Collaborative Study of a Method for Determination of Monosodium Glutamate in Food Products

1969 ◽  
Vol 52 (6) ◽  
pp. 1131-1132
Author(s):  
E Fernandez-Flores ◽  
Arthur R Johnson ◽  
Victor H Blomquist

Abstract A method was collaboratively studied for the determination of monosodium glutamate as glutamic acid in food products. Six samples were submitted to each of nine collaborators. The quantity of monosodium glutamate in the samples ranged from 0.3 to 10%. The average recovery was 101.9% with a standard deviation of 3.6%. The method is recommended for adoption as official first action.

1972 ◽  
Vol 55 (1) ◽  
pp. 163-165
Author(s):  
Dalia M Gilvydis

Abstract Dichlorophene is determined in veterinary preparations by a liquid-liquid extraction and UV quantitation. Eight collaborators each analyzed 4 commercial preparations and one synthetic mixture. The average recovery for dichlorophene in the synthetic mixture is 100.3% with a standard deviation of 2.13. The standard deviations obtained for the 5 samples range from 0.13 to 3.69 with coefficients of variation from 0.69 to 3.43. It is recommended that the method be adopted as official first action.


1995 ◽  
Vol 78 (2) ◽  
pp. 301-306 ◽  
Author(s):  
Kristi A Boehm ◽  
P Frank Ross

Abstract Twelve collaborating laboratories analyzed 5 blind duplicate samples of human urine for total nitrogen using a pyrochemiluminescence method. The nitrogen content ranged from low (650 mg/L) to high levels (8800 mg/L) in urine samples of people under moderate to severe stress. In addition to test samples, collaborators also received a certified standard (sodium nitrite in water) as an external control. The pyrochemiluminescence assay was performed on urine samples diluted in water within a range of 1:50 to 1:100. The method detects total nitrogen by reaction of the product of high temperature oxidative pyrolysis and ozone. Repeatability standard deviation values (RDSr) ranged from 1.49 to 3.91% and reproducibility standard deviation values (RSDR) ranged from 3.66 to 9.57%. The average recovery of total nitrogen was 99.9%. The pyrochemiluminescence method for determination of total nitrogen in urine was adopted first action by AOAC INTERNATIONAL.


1975 ◽  
Vol 58 (1) ◽  
pp. 58-61 ◽  
Author(s):  
Elia D Coppola ◽  
Spence N Christie ◽  
J Gordon Coppola

Abstract In a simple and fast procedure, monosodium glutamate in food products is first separated by a short ion exchange column and subsequently determined fluorometrically with fluorescamine. An average recovery of 90.8% with a standard deviation of ±6.67% was obtained for added monosodium glutamate in a series of 8 products. As little as 0.05% monosodium glutamate can be determined. The method is faster than the official method and saves 5 hr/ determination.


1971 ◽  
Vol 54 (3) ◽  
pp. 603-608
Author(s):  
Rod Chu

Abstract A method for the assay of methyldopa with either chlorothiazide or hydrochlorothiazide was studied collaboratively by 8 laboratories. The method involves the use of AG50-4X, 100-200 mesh H+ cation exchange resin to resolve the compounds. The thiazides pass freely through the resin column, while methyldopa is retained and subsequently eluted with 1N methanolic HCl. The components are quantitatively measured by spectrophotometry at 280 (methyldopa), 277 (chlorothiazide), and 270 nm (hydrochlorothiazide). For the methyldopa-chlorothiazide combination, the overall average recovery for methyldopa was 98.5% with a standard deviation of 2.50; and for the methyldopa-hydrochlorothiazide combination, 96.4% with a standard deviation of 2.30. The average recoveries for chlorothiazide and hydrochlorothiazide were 99.6 (standard deviation of 1.14) and 98.8% (standard deviation of 2.92), respectively. The method has been adopted as official first action for the determination of methyldopa and chlorothiazide in combination.


