scholarly journals SP467DIALYSIS WITH REVERSED CONNECTED DOUBLE-LUMEN CATHETERS AND HIGH BLOOD FLOW RATES INCREASES RECIRCULATION BUT ENHANCES THE ADEQUACY OF DELIVERED HEMODIALYSIS

2019 ◽  
Vol 34 (Supplement_1) ◽  
Author(s):  
Varvara Kousoula ◽  
Panagiotis Georgianos ◽  
Konstantinos Mavromatidis ◽  
Christos Syrganis ◽  
Elias Thodis ◽  
...  
Keyword(s):  
1983 ◽  
Vol 6 (3) ◽  
pp. 127-130 ◽  
Author(s):  
C. Woffindin ◽  
N.A. Hoenich ◽  
D.N.S. Kerr

Data collected during the evaluation of a series of hemodialysers were analysed to see the effect of hematocrit on the clearance of urea and creatinine. All evaluations were performed on patients with a range of hematocrits with a mean close to 20%. The urea clearance of those in the upper half of the distribution curve (mean hematocrit 29.4%) was not significantly different from that of patients in the lower half of the distribution curve (mean hematocrit 16.9%) whether the clearance was studied at high or low blood flow rates and with hollow fibre or flat plate disposable hemodialysers. Likewise, there was no correlation between hematocrit and urea clearance by regression analysis. In contrast, the clearance of creatinine was affected by hematocrit being greater at lower hematocrit values. This difference was independent of blood flow rate and dialyser type and was confirmed by regression analysis.


1990 ◽  
Vol 68 (4) ◽  
pp. 1581-1589 ◽  
Author(s):  
T. Shibamoto ◽  
J. C. Parker ◽  
A. E. Taylor ◽  
M. I. Townsley

The capillary filtration coefficient (Kf,c) is a sensitive and specific index of vascular permeability if surface area remains constant, but derecruitment might affect Kf,c in severely damaged lungs with high vascular resistance. We studied the effect of high and low blood flow rates on Kf,c in papaverine-pretreated blood-perfused isolated dog lungs perfused under zone 3 conditions with and without paraquat (PQ, 10(-2) M). Three Kf,cs were measured successively at hourly intervals for 5 h. These progressed sequentially from isogravimetric blood flow with low vascular pressure (I/L) to high flow with low vascular pressure (H/L) to high flow with high vascular pressure (H/H). The blood flows of H/L and H/H were greater than or equal to 1.5 times that of I/L. There were no significant changes in Kf,c in lungs without paraquat over a 50-fold range of blood flow rates. At 3 h after PQ, I/L-Kf,c was significantly increased and both isogravimetric capillary pressure and total protein reflection coefficient were decreased from base line. At 4 and 5 h, H/L-Kf,c was significantly greater than the corresponding I/L-Kf,c (1.01 +/- 0.22 vs. 0.69 +/- 0.09 and 1.26 +/- 0.19 vs. 0.79 +/- 0.10 ml.min-1.cmH2O-1.100 g-1, respectively) and isogravimetric blood flow decreased to 32.0 and 12.0% of base line, respectively. Pulmonary vascular resistance increased to 12 times base line at 5 h after PQ. We conclude that Kf,c is independent of blood flow in uninjured lungs. However, Kf,c measured at isogravimetric blood flow underestimated the degree of increase in Kf,c in severely damaged and edematous lungs because of a high vascular resistance and derecruitment of filtering surface area.


2021 ◽  
Vol 12 ◽  
Author(s):  
M G Vossen ◽  
S Pferschy ◽  
C Milacek ◽  
M Haidinger ◽  
Mario Karolyi ◽  
...  

Background: Elimination of a drug during renal replacement therapy is not only dependent on flow rates, molecular size and protein binding, but is often influenced by difficult to predict drug membrane interactions. In vitro models allow for extensive profiling of drug clearance using a wide array of hemofilters and flow rates. We present a bovine blood based in vitro pharmacokinetic model for intermittent renal replacement therapy.Methods: Four different drugs were analyzed: gentamicin, doripenem, vancomicin and teicoplanin. The investigated drug was added to a bovine blood reservoir connected to a hemodialysis circuit. In total seven hemofilter models were analyzed using commonly employed flow rates. Pre-filter, post-filter and dialysate samples were drawn, plasmaseparated and analyzed using turbidimetric assays or HPLC. Protein binding of doripenem and vancomycin was measured in bovine plasma and compared to previously published values for human plasma.Results: Clearance values were heavily impacted by choice of membrane material and surface as well as by dialysis parameters such as blood flow rate. Gentamicin clearance ranged from a minimum of 90.12 ml/min in a Baxter CAHP-170 diacetate hemofilter up to a maximum of 187.90 ml/min in a Fresenius medical company Fx80 polysulfone model (blood flow rate 400 ml/min, dialysate flow rate 800 ml/min). Clearance of Gentamicin vs Vancomicin over the F80s hemofilter model using the same flow rates was 137.62 mL vs 103.25 ml/min. Doripenem clearance with the Fx80 was 141.25 ml/min.Conclusion: Clearance values corresponded very well to previously published data from clinical pharmacokinetic trials. In conjunction with in silico pharmacometric models. This model will allow precise dosing recommendations without the need of large scale clinical trials.


PEDIATRICS ◽  
1973 ◽  
Vol 52 (1) ◽  
pp. 95-99
Author(s):  
Ekkehard W. Reimold ◽  
Walter J. Reynolds ◽  
David E. Fixler ◽  
LaVerne McElroy

Hemodialysis was used in addition to forced diuresis in the treatment of quinidine poisoning of a 3-year-old girl. The estimated retained dose of quinidine was 1,600 mg. During a 36-hour treatment period the patient excreted through the kidneys 768.1 mg quinidine (21.3 mg/hr). Hemodialysis almost doubled the quinidine elimination by removing 145 mg in eight hours (18.1 mg/hr): renal excretion, 55%; hemodialysis, 45%. The quinidine elimination with dialysis is high when high blood flow rates through the artificial kidney can be maintained. Adequate glomerular filtration rate and urine acidification are necessary for high renal excretion of quinidine.


Author(s):  
Juliana H. Giffoni ◽  
Raffaella B. C. Teixeira ◽  
Raphael R. Wenceslau ◽  
Melina A. F. Abrantes ◽  
Jéssica G. Oliveira ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document