Identification of circumferential pulmonary vein isolation responders among patients with persistent atrial fibrillation: clinical value of the sequential low-dose ibutilide test

EP Europace ◽  
2020 ◽  
Vol 22 (8) ◽  
pp. 1197-1205
Author(s):  
Shu-Nan He ◽  
Ying Tian ◽  
Liang Shi ◽  
Yan-Jiang Wang ◽  
Bo-Qia Xie ◽  
...  

Abstract Aims Circumferential pulmonary vein isolation can be effective as sole treatment for persistent atrial fibrillation. However, identifying those patients who will respond to this therapy remains a challenge. We investigated the clinical value of the sequential low-dose ibutilide test for identifying patients with persistent atrial fibrillation in whom pulmonary vein isolation is effective as sole therapy. Methods and results In a prospective cohort of 180 consecutive patients with persistent atrial fibrillation, intravenous low-dose (0.004 mg/kg) ibutilide was administered 3 days before ablation and after the completion of circumferential pulmonary vein isolation. In patients in whom ibutilide did not terminate atrial fibrillation pre-procedurally, but successfully terminated it intraprocedurally, no further atrial substrate modification was performed. Pre-procedural low-dose ibutilide failed to terminate the arrhythmia in all patients with persistent atrial fibrillation, while pulmonary vein isolation ± low-dose ibutilide terminated persistent atrial fibrillation in 55 (30.6%) of them (PsAF group 1). The remaining 125 (69.4%) patients underwent electrogram-based ablation (PsAF Group 2). The control group comprised 379 consecutive patients with paroxysmal atrial fibrillation who underwent pulmonary vein isolation over the same period. At 24 months follow-up, 39 (70.9%) patients in PsAF Group 1 and 276 (72.8%) patients in the control group were free from atrial tachyarrhythmias (P = NS); the arrhythmia-free rates in both groups were higher than that in PsAF group 2 (58.4%, P = 0.005). Conclusion The sequential low-dose ibutilide test is a simple method for identifying patients with persistent atrial fibrillation in whom pulmonary vein isolation alone is an appropriate treatment strategy.

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
A Di Cori ◽  
L Segreti ◽  
G Zucchelli ◽  
S Viani ◽  
F Tarasco ◽  
...  

Abstract Background Contact force catheter ablation is the gold standard for treatment of atrial fibrillation (AF). Local tissue impedance (LI) evaluation has been recently studied to evaluate lesion formation during radiofrequency ablation. Purpose Aim of the study was to assess the outcomes of an irrigated catether with LI alghorithm compared to contact force (CF)-sensing catheters in the treatment of symptomatic AF. Methods A prospective, single-center, nonrandomized study was conducted, to compare outcomes between CF-AF ablation (Group 1) and LI-AF ablation (Group 2). For Group 1 ablation was performed using the Carto 3© System with the SmartTouch SF catheter and, as ablation target, an ablation index value of 500 anterior and 400 posterior. For Group 2, ablation was performed using the Rhythmia™ System with novel ablation catheter with a dedicated algorithm (DirectSense) used to measure LI at the distal electrode of this catheter. An absolute impedance drop greater than 20Ω was used at each targeted. According to the Close Protocol, ablation included a point by point pulmonary vein isolation (PVI) with an Inter-lesion space ≤5 mm in both Groups. Procedural endpoint was PVI, with confirmed bidirectional block. Results A total of 116 patients were enrolled, 59 patients in Group 1 (CF) and 57 in Group 2 (LI), 65 (63%) with a paroxismal AF and 36 (37%) with a persistent AF. Baseline patients features were not different between groups (P=ns). LI-Group showed a comparable procedural time (180±89 vs 180±56, P=0.59) but with a longer fluoroscopy time (20±12 vs 13±9 min, P=0.002). Wide antral isolation was more often observed in CF-Group (95% vs 80%, P=0.022), while LI-Group 2 required frequently additional right or left carina ablation (28% vs 14%, P=0.013). The mean LI was 106±14Ω prior to ablation and 92.5±11Ω after ablation (mean LI drop of 13.5±8Ω) during a median RF time of 26 [19–34] sec for each ablation spot. No steam pops or complications during the procedures were reported. The acute procedural success was 100%, with all PVs successfully isolated in all study patients. Regarding safety, only minor vascular complications were observed (5%), without differences between groups (p=0.97). During follow up, 9-month freedom from atrial fibrillation/atrial flutter/atrial tachycardia recurrence was 86% in Group 1 and 75% in Group 2 (P=0.2). Conclusions An LI-guided PV ablation strategy seems to be safe and effective, with acute and mid-term outcomes comparable to the current contact force strategy. LI monitoring could be a promising complementary parameter to evaluate not only wall contact but also lesion formation during power delivery. Procedural Outcomes Funding Acknowledgement Type of funding source: None


Author(s):  
Yi-wei Lai ◽  
Xiaoxia Liu ◽  
Caihua Sang ◽  
Deyong Long ◽  
Mengmeng Li ◽  
...  

Abstract Introduction: Linear ablation in addition to pulmonary vein antrum isolation (PVAI) has failed to improve the success rate for persistent atrial fibrillation (PeAF), due to incomplete block of ablation lines, especially in the mitral isthmus (MI). Methods and results: The study enrolled 191 patients (66 in group 1 and 125 in group 2). In group 1, EI-VOM was firstly performed, followed by radiofrequency (RF) applications targeting bilateral PVAI and bidirectional block in the roofline, cavotricuspid isthmus, and MI. In group 2, PVAI and the three linear ablations were completed using only RF energy. MI block was achieved in 63(95.5%) and 101(80.8%) patients in group 1 and 2, respectively (p=0.006). Patients in group 1 had shorter ablation time for left pulmonary vein antrum (8.15 min vs 12.59 min, p<0.001) and MI (7.0 min vs 11.8 min, p<0.001) and required less cardioversion (50(78.5%) vs 113(90.4%), p=0.007). During the 12-month follow-up, 58 (87.9%) patients were free from AF/AT in group 1 compared with 81 (64.8%) in group 2 (p<0.001). In multivariate cox regression, the ‘upgraded 2C3L’ procedure is associated with a lower recurrence rate (HR 0.27, 95%CI 0.12-0.59). Conclusion: Compared with the conventional ‘2C3L’ approach, the ‘upgraded 2C3L’ approach has higher effectiveness for ablation of PeAF.


Sign in / Sign up

Export Citation Format

Share Document