Intraprocedural endpoints to predict durable pulmonary vein isolation: a randomized trial of four post-ablation techniques

EP Europace ◽  
2019 ◽  
Vol 22 (4) ◽  
pp. 567-575 ◽  
Author(s):  
Ruhong Jiang ◽  
Minglong Chen ◽  
Bing Yang ◽  
Qiang Liu ◽  
Zuwen Zhang ◽  
...  

Abstract Aims The optimal procedural endpoint to achieve permanent pulmonary vein isolation (PVI) during ablation of atrial fibrillation (AF) remains unknown. We aimed to compare the impact of prolonged waiting periods and adenosine triphosphate (ATP) testing after PVI on long-term freedom from AF. Methods and results In total, 538 patients (median age 61 years, 62% male) undergoing first-time radiofrequency ablation for paroxysmal AF were randomized into four groups: Group 1 [PVI (no testing), n = 121], Group 2 (PVI + 30min waiting phase, n = 151), Group 3 (PVI+ATP, n = 131), and Group 4 (PVI + 30min+ATP, n = 135). The primary endpoint was freedom from AF. Repeat mapping to assess for late pulmonary vein (PV) reconnection was performed in patients who remained AF-free for >3 years (n = 46) and in those who had repeat ablation for AF recurrence (n = 82). During initial procedure, acute PV reconnection was observed in 33%, 26%, and 42% of patients in Groups 2, 3, and 4, respectively. At 36 months, no significant differences in freedom from AF recurrence were observed among all four groups (55%, 61%, 50%, and 62% for Groups 1, 2, 3, and 4, respectively; P = 0.258). Late PV reconnection was commonly observed, with a similar incidence between patients with and without AF recurrence (74% vs. 83%; P = 0.224). Conclusion Although PVI remains the cornerstone for AF ablation, intraprocedural techniques to assess for PV reconnection did not improve long-term success. Patients without AF recurrence after 3 years exhibited similarly high rates of PV reconnection as those that underwent repeat ablation for AF recurrence. The therapeutic mechanisms of AF ablation may not be solely predicated upon durable PVI.

2021 ◽  
Vol 42 (Supplement_1) ◽  
Author(s):  
M Saberito ◽  
N Milstein ◽  
A Bhatt ◽  
M Habibi ◽  
T Sichrovsky ◽  
...  

Abstract Background At time of cryoballoon (CB) pulmonary vein isolation (PVI), some patients with atrial fibrillation (AF) are on an antiarrhythmic drug (AAD) while others are not. The impact of AAD use at time of CB PVI on the duration of post-ablation blanking period (BP) is unknown. Objective To determine whether the optimal BP duration differs between pts who were and were not taking an AAD at time of CB PVI. Methods We enrolled consecutive pts with AF who had initial CB PVI; all pts had an implantable loop recorder (ILR). We prospectively followed all pts and determined the time to last AF episode during the 90-day post-PVI BP. This was then correlated with likelihood of having an AF recurrence between 3–12 months post-PVI. Results The cohort included 165 pts (66±9 years; 99 [60%] male; 91 [55%] PAF; CHA2DS2-VASc 2.7±1.6). An AAD was being used at some point prior to ablation in 120 (73%) pts. An AAD was being used at time of CB PVI in 92 (77%) of these 120 pts; this was stopped at a median of 80 [36, 105] days post-PVI. We defined 4 distinct groups: (1) no AF in 90-day BP (n=75 [45%]); (2) last AF within 30 days of PVI (n=32 [19%]); (3) last AF within 60 days of PVI (n=17 [10%]); and (4) last AF within 90 days of PVI (n=41 [25%]). Patients not exposed to an AAD prior to CB PVI had significantly lower likelihood of having no AF in the first 90-days post ablation (p=0.004, Figure). In contrast, if AF was observed post-ablation, as time from ablation to recurrence increased, so did likelihood of long-term failure from ablation (Figure); this relationship was not impacted by use of an AAD. Conclusion The best long-term outcomes post CB PVI are seen in pts who had no prior exposure to an AAD and had no AF within the first 90 days of ablation. Subsequently, as the time from ablation to AF recurrence increased within the 90-day BP, so did likelihood of recurrent AF during long-term follow-up, irrespective of whether an AAD was or was not used. FUNDunding Acknowledgement Type of funding sources: None.


Author(s):  
Nándor Szegedi ◽  
Milán Vecsey-Nagy ◽  
Judit Simon ◽  
Bálint Szilveszter ◽  
Szilvia Herczeg ◽  
...  

