
Ying Lu ◽  
Xueting Huang ◽  
Xiaoling Jin ◽  
...  

Abstract An ion chromatography (IC) system with switching recycling column was developed for the determination of bromate in drinking water with high chloride content. The system included a pump, two switching valves, guard column and analytical column, suppressor and a conductivity detector. In this method, the single eluent was used for both online collection and matrix elimination, and bromate was eluted from the concentrator column to the analytical column circularly. Under the optimized separation conditions, the method showed good linearity (r = 0.9995) in the range of 1–100 μg/L and repeatability (RSD ≤ 4.80%, n = 6). The limit of detection was 0.2 μg/L (S/N = 3) with 1000 μL sample volume injections. The method was applied to analysis of drinking and tap waters, and satisfactory recoveries of spiked samples between 96.8% and 108.7% were obtained. The result showed that the recycling column-switching system can be useful for the determination of traces of bromate in high-chloride samples, which is required in production of the drinking water and quality control of the final product.

2017 ◽  
Vol 51 (3) ◽  
pp. 43-47
Author(s):  
Meilan Chen ◽  
Jiasheng Yu ◽  
Mingli Ye ◽  
Weiqiang Guo

AbstractAn ion chromatograph single-pump column-switching system was developed for the determination of ammonium in high salt matrices. The simple system included a pump, a suppressor, two valves, two columns, a single eluent, and a conductivity detector. Using this method, both online collection and matrix elimination were achieved. Ammonium was eluted from the acceptor loop to the analytical column circularly. Under the optimized separation conditions, the method showed good linearity (r = 0.9997) in the range of 0.05‐2.0 mg/L and satisfactory repeatability (RSD < 4%, n = 6). The limit of detection was 4 μg/L (S/N = 3) with 25 μl injection. The utilization of the method was demonstrated by the analysis of seawater, with satisfactory spiked recoveries of ammonium between 98.8% and 108.7%. The result showed that the single-pump column-switching system was convenient and practical for the determination of low-level ammonium in high-salinity samples.


2015 ◽  
Vol 7 (6) ◽  
pp. 2830-2838 ◽  
Author(s):  
Shuifeng Zhang ◽  
Liying Huang ◽  
Hongyan Li ◽  
Xiaozhen Chen ◽  
Fengli Wang ◽  
...  

The column-switching system allows for convenient determination and calibration of STW parameters.


2003 ◽  
Vol 1003 (1-2) ◽  
pp. 133-141 ◽  
Author(s):  
P Bruno ◽  
M Caselli ◽  
G de Gennaro ◽  
B De Tommaso ◽  
G Lastella ◽  
...  

2013 ◽  
Vol 40 (11) ◽  
pp. 1703-1708
Author(s):  
Zhong-Yang HU ◽  
Ming-Li YE ◽  
Shu-Chao WU ◽  
Guang-Wen PAN ◽  
Ting-Ting ZHANG ◽  
...  

2012 ◽  
Vol 1265 ◽  
pp. 186-190 ◽  
Author(s):  
Ruiqi Wang ◽  
Nani Wang ◽  
Mingli Ye ◽  
Yan Zhu

2010 ◽  
Vol 48 (7) ◽  
pp. 553-558 ◽  
Author(s):  
H. Zhu ◽  
H. Chen ◽  
Y. Zhong ◽  
D. Ren ◽  
Y. Qian ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document