scholarly journals Determination of Norfloxacin and Enrofloxacin by Solid-Phase Microextraction/High-Performance Liquid Chromatography

2008 ◽  
Vol 91 (6) ◽  
pp. 1339-1343 ◽  
Author(s):  
Ashwini Kumar ◽  
Gaurav Dhingra ◽  
Ashok Kumar malik ◽  
Dhananjay K Tewary

Abstract A solid-phase microextraction (SPME) method followed by separation with high-performance liquid chromatography and subsequent UV detection was developed for the determination of norfloxacin and enrofloxacin. The simple and sensitive preconcentration technique uses 280 nm wavelength in mobile phase of citrate buffer (0.01 M), pH 3.8, prepared in water (A) and acetonitrile (B), with composition of the mobile phase A:B, 40:60, at a flow rate of 1.0 mL/min. A C18 reversed-phase analytical column (5 m) was selected as separation medium for the technique. To obtain optimum extraction efficiency, several parameters relating to SPME were investigated. The method was linear over the range of 10100 ng/mL for norfloxacin and enrofloxacin with a correlation coefficient (R2) value of 0.9972 and 0.9980 for norfloxacin and enrofloxacin, respectively. Using the SPME method, the detection limits (signal-to-noise ratio 3) are 0.17 and 0.12 ng/mL for norfloxacin and enrofloxacin, respectively.

1994 ◽  
Vol 59 (3) ◽  
pp. 569-574 ◽  
Author(s):  
Josef Královský ◽  
Marta Kalhousová ◽  
Petr Šlosar

The reversed-phase high-performance liquid chromatography of some selected, industrially important aromatic sulfones has been investigated. The chromatographic behaviour of three groups of aromatic sulfones has been studied. The optimum conditions of separation and UV spectra of the sulfones and some of their hydroxy and benzyloxy derivatives are presented. The dependences of capacity factors vs methanol content in mobile phase are mentioned. The results obtained have been applied to the quantitative analysis of different technical-grade samples and isomer mixtures. For all the separation methods mentioned the concentration ranges of linear calibration curves have been determined.


Author(s):  
Muhammad Fawad Rasool ◽  
Umbreen Fatima Qureshi ◽  
Nazar Muhammad Ranjha ◽  
Imran Imran ◽  
Mouqadus Un Nisa ◽  
...  

AbstractTh accurate rapid, simple and selective reversed phase high performance liquid chromatography (RP-HPLC) has been established and validated for the determination of captopril (CAP). Chromatographic separation was accomplished using prepacked ODSI C18 column (250 mm × 4.6 mm with 5 μm particle size) in isocratic mode, with mobile phase consisting of water: acetonitrile (60:40 v/v), pH adjusted to 2.5 by using 85% orthophosphoric acid at a flow rate of 1 mL/min and UV detection was performed at 203 nm. RP-HPLC method used for the analysis of CAP in mobile phase and rabbit plasma was established and validated as per ICH-guidelines. It was carried out on a well-defined chromatographic peak of CAP was established with a retention time of 4.9 min and tailing factor of 1.871. The liquid–liquid extraction method was used for extraction of CAP from the plasma. Excellent linearity (R2 = 0.999) was shown over range 3.125–100 µg/mL with mean percentage recoveries ranges from 97 to 100.6%. Parameters of precision and accuracy of the developed method meet the established criteria. Intra and inter-day precision (% relative standard deviation) study was also performed which was less than 2% which indicate good reproducibility of the method. The limit of detection (LOD) and quantification for the CAP in plasma were 3.10 and 9.13 ng/mL respectively. The method was suitably validated and successfully applied to the determination of CAP in rabbit plasma samples.


Sign in / Sign up

Export Citation Format

Share Document