Abstract Aims Controversial results have been published regarding the influence of pulmonary vein (PV) anatomical variations on outcomes after pulmonary vein isolation (PVI). However, no data are available on the impact of PV orientation on the long-term success rates of point-by-point PVI. We sought to determine the impact of PV anatomy and orientation on atrial fibrillation (AF)-free survival in patients undergoing PVI using the radiofrequency point-by-point technique. Methods and results We retrospectively included 448 patients who underwent initial point-by-point radiofrequency ablation for AF at our department. Left atrial computed tomography angiography was performed before each procedure. PV anatomical variations, ostial parameters (area, effective diameter, and eccentricity), orientation, and their associations with 24-month AF-free survival were analysed. PV anatomical variations and ostial parameters were not predictive for AF-free survival (all P > 0.05). Univariate analysis showed that female sex (P = 0.025) was associated with higher rates of AF recurrence, ventral-caudal (P = 0.002), dorsal-cranial (P = 0.034), and dorsal-caudal (P = 0.042) orientation of the right superior PV (RSPV), on the other hand, showed an association with lower rates of AF recurrence, when compared with the reference ventral-cranial orientation. On multivariate analysis, both female sex [odds ratio (OR) 1.83, 95% CI 1.15–2.93, P = 0.011] and ventral-caudal RSPV orientation, compared with ventral-cranial orientation, proved to be independent predictors of 24-month AF recurrence (OR 0.37, 95% CI 0.19–0.71, P = 0.003). Conclusion Female sex and ventral-caudal RSPV orientation have an impact on long-term arrhythmia-free survival. Assessment of PV orientation may be a useful tool in predicting AF-free survival and may contribute to a more personalized management of AF.


2021 ◽  
Vol 22 (Supplement_3) ◽  
Author(s):  
M Vecsey-Nagy ◽  
N Szegedi ◽  
J Simon ◽  
B Szilveszter ◽  
M Kolossvary ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Aims Controversial results have been published regarding the influence of pulmonary vein (PV) anatomical variations on outcomes after pulmonary vein isolation (PVI). However, no data is available on the impact of PV orientation on the long-term success rates of point-by-point PVI. We sought to determine the impact of PV anatomy and orientation on atrial fibrillation (AF)-free survival in patients undergoing PVI using the radiofrequency point-by-point technique. Methods and results We retrospectively included 448 patients who underwent initial point-by-point radiofrequency ablation for AF at our department. Left atrial CT-angiography (CTA) was performed before each procedure. PV anatomical variations, ostial parameters (area, effective diameter and eccentricity), orientation and their associations with 24-month AF-free survival were analyzed. PV anatomical variations and ostial parameters were not predictive for AF-free survival (all p > 0.05). Univariate analysis showed that female sex (p = 0.025) was associated with higher rates of AF recurrence, ventral-caudal (p = 0.002), dorsal-cranial (p = 0.034) and dorsal-caudal (p = 0.042) orientation of the right superior PV (RSPV), on the other hand, showed an association with lower rates of AF recurrence, as compared to the reference ventral-cranial orientation. On multivariate analysis, both female sex [odds ratio(OR) 1.83, 95% CI 1.15-2.93, p = 0.011] and ventral-caudal RSPV orientation, compared with ventral-cranial orientation, proved to be independent predictors of 24-month AF recurrence (OR 0.37, 95% CI 0.19-0.71, p = 0.003). Conclusion   Female sex and ventral-caudal RSPV orientation have an impact on long-term arrhythmia-free survival. Assessment of PV orientation may be a useful tool in predicting AF-free survival and may contribute to a more personalized management of AF.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
A Di Cori ◽  
L Segreti ◽  
G Zucchelli ◽  
S Viani ◽  
F Tarasco ◽  
...  

