P1129Comparison of Ventricular Tachyarrhythmia Recurrence Between Ischemic Cardiomyopathy and Dilated Cardiomyopathy in Implantable Cardioverter-Defibrillator Recipients for Secondary Prevention

EP Europace ◽  
2018 ◽  
Vol 20 (suppl_1) ◽  
pp. i212-i212
Author(s):  
W Lee ◽  
M C Chen
2021 ◽  
Vol 10 (1) ◽  
Author(s):  
Sem Briongos‐Figuero ◽  
Arcadio García‐Alberola ◽  
Jerónimo Rubio ◽  
José María Segura ◽  
Aníbal Rodríguez ◽  
...  

Background Large‐scale studies describing modern populations using an implantable cardioverter‐defibrillator (ICD) are lacking. We aimed to analyze the incidence of arrhythmia, device interventions, and mortality in a broad spectrum of real‐world ICD patients with different heart disorders. Methods and Results The UMBRELLA study is a prospective, multicenter, nationwide study of contemporary patients using an ICD followed up by remote monitoring, with a blinded review of arrhythmic episodes. From November 2005 to November 2017, 4296 patients were followed up. After 46.6±27.3 months, 16 067 episodes of sustained ventricular arrhythmia occurred in 1344 patients (31.3%). Appropriate ICD therapy occurred in 27.3% of study population. Patients with ischemic cardiomyopathy (hazard ratio [HR], 1.51; 95% CI, 1.29–1.78), dilated cardiomyopathy (HR, 1.28; 95% CI, 1.07–1.53), and valvular heart disease (HR, 1.94; 95% CI, 1.43–2.62) exhibited a higher risk of appropriate ICD therapies, whereas patients with hypertrophic cardiomyopathy (HR, 0.72; 95% CI, 0.54–0.96) and Brugada syndrome (HR, 0.25; 95% CI, 0.14–0.45) showed a lower risk. All‐cause death was 13.4% at follow‐up. Ischemic cardiomyopathy (HR, 3.09; 95% CI, 2.58–5.90), dilated cardiomyopathy (HR, 3.33; 95% CI, 2.18–5.10), and valvular heart disease (HR, 3.97; 95% CI, 2.25–6.99) had the worst prognoses. Delayed high‐rate detection was enabled in 39.7% of patients, and single‐zone programming occurred in 52.6% of primary prevention patients. Both parameters correlated with lower risk of first appropriate ICD therapy, with no excess risk of mortality. The rate of inappropriate shocks at follow‐up was low (6%) and did not differ among type of ICD but was lower in SmartShock‐capable devices. Conclusions Irrespective of the cause, contemporary ICD patients with heart failure–related disorders had a similar risk of ICD life‐saving interventions and death. Current ICD programming recommendations still need to be implemented. Registration URL: https://www.clinicaltrials.gov ; Unique identifier: NTC01561144.


PeerJ ◽  
2018 ◽  
Vol 6 ◽  
pp. e5312 ◽  
Author(s):  
Chih-Yuan Fang ◽  
Huang-Chung Chen ◽  
Yung-Lung Chen ◽  
Tzu-Hsien Tsai ◽  
Kuo-Li Pan ◽  
...  

BackgroundThe use of an implantable cardioverter-defibrillator (ICD) has been established as an effective secondary prevention strategy for ventricular tachycardia (VT)/ventricular fibrillation (VF). However, few reports discuss the difference in clinical predictors for recurrent VT/VF between patients with ischemic cardiomyopathy (ICM) and patients with dilated cardiomyopathy (DCM).MethodsFrom May 2004 to December 2015, 132 consecutive patients who had ICM (n= 94) or DCM (n= 38) and had received ICD implantation for secondary prevention were enrolled in this study. All anti-tachycardia events during follow-up were validated. The clinical characteristics and echocardiographic parameters were obtained for comparison. The incidence of recurrence of VT/VF, cardiovascular mortality, all-cause mortality, the change of left ventricular ejection fraction (LVEF) and LV volume were analyzed.ResultsAt a mean follow-up of 3.62 ± 2.93 years, 34 patients (36.2%) in the ICM group and 22 patients (57.9%) in the DCM group had a recurrence of VT/VF episodes (p= 0.032). The DCM group had a lower LVEF (p= 0.019), a larger LV end-diastolic volume (LVEDV) (p= 0.001), a higher prevalence of LVEDV >158 mL (p= 0.010), and a larger LV end-systolic volume (p= 0.010) than the ICM group. LVEDV >158 mL and no use of angiotensin-converting-enzyme inhibitor/angiotensin receptor blocker were independent predictors of recurrences of VT/VF in ICM patients but not in DCM patients. There were no difference in cardiovascular mortality and all-cause mortality between the ICM and DCM patients.ConclusionThe DCM patients had a higher recurrence rate of VT/VF than did the ICM patients during long-term follow-up. An enlarged LV is an independent predictor of the recurrence of VT/VF in ICM patients receiving ICD for secondary prevention.


Sign in / Sign up

Export Citation Format

Share Document