A MULTICENTRE SURVEY OF LOCAL DIAGNOSTIC REFERENCE LEVELS AND ACHIEVABLE DOSE FOR CORONARY ANGIOGRAPHY AND PERCUTANEOUS TRANSLUMINAL CORONARY INTERVENTION PROCEDURES IN KOREA

2019 ◽  
Vol 187 (3) ◽  
pp. 378-382
Author(s):  
Jung Su Kim ◽  
Bong-Ki Lee ◽  
Dong Ryeol Ryu ◽  
Kwang Jin Chun ◽  
Hyun-Hee Choi ◽  
...  

Abstract Interventional cardiology procedures can involve relatively high radiation doses compared to general radiography. During coronary angiography (CAG) and percutaneous transluminal coronary intervention (PCI), the same area is exposed to radiation for a long period. In this study, radiation exposure data of 1071 examinations in Korean hospitals were collected, and the achievable dose (AD) and diagnostic reference levels (DRLs) in actual medical practice for two types of interventional cardiology procedures in Korea were established. In CAG, 75th percentile DRLs and AD of the total kerma-area product were 47.0 and 33.1 Gy·cm 2, respectively. In PCI, those values were 171.3 and 102.6 Gy·cm2, respectively. This is the first study to introduce the DRLs for cardiovascular interventional procedures in Korea. These results will help optimise the interventional cardiology procedures for Korean cardiac centres.

2021 ◽  
Vol 31 (Supplement_2) ◽  
Author(s):  
Angela Cortez ◽  
Joana Santos ◽  
João Costa ◽  
Graciano Paulo

Abstract Background This study aims to assess the examination dose values in interventional cardiology procedures to establish diagnostic reference levels and analyse number of procedures that exceed trigger values. Methods Data about the procedure type, operator identification, procedure access, patient characteristics (gender, age and weight), fluoroscopy time (min), Kerma Area Product - PKA (Gy.cm2), was retrospectively collected, for a period of 12 months. Patients were categorised in three weight groups: low ( < 65 kg), standard (65–75kg) and high ( > 75 kg). Results he majority of the 2540 examinations were diagnostic procedures (65%) and the more common access was via the right radial artery (92%). Significant differences (P < 0.05) in fluoroscopy time and PKA values, between procedure access, patient weight group and type of procedure were found. The trigger level of PKA ( > 300Gy.cm2) value was exceeded in 0.5% of the procedures, lower than the incidence found in the literature. The local DRL values for diagnostic and therapeutical procedures were respectively 39 and 111 Gy.cm2, in line with values published in the literature. Conclusions The dose distribution is in line with the ones found in the literature. The percentage of patients that exceed one of trigger levels is lower when compared with the literature, however a patient follow-up plan should be established.


Hand ◽  
2021 ◽  
pp. 155894472199425
Author(s):  
Kiran R. Madhvani ◽  
Matthew J. R. Clark ◽  
Alex A. J. Kocheta

Background: Diagnostic reference levels are radiation dose levels in medical radiodiagnostic practices for typical examinations for groups of standard-sized individuals for broadly defined types of equipment. This study aimed to contribute to national diagnostic reference levels for common hand and wrist procedures using mini C-arm fluoroscopy. Small joint and digital fracture procedure diagnostic reference levels have not been reported in significant numbers previously with procedure-level stratification. Methods: Data were collected from fluoroscopy logbooks and were cross-referenced against the audit log kept on fluoroscopy machines. A total of 603 procedures were included. Results: The median radiation dose for wrist fracture open fixation was 2.73 cGycm2, Kirschner wiring (K-wiring) procedures was 2.36 cGycm2, small joint arthrodesis was 1.20 cGycm2, small joint injections was 0.58 cGycm2, and phalangeal fracture fixation was 1.05 cGycm2. Conclusions: Wrist fracture fixation used higher radiation doses than phalangeal fracture fixation, arthrodeses, and injections. Injections used significantly less radiation than the other procedures. There are significant differences in total radiation doses when comparing these procedures in hand and wrist surgery. National and international recommendations are that institutional audit data should be collected regularly and should be stratified by procedure type. This study helps to define standards for this activity by adding to the data available for wrist fracture diagnostic reference levels and defining standards for digital and injection procedures.


2013 ◽  
Vol 2013 ◽  
pp. 1-11 ◽  
Author(s):  
Zhonghua Sun ◽  
Aini AbAziz ◽  
Ahmad Khairuddin Md Yusof

Concerns about ionizing radiation during interventional cardiology have been increased in recent years as a result of rapid growth in interventional procedure volumes and the high radiation doses associated with some procedures. Noncancer radiation risks to cardiologists and medical staff in terms of radiation-induced cataracts and skin injuries for patients appear clear potential consequences of interventional cardiology procedures, while radiation-induced potential risk of developing cardiovascular effects remains less clear. This paper provides an overview of the evidence-based reviews of concerns about noncancer risks of radiation exposure in interventional cardiology. Strategies commonly undertaken to reduce radiation doses to both medical staff and patients during interventional cardiology procedures are discussed; optimisation of interventional cardiology procedures is highlighted.