Abstract Background Contact force catheter ablation is the gold standard for treatment of atrial fibrillation (AF). Local tissue impedance (LI) evaluation has been recently studied to evaluate lesion formation during radiofrequency ablation. Purpose Aim of the study was to assess the outcomes of an irrigated catether with LI alghorithm compared to contact force (CF)-sensing catheters in the treatment of symptomatic AF. Methods A prospective, single-center, nonrandomized study was conducted, to compare outcomes between CF-AF ablation (Group 1) and LI-AF ablation (Group 2). For Group 1 ablation was performed using the Carto 3© System with the SmartTouch SF catheter and, as ablation target, an ablation index value of 500 anterior and 400 posterior. For Group 2, ablation was performed using the Rhythmia™ System with novel ablation catheter with a dedicated algorithm (DirectSense) used to measure LI at the distal electrode of this catheter. An absolute impedance drop greater than 20Ω was used at each targeted. According to the Close Protocol, ablation included a point by point pulmonary vein isolation (PVI) with an Inter-lesion space ≤5 mm in both Groups. Procedural endpoint was PVI, with confirmed bidirectional block. Results A total of 116 patients were enrolled, 59 patients in Group 1 (CF) and 57 in Group 2 (LI), 65 (63%) with a paroxismal AF and 36 (37%) with a persistent AF. Baseline patients features were not different between groups (P=ns). LI-Group showed a comparable procedural time (180±89 vs 180±56, P=0.59) but with a longer fluoroscopy time (20±12 vs 13±9 min, P=0.002). Wide antral isolation was more often observed in CF-Group (95% vs 80%, P=0.022), while LI-Group 2 required frequently additional right or left carina ablation (28% vs 14%, P=0.013). The mean LI was 106±14Ω prior to ablation and 92.5±11Ω after ablation (mean LI drop of 13.5±8Ω) during a median RF time of 26 [19–34] sec for each ablation spot. No steam pops or complications during the procedures were reported. The acute procedural success was 100%, with all PVs successfully isolated in all study patients. Regarding safety, only minor vascular complications were observed (5%), without differences between groups (p=0.97). During follow up, 9-month freedom from atrial fibrillation/atrial flutter/atrial tachycardia recurrence was 86% in Group 1 and 75% in Group 2 (P=0.2). Conclusions An LI-guided PV ablation strategy seems to be safe and effective, with acute and mid-term outcomes comparable to the current contact force strategy. LI monitoring could be a promising complementary parameter to evaluate not only wall contact but also lesion formation during power delivery. Procedural Outcomes Funding Acknowledgement Type of funding source: None


2021 ◽  
Vol 27 (3) ◽  
pp. 55-68
Author(s):  
Svetla Dineva ◽  
Milko Stoyanov ◽  
Aneliya Partenova ◽  
Boyan Kunev ◽  
Victoria Stoyanova ◽  
...  

Anatomical variants of pulmonary venous drainage in the left atrium are often found. Divergent results have been reported on the impact of variant anatomy on atrial fi brillation (AF) recurrence after catheter ablation. We aimed to study the frequency of different anatomical variants of pulmonary venous drainage and their relationship with documented recurrences of AF after ablation. Material and methods: A retrospective study of patients with AF in whom radiofrequency pulmonary vein isolation was done after previously performed cardiac contrast-enhanced multidetector computed tomography. Clinical and procedural characteristics, type and frequency of anatomical variants of the veno-atrial junction and their association with AF recurrences were studied. Results: One hundred seventy-seven patients (112 men, 63.3%) with AF were studied, of which 148 (83.6%) with paroxysmal AF. Variant anatomy was found in 91 patients (51.4%). In 20.9% there was a common left trunk, in 23.2% – more or less than two right-sided veins, and in 7.3% – variations for both right and left veins. No differences in clinical and procedural characteristics were found between the groups with normal and variant anatomy. Recurrences of AF and their association with pulmonary venous anatomy were studied in 104 patients with follow-up ≥ 3 months. No signifi cant relation was found between the presence of variant anatomy and AF recurrences within the blinding period after ablation, OR = 0.864, 95% CI = 0.397 – 1.88, p = 0.843, nor afterwards, OR = 1.12, 95% CI = 0.5 – 2.5, p = 0.839. Cox regression analysis showed no differences in AF recurrence-free survival regardless of the anatomical variant of pulmonary venous drainage, HR = 1.09, 95% CI = 0.58 – 2.05, p = 0.779. Conclusion: In this local population of patients with AF, the incidence of variant pulmonary venous drainage is just over 50%. No association was found between variant anatomy and the rate of AF recurrences after fi rst pulmonary vein isolation.


Circulation ◽  
2020 ◽  
Vol 142 (Suppl_3) ◽  
Author(s):  
Dan L Musat ◽  
Nicolle S Milstein ◽  
Jacqueline Pimienta ◽  
Advay Bhatt ◽  
Tina C Sichrovsky ◽  
...  