1983 ◽  
Vol 66 (6) ◽  
pp. 1528-1531 ◽  
Author(s):  
Hiroshi Nakanishi

Abstract A gas chromatographic procedure is described for determining monosodium glutamate (MSG) in several types of food. A sample is extracted with acetone- water (1 + 1). Acetone is evaporated and an aliquot of the extract is buffered with 1M NH4OH-1M NH4CI pH 9 solution, and chromatographed directly on a column of QAE Sephadex A-25 that has been pretreated with the same buffer. MSG is eluted with 0.1N HC1, and a portion of the eluate is evaporated to dryness and reacted with dimethylformamide( DMF)-dimethylacetal to form the glutamic acid derivative, which is injected into a gas chromatograph and measured by flame ionization detection. Recoveries of MSG from sample fortified at 5-500 mg ranged from 92.8 to 100%.


1998 ◽  
Vol 81 (4) ◽  
pp. 763-774 ◽  
Author(s):  
Joanna M Lynch ◽  
David M Barbano ◽  
J Richard Fleming

Abstract The classic method for determination of milk casein is based on precipitation of casein at pH 4.6. Precipitated milk casein is removed by filtration and the nitrogen content of either the precipitate (direct casein method) or filtrate (noncasein nitrogen; NCN) is determined by Kjeldahl analysis. For the indirect casein method, milk total nitrogen (TN; Method 991.20) is also determined and casein is calculated as TN minus NCN. Ten laboratories tested 9 pairs of blind duplicate raw milk materials with a casein range of 2.42- 3.05℅ by both the direct and indirect casein methods. Statistical performance expressed in protein equivalents (nitrogen ⨯ 6.38) with invalid and outlier data removed was as follows: NCN method (wt%), mean = 0.762, sr = 0.010, SR = 0.016, repeatability relative standard deviation (RSDr) = 1.287℅, reproducibility relative standard deviation (RSDR) = 2.146%; indirect casein method (wt℅), mean = 2.585, repeatability = 0.015, reproducibility = 0.022, RSDr = 0.560℅, RSDR = 0.841; direct casein method (wt℅), mean = 2.575, sr = 0.015, sR = 0.025, RSDr = 0.597℅, RSDR = 0.988℅. Method performance was acceptable and comparable to similar Kjeldahl methods for determining nitrogen content of milk (Methods 991.20, 991.21,991.22, 991.23). The direct casein, indirect casein, and noncasein nitrogen methods have been adopted by AOAC INTERNATIONAL.


2013 ◽  
Vol 10 (3) ◽  
pp. 1005-1013 ◽  
Author(s):  
Baghdad Science Journal

A simple, accurate, precise, rapid, economical and a high sensitive spectrophotometric method has been developed for the determination of tadalafil in pharmaceutical preparations and industrial wastewater samples, which shows a maximum absorbance at 204 nm in 1:1 ethanol-water. Beer's law was obeyed in the range of 1-7?g/ mL ,with molar absorptivity and Sandell ? s sensitivity of 0.783x105l/mol.cm and 4.97 ng/cm2respectively, relative standard deviation of the method was less than 1.7%, and accuracy (average recovery %) was 100 ± 0. 13. The limits of detection and quantitation are 0.18 and 0.54 µg .ml-1, respectively. The method was successfully applied to the determination of tadalafil in some pharmaceutical formulations (tablets) and industrial wastewater samples. The proposed method was validated by sensitivity and precision which proves suitability for the routine analysis of tadalafil in true samples.


1975 ◽  
Vol 58 (2) ◽  
pp. 258-262 ◽  
Author(s):  
Colette P Levi

Abstract A method for the semiquantitative determination of ochratoxin A in green coffee has been studied collaboratively by 11 laboratories. The average recovery for the 7 samples spiked at 3 levels of ochratoxin A was 69.1%, ranging from 60.5 to 85.6%. This is comparable to other visual thin layer chromatographic methods of mycotoxin detection. The method has been adopted as official first action for the determination of ochratoxin A in green coffee beans.


