scholarly journals The Feasibility of a Novel Index From a Wireless Doppler Ultrasound Patch to Detect Decreasing Cardiac Output in Healthy Volunteers

2021 ◽  
Vol 186 (Supplement_1) ◽  
pp. 751-756 ◽  
Author(s):  
Jon-Émile S Kenny ◽  
Andrew M Eibl ◽  
Matthew Parrotta ◽  
Bradley F Long ◽  
Joseph K Eibl

ABSTRACT Introduction Early hemorrhage is often missed by traditional vital signs because of physiological reserve, especially in the young and healthy. We have developed a novel, wearable, wireless Doppler ultrasound patch that tracks real-time blood velocity in the common carotid artery. Materials and Methods We studied eight healthy volunteers who decreased their cardiac output using a standardized Valsalva maneuver. In all eight, we simultaneously monitored the velocity time integral (VTI) of the common carotid artery (using the ultrasound patch) as well as the descending aorta (using a traditional pulsed wave duplex imaging system); the descending aortic VTI was used as a surrogate for left ventricular stroke volume (SV). Additionally, in a subset of four, we simultaneously measured SV using a noninvasive pulse contour analysis device. Results From baseline to peak effect of Valsalva, there was a statistically significant fall in descending aortic and common carotid VTI of 37% (P = 0.0005) and 23% (P < 0.0001), respectively. Both values returned to baseline on recovery. Additionally, a novel index from the carotid ultrasound patch (i.e., the heart rate divided by the carotid artery VTI) detected a 10% fall in aortic VTI with high sensitivity and specificity (100% and 100%, respectively); this novel index also accurately detected a 10% decrease in SV as measured by the noninvasive SV monitor. The mean arterial pressure, measured by the noninvasive pulse contour device, did not correctly detect the fall in SV. Conclusion In summary, a novel index from a wireless Doppler ultrasound patch may be more sensitive and specific for detecting decreased cardiac output than standard vital signs in healthy volunteers.

2002 ◽  
Vol 22 (4) ◽  
pp. 477-487 ◽  
Author(s):  
Constantijn J.A.M. Konings ◽  
Jeroen P. Kooman ◽  
Marc Schonck ◽  
Ruben Dammers ◽  
Emiel Cheriex ◽  
...  

♦ Objective Hypertension, reduced arterial distensibility, and left ventricular hypertrophy (LVH) are risk factors for mortality in hemodialysis patients. However, few studies have focused on the relation between fluid status, blood pressure (BP), and cardiovascular abnormalities in peritoneal dialysis (PD) patients. This study was designed, first, to assess, using tracer dilution techniques, fluid status in PD patients compared to a control population of stable renal transplant (RTx) patients; second, to study the relation between fluid status, BP, and arterial wall abnormalities; third, to assess the determinants of cardiac structure; and last, to compare office and ambulatory BP measurements with respect to cardiac abnormalities. ♦ Design Cross-sectional study. ♦ Setting Multicenter study. ♦ Patients 41 stable PD patients with a mean Kt/V urea of 2.4 ± 0.7, and 77 stable RTx patients. ♦ Intervention Fluid status was assessed by tracer dilution techniques: extracellular volume (ECV) with bromide dilution; total body water (TBW) with deuterium oxide; and plasma volume (PV) with dextran 70. Echocardiography was performed to assess left ventricular mass (LVM), left ventricular end diastolic diameter (LVEDD), and relative wall thickness as indicators of LVH. Echography of the common carotid artery was performed to assess arterial distensibility. Both office and 24-hour ambulatory BP measurements were performed. ♦ Results Fluid status, as assessed by ECV corrected for body surface area (BSA) (ECV:BSA), was significantly different between PD and RTx patients (9.4 ± 2.6 vs 8.6 ± 1.2 L/m2, p < 0.05). In 36.6% of the PD patients, ECV:BSA was above the 90th percentile of the RTx patients. Fluid status corrected for BSA, assessed by TBW (TBW:BSA), ECV (ECV:BSA), or plasma volume (PV:BSA), was significantly related to diastolic BP (DBP) ( r = 0.35, r = 0.37, r = 0.53; p < 0.05). Arterial distensibility of the common carotid artery was related to systolic BP (SBP) ( r = –0.36, p < 0.05). ECV was significantly related to LVEDD ( r = 0.41, p < 0.05) as a marker of eccentric LVH, whereas arterial distensibility was related to relative wall thickness ( r = –0.53, p < 0.001) as a marker of concentric LVH. An abnormal day–night BP rhythm, which was not related to fluid status, was observed in 68.4% of patients. Ambulatory DBP and SBP but not office DBP and SBP were related to LVM ( r = 0.43, r = 0.46; p < 0.01). ♦ Conclusions A large proportion of PD patients whose treatment prescriptions are in accordance with the Dialysis Outcomes Quality Initiative guidelines were found to be overhydrated compared with a population of stable RTx patients. Fluid status was significantly related to DBP and eccentric LVH, whereas arterial distensibility of the common carotid artery was significantly related to SBP and concentric LVH. In contrast to ambulatory BP, office BP was not related to LVM.


Sign in / Sign up

Export Citation Format

Share Document