Background: Pulmonary vein isolation (PVI) is a cornerstone of atrial fibrillation (AF) ablation procedures to treat symptomatic AF. Ablation success is defined by absence of AF recurrence >30 seconds. However, reduction in AF burden (AFB) is also an important endpoint. Whether patients with paroxysmal (PAF) and persistent AF (PeAF) have similar reduction in AFB post-ablation is unknown. Objective: To compare the decrease in AFB following cryoballoon (CB) PVI in patients with PAF and PeAF. Methods: We enrolled consecutive pts with an implantable loop recorder (ILR) who subsequently underwent CB PVI. All patients were followed prospectively for at least one year, or until repeat ablation; we compared AFB pre and post-ablation. Results: The cohort included had 47 patients (66 ± 10 years; 32 [68%] male; PAF [n=23, 49%]; CHA 2 DS 2 -VASc 2.7 ± 1.7, 34 [72%] on AAD at the time of ablation). A median of 136 days [IQR 280, 73; minimum of 30 days] of ILR data pre-ablation were available. The median AFB for PAF was 4.7% [IQR 0.9, 14.8] and PeAF was 6.8% [IQR 1.1, 40.4]. After excluding a 3-month post-ablation blanking period, recurrent AF occurred in 12 (52%) PAF and 11 (46%) PeAF patients. The median AFB post-ablation for PAF and PeAF cohorts was 0.03%, [IQR 0, 0.3] and 0.04%, [IQR 0, 1.1], respectively. This represents a >99% reduction in AFB. Conclusion: Although 50% of patients undergoing CB PVI for PAF or PeAF had a recurrence of AF, there was >99% reduction in AFB in both groups. These data highlight the importance of using AFB burden as a marker of therapeutic efficacy post-AF ablation.


2016 ◽  
Vol 2016 ◽  
pp. 1-13 ◽  
Author(s):  
Paolo D. Dallaglio ◽  
Timothy R. Betts ◽  
Matthew Ginks ◽  
Yaver Bashir ◽  
Ignasi Anguera ◽  
...  

The cornerstone of atrial fibrillation (AF) ablation is pulmonary vein isolation (PVI), which can be achieved in more than 95% of patients at the end of the procedure. However, AF recurrence rates remain high and are related to recovery of PV conduction. Adenosine testing is used to unmask dormant pulmonary vein conduction (DC). The aim of this study is to review the available literature addressing the role of adenosine testing and determine the impact of ablation at sites of PV reconnection on freedom from AF. Adenosine infusion, by restoring the excitability threshold, unmasks reversible injury that could lead to recovery of PV conduction. The studies included in this review suggest that adenosine is useful to unmask nontransmural lesions at risk of reconnection and that further ablation at sites of DC is associated with improvement in freedom from AF. Nevertheless it has been demonstrated that adenosine is not able to predict all veins at risk of later reconnection, which means that veins without DC are not necessarily at low risk. The role of the waiting period in the setting of adenosine testing has also been analyzed, suggesting that in the acute phase adenosine use should be accompanied by enough waiting time.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
D J Nascimento Matos ◽  
D Cavaco ◽  
G Rodrigues ◽  
J Carmo ◽  
M S Carvalho ◽  
...  

Abstract Introduction Pulmonary vein (PV) reconnection is a common cause of relapse after catheter ablation of atrial fibrillation (AF). However, some patients have AF recurrence despite durable PV isolation. The aim of this study was to assess the PV isolation status at the time of a second catheter ablation (redo) procedure, and its relationship with subsequent AF relapse. Methods Consecutive patients with symptomatic drug-resistant AF who underwent redo procedures from January 2006 to December 2017 were identified in a single-center observational registry. Pulmonary vein isolation status was assessed during the electrophysiologic study with a circular mapping catheter. Additional radiofrequency (RF) energy applications were also recorded. AF relapse was defined as symptomatic or documented AF/atrial tachycardia/atrial flutter after a 3-month blanking period. Results We identified 240 patients (77 [32%] females, median age 61 [IQR 53–67] years, 85 [35%] with non-paroxysmal AF) undergoing redo procedures during the study period. At the time of redo, 17 (7%) of the patients presented bidirectional conduction block of all PVs. PV reconnection occurred in 157 (65%) of cases in the left superior vein, 142 (59%) in the left inferior vein, 177 (73%) in the right superior vein, and 163 (68%) in the right inferior vein (table). All of the PVs were reconducted in 91 (38%) patients. Additional RF applications were performed in the left atrium (LA) roof, LA posterior wall, cavotricuspid isthmus, mitral isthmus, superior vena cava, coronary sinus, and left atrial appendage ostium, at the operator's discretion (table 1). Over a median follow-up of 2-years (IQR 1–5), 126 patients (53%) suffered AF recurrence, yielding a mean relapse rate of 17%/year. In multivariate Cox regression analysis, the lack of PV reconnection at the time of redo emerged as an independent predictor of subsequent relapse (HR 1.97, 95% CI 1.12–3.49, p=0.019) even after adjustment for univariate predictors including non-paroxysmal AF, body mass index, female sex, and active smoking. Conclusion In patients undergoing redo AF ablation procedures, less than 10% present with complete PV isolation. Despite being relatively infrequent, this finding is independently associated with greater likelihood of subsequent recurrence, suggesting that other mechanisms, not fully addressed by additional RF applications, are at play.


