Three-dimensional structure analysis of melanocytes and keratinocytes in senile lentigo

Microscopy ◽  
2020 ◽  
Author(s):  
Yuki Mizutani ◽  
Mika Yamashita ◽  
Rie Hashimoto ◽  
Toru Atsugi ◽  
Akemi Ryu ◽  
...  

Abstract Senile lentigo or age spots are hyperpigmented macules of skin that commonly develop following long-term exposure to ultraviolet radiation. This condition is caused by accumulation of large numbers of melanosomes (melanin granules) produced by melanocytes within neighboring keratinocytes. However, there is still no consensus regarding the melanosome transfer mechanism in senile lentigo. To date, most pathohistological studies of skin have been two-dimensional and do not provide detailed data on the complex interactions of the melanocyte–keratinocyte network involved in melanosome transfer. We performed a three-dimensional reconstruction of the epidermal microstructure in senile lentigo using three different microscopic modalities to visualize the topological melanocyte–keratinocyte relationship and melanosome distribution. Confocal laser microscopy images showed that melanocyte dendritic processes are more frequently branched and elongated in senile lentigo skin than in normal skin. Serial transmission electron micrographs showed that dendritic processes extend into intercellular spaces between keratinocytes. Focused ion beam-scanning electron micrographs showed that dendritic processes in senile lentigo encircle adjacent keratinocytes and accumulate large numbers of melanosomes. Moreover, melanosomes transferred to keratinocytes are present not only in the supranuclear area but throughout the perinuclear area except on the basal side. The use of these different microscopic methods helped to elucidate the three-dimensional morphology and topology of melanocytes and keratinocytes in senile lentigo. We show that the localization of melanosomes in dendritic processes to the region encircling recipient keratinocytes contributes to efficient melanosome transfer in senile lentigo.

2007 ◽  
Vol 15 (2) ◽  
pp. 26-31 ◽  
Author(s):  
Ben Lich

DualBeam instruments that combine the imaging capability of scanning electron microscopy (SEM) with the cutting and deposition capability of a focused ion beam (FIB) provide biologists with a powerful tool for investigating three-dimensional structure with nanoscale (1 nm-100 nm) resolution. Ever since Van Leeuwenhoek used the first microscope to describe bacteria more than 300 years ago, microscopy has played a central role in scientists' efforts to understand biological systems. Light microscopy is generally limited to a useful resolution of about a micrometer. More recently the use of confocal and electron microscopy has enabled investigations at higher resolution. Used with fluorescent markers, confocal microscopy can detect and localize molecular scale features, but its imaging resolution is still limited. SEM is capable of nanometer resolution, but is limited to the near surface region of the sample.


2015 ◽  
Vol 12 (3) ◽  
pp. 825-834 ◽  
Author(s):  
R. Hoffmann ◽  
C. Kirchlechner ◽  
G. Langer ◽  
A. S. Wochnik ◽  
E. Griesshaber ◽  
...  

Abstract. Coccospheres of a cultured Emiliania huxleyi clone were sampled in the exponential growth phase and sectioned using a focused ion beam microscope. An average of 69 sections and the corresponding secondary electron micrographs per coccosphere provided detailed information on coccosphere architecture. The coccospheres feature 2–3 layers on average and 20 coccoliths per cell, of which only 15 can be seen in conventional scanning electron micrographs. The outer coccosphere diameter was positively correlated with the number of coccolith layers. By contrast, the inner coccosphere diameter (around 4.36 μm), and hence the cell diameter, was quasi-constant. Coccoliths were not evenly distributed across the coccosphere, resulting more often than not in one part of the coccosphere displaying more coccolith layers than the other. The architectural data allowed for the calculation of the PIC $/$ POC ratio, the density and the sinking velocity of individual cells. The correlation of these parameters has implications for the ongoing debate on the function of coccoliths.


2013 ◽  
Vol 19 (3) ◽  
pp. 745-750 ◽  
Author(s):  
Juan Balach ◽  
Flavio Soldera ◽  
Diego F. Acevedo ◽  
Frank Mücklich ◽  
César A. Barbero

AbstractA new technique that allows direct three-dimensional (3D) investigations of mesopores in carbon materials and quantitative characterization of their physical properties is reported. Focused ion beam nanotomography (FIB-nt) is performed by a serial sectioning procedure with a dual beam FIB-scanning electron microscopy instrument. Mesoporous carbons (MPCs) with tailored mesopore size are produced by carbonization of resorcinol-formaldehyde gels in the presence of a cationic surfactant as a pore stabilizer. A visual 3D morphology representation of disordered porous carbon is shown. Pore size distribution of MPCs is determined by the FIB-nt technique and nitrogen sorption isotherm methods to compare both results. The obtained MPCs exhibit pore sizes of 4.7, 7.2, and 18.3 nm, and a specific surface area of ca. 560 m2/g.


Fuel Cells ◽  
2013 ◽  
Vol 14 (1) ◽  
pp. 91-95 ◽  
Author(s):  
H. Amani Hamedani ◽  
M. Baniassadi ◽  
A. Sheidaei ◽  
F. Pourboghrat ◽  
Y. Rémond ◽  
...  

2016 ◽  
Vol 23 (4) ◽  
pp. 990-996 ◽  
Author(s):  
Christopher E. Shuck ◽  
Mathew Frazee ◽  
Andrew Gillman ◽  
Matthew T. Beason ◽  
Ibrahim Emre Gunduz ◽  
...  

Knowing the relationship between three-dimensional structure and properties is paramount for complete understanding of material behavior. In this work, the internal nanostructure of micrometer-size (∼10 µm) composite Ni/Al particles was analyzed using two different approaches. The first technique, synchrotron-based X-ray nanotomography, is a nondestructive method that can attain resolutions of tens of nanometers. The second is a destructive technique with sub-nanometer resolution utilizing scanning electron microscopy combined with an ion beam and `slice and view' analysis, where the sample is repeatedly milled and imaged. The obtained results suggest that both techniques allow for an accurate characterization of the larger-scale structures, while differences exist in the characterization of the smallest features. Using the Monte Carlo method, the effective resolution of the X-ray nanotomography technique was determined to be ∼48 nm, while focused-ion-beam sectioning with `slice and view' analysis was ∼5 nm.


Sign in / Sign up

Export Citation Format

Share Document