1973 ◽  
Vol 56 (5) ◽  
pp. 1164-1172
Author(s):  
Milan Ihnat ◽  
Robert J Westerby ◽  
Israel Hoffman

Abstract The distillation-spectrophotometric method of Hoffman for determining maleic hydrazide has been modified to include a double distillation and was applied to the determination of 1–30 ppm maleic hydrazide residues in tobacco and vegetables. Recoveries of 1–23 μg added maleic hydrazide were independent of weight of maleic hydrazide, but did depend on sample and sample weight. The following recoveries were obtained from 0.5 g sample: pipe tobacco, 84%; commercially dehydrated potato, 83%; cigar tobacco, 81%; dried potato, 76%; fluecured tobacco, 73%; dried carrot, 71%. In the absence of sample, the recovery was 82%. When appropriate standard curves were used, maleic hydrazide levels determined in tobacco samples were essentially independent of sample weight in the range 0.1–3 g. The mean relative standard deviation for a variety of field-treated and fortified tobacco samples containing 1–28 ppm maleic hydrazide was 3%. The precision and sensitivity of this procedure seem to be substantial improvements over official method 29.111–29.117. It is recommended that the present method be subjected to a collaborative study.


2002 ◽  
Vol 85 (4) ◽  
pp. 889-900 ◽  
Author(s):  
Eric Verdon ◽  
Pierric Couëdor ◽  
Pierre Maris ◽  
Michel Laurentie ◽  
P Batjoens ◽  
...  

Abstract A collaborative study involving 14 laboratories was conducted to determine residues of ampicillin in porcine muscle tissue by using a liquid chromatographic method developed for multipenicillin analysis that can quantitate 8 penicillin compounds (benzylpenicillin, phenoxymethylpenicillin, ampicillin, amoxicillin, nafcillin, oxacillin, cloxacillin, and dicloxacillin) at trace levels in muscle tissue. This method involves extraction of the penicillins with phosphate buffer, pH 9, followed cleanup and concentration on a C18 solid-phase extraction column and reaction with benzoic anhydride at 50°C and with 1,2,4-triazole and mercury(II) chloride solution, pH 9.0, at 65°C. The derivatized compounds are eluted isocratically on a C8 column with a mobile phase of acetonitrile and phosphate buffer (pH 6; 0.1M) containing sodium thiosulfate and the ion-pair reagent tetrabutylammonium hydrogen sulfate. The penicillins are detected by UV absorption at 325 nm. The limit of detection and the limit of determination (quantitation) of the method were calculated to be approximately 3–5 and 25 μg/kg, respectively, in accordance with the criteria of European Union (EU) Decision No. 93/256/EEC. In this first interlaboratory study, collaborators were instructed to monitor 4 different penicillin compounds (benzylpenicillin, phenoxymethylpenicillin, ampicillin, and amoxicillin) by analyzing 8 blind samples of muscle tissue in triplicate. These samples were prepared from 2 materials containing different concentrations of incurred ampicillin (63.5 μg/kg for material No. 1 and 358.1 μg/kg for material No. 2) and 1 blank material. The repeatability relative standard deviation and the reproducibility relative standard deviation were 10.2 and 17.4%, respectively, for material No. 1 and 7.0 and 16.0%, respectively, for material No. 2. These results demonstrate that the method is suitable for the determination of ampicillin residues in muscle tissue at the EU maximum residue limit (50 μg/kg) and above. However, the identification of positives by this procedure may need additional confirmation by techniques with greater specificity, such as liquid chromatography combined with mass spectrometry, or tandem mass spectrometry. Investigations regarding the basis of interlaboratory testing studies will further demonstrate the suitability of multiresidue methodology for detecting and quantitating other compounds in the family of penicillin antibiotics.


Sign in / Sign up

Export Citation Format

Share Document