2021 ◽  
Vol 10 (3) ◽  
Author(s):  
Leon Dinshaw ◽  
Paula Münkler ◽  
Benjamin Schäffer ◽  
Niklas Klatt ◽  
Christiane Jungen ◽  
...  

Background Atrial fibrillation (AF) is common in patients with hypertrophic cardiomyopathy (HCM) and is associated with a deterioration of clinical status. Ablation of symptomatic AF is an established therapy, but in HCM, the characteristics of recurrent atrial arrhythmias and the long‐term outcome are uncertain. Methods and Results Sixty‐five patients with HCM (aged 64.5±9.9 years, 42 [64.6%] men) underwent AF ablation. The ablation strategy included pulmonary vein isolation in all patients and ablation of complex fractionated atrial electrograms or subsequent atrial tachycardias (AT) if appropriate. Paroxysmal, persistent AF, and a primary AT was present in 13 (20.0%), 51 (78.5%), and 1 (1.5%) patients, respectively. Twenty‐five (38.4%) patients developed AT with a total number of 54 ATs. Stable AT was observed in 15 (23.1%) and unstable AT in 10 (15.3%) patients. The mechanism was characterized as a macroreentry in 37 (68.5%), as a localized reentry in 12 (22.2%), a focal mechanism in 1 (1.9%), and not classified in 4 (7.4%) ATs. After 1.9±1.2 ablation procedures and a follow‐up of 48.1±32.5 months, freedom of AF/AT recurrences was demonstrated in 60.0% of patients. No recurrences occurred in 84.6% and 52.9% of patients with paroxysmal and persistent AF, respectively ( P <0.01). Antiarrhythmic drug therapy was maintained in 24 (36.9%) patients. Conclusions AF ablation in patients with HCM is effective for long‐term rhythm control, and especially patients with paroxysmal AF undergoing pulmonary vein isolation have a good clinical outcome. ATs after AF ablation are frequently observed in HCM. Freedom of atrial arrhythmia is achieved by persistent AF ablation in a reasonable number of patients even though the use of antiarrhythmic drug therapy remains high.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
D Musat ◽  
N Milstein ◽  
R Shaw ◽  
A Bhatt ◽  
M Preminger ◽  
...  

Abstract Background Cryoballoon (CB) pulmonary vein isolation (PVI) is increasingly being used in patients (pts) with persistent atrial fibrillation (AF). However, there are limited data about the pattern of atrial fibrillation (AF) recurrence in these pts. Objective To assess, using an implantable loop recorder (ILR), the patterns of AF recurrence following CB PVI in pts with persistent atrial fibrillation. Methods We enrolled consecutive pts with persistent AF ablation undergoing their first CB ablation. Other cavotricuspid isthmus ablation when indicated, no other ablation was performed. A Reveal LINQ ILR (Medtronic) was implanted <3 months following ablation; all pts had a minimum of 1-year follow-up. The recurrence of any atrial arrhythmia was determined and adjudicated; 4 distinct AF patterns were characterized (Figure). Results We studied 64 pts (66±9 years; 50 [78%] male; CHA2DS2-VASc 2.6±1.9) with persistent AF; 52 (81%) pts were on an antiarrhythmic drug (AAD) peri-ablation. During 803±361 days of follow-up, 33 (52%) pts had their 1st AF recurrence 91–365 days post-ablation and another 17 (27%) pts had their 1st AF recurrence >365 days post-ablation. No AF was seen in 14 (31%) pts. Most pts (33 of 50, 66%) with AF recurrence presented with 1 of 3 distinct patterns of paroxysmal AF (Figure), which ranged from 22 min to 124 hours. In 2/3 of these pts, all AF recurrences lasted <24 hours. Only 17 (34%) pts recurred with persistent AF. Conclusion Following single CB PVI, most pts with persistent AF remained free of persistent AF during long-term follow-up. Most pts with recurrent AF have 1 of 3 distinct patterns with episodes commonly last <24 hours. These data suggest that CB PVI ablation may halt AF progression in pts initially presenting with persistent AF.


Sign in / Sign up

Export Citation Format

Share Document