2022 ◽  
Author(s):  
M. El Mansouri ◽  
M. Talbi ◽  
A. Choukri ◽  
O. Nhila ◽  
M. Aabid

In Morocco, the radiation doses received by adult patients are increasing due to the number of CT examinations performed and the larger number of computed tomography (CT) scanners installed. The aim of this study was to evaluate the radiation doses received by patients for the most common adult CT examinations in order to establish local diagnostic reference levels (DRLs). Data from 1016 adult patients were collected during 3 months from four Moroccan hospitals. Dose length product (DLP) and volumetric computed tomography dose index (CTDIvol) were evaluated by determining the 75th percentile as diagnostic reference levels for the most common examinations including head, chest and abdomen. The DRL for each examination was compared with other studies. The established DRLs in Morocco in terms of CTDIvol were 57.4, 12.3 and 10.9 for CT examinations of the head, chest, abdomen, respectively. For DLP, they were 1020, 632 and 714, respectively. These established DRLs for CTDIvol were almost similar to the UK DRLs at all examinations, higher than the Egyptian DRLs and lower than the Japanese DRLs at the head CT examination, lower than the DRLs from Egypt and Japan at the CT abdomen examination. In terms of DLP, the DRLs were higher than those of the British studies, lower than those of the Egyptian and Japanese studies at the head CT examination were higher at chest CT and lower at abdominal CT than those of all selected studies. The higher level of established DRLs in our study demonstrates the requirement of an optimization process while keeping a good image quality for a reliable diagnosis.


2021 ◽  
Author(s):  
Toru Ishibashi ◽  
Yasutaka Takei ◽  
Mamoru Kato ◽  
Yukari Yamashita ◽  
Atsuko Tsukamoto ◽  
...  

Abstract To propose Japanese national DRLs for air-kerma at the reference point (Ka,r), air-kerma area product (PKA), fluoroscopy time (FT), and number of cine images (CI) for four age groups. We posted a nationwide questionnaire to 132 facilities. Questions focused on identifying the procedure, age, weight, height, Ka,r, PKA, FT, and CI during diagnostic and therapeutic pediatric cardiac catheterization. For diagnostic cardiac angiography, the 75th percentile values were as follows; Ka,r: 103, 127, 194, and 351 mGy; PKA: 7.0, 12.3, 14.3, and 47.2 Gy.cm2; FT: 36.8, 30.7, 33.4, and 35.7 min; and CI: 2018, 2313, 2408, and 2016 images for less than one year, 1–5 years, 6–10 years, and 11–15 years respectively. For therapeutic cardiac angiography, the 75th percentile values were as follows: Ka,r: 146, 209, 130, and 501 mGy; PKA: 7.54, 16.0, 8.35, and 46.0 Gy.cm2; FT: 56.5, 52.0, 49.4, and 52.0 min; and CI: 4075, 4514, 3576, and 5984 images for less than one year, 1–5 years, 6–10 years, and 11–15 years respectively. Our survey of diagnostic and therapeutic cardiac catheterization in Japanese pediatric patients showed that all age-based Japanese 75th percentiles for the Ka,r, PKA, FT, and CI were higher than in other surveys. Based on the result of our study, it is necessary to establish DRLs for pediatric cardiac catheterization examinations in Japan, in order to optimize the safety of pediatric protocols for diagnostic and therapeutic cardiac catheterization.


2018 ◽  
Vol 184 (1) ◽  
pp. 1-4 ◽  
Author(s):  
A Brindhaban

Abstract The objective of this study was to evaluate dose–area product (DAP) and peak skin dose (PSD) for coronary angiography (CA) and percutaneous coronary intervention (PCI). The DAP and PSD of 300 randomly selected patients who were referred to CA and/or PCI, over a period of 3 months were recorded and analyzed. The mean DAP of 32 Gy cm2 and mean PSD of 412 mGy for CA were lower than 118 Gy cm2 and 857 mGy, respectively, for PCI. The DAP range of 2–84 Gy cm2 for CA and 12–378 mGy for PCI were also established. The maximum value of PSD for PCI procedures reached above the 2 Gy threshold for erythema. However, these values are similar to those available in literature. Periodic surveys may be required to monitor and/or reduce radiation doses in coronary interventional procedures.


2021 ◽  
Vol 17 (3) ◽  
pp. 216-221
Author(s):  
Fawad Yasin ◽  
Anum Rasheed ◽  
Muhammad Nauman Malik ◽  
Farheen Raza ◽  
Ramish Riaz ◽  
...  

OBJECTIVE - The purpose of this study was to assess the radiation dose levels from common computed tomography (CT) examinations performed in Radiology Department of Pakistan Institute of Medical Sciences (PIMS), and evaluate these according to diagnostic reference levels (DRLs) proposed by European Commission (EC) guidelines, and thus contributing towards the establishment of local and national DRLs. To the best of our knowledge, this is the first study of its kind to explore radiation doses from CT examinations in Pakistan. STUDY DESIGN - This was a quantitative study conducted at PIMS, Islamabad, spanning a duration of eight weeks. Scan parameters and dose profile data of 1506 adults undergoing examinations of head, neck, chest and abdomen-pelvis regions, comprising of single- and multi-phase, contrast-enhanced and unenhanced studies. Dose indicators utilized by EC guidelines for DRLs include volume CT dose index (CTDIvol) and Dose Length Product (DLP) for single slice and complete examination radiation doses, respectively. METHOD - Values of CTDIvol, DLP and scan lengths were extracted from the CT operators console. Other control variables included gender, contrast enhancement and phasicity of study. IBM SPSS package was used to obtain descriptive statistics such as mean and quartiles. RESULTS - DRLs calculated as 75th percentile of CTDIvol, DLP for various anatomical regions are by and far comparable to European DRLs. CONCLUSION – This study describes institutional diagnostic reference levels for common CT exams in Islamabad and provides benchmark values for future reference. Our DRL values are mostly comparable to European and international DRLs. Similar, albeit large scale, surveys are recommended for establishment of local and national DRLs, eventually contributing towards development of regional DRLs. KEYWORDS: CTDIvol, DLP, Diagnostic Reference Levels, Computed Tomography, Radiation Monitoring, Scan length


2021 ◽  
Vol 94 (1117) ◽  
pp. 20190878
Author(s):  
Anna Kropelnicki ◽  
Rosemary Eaton ◽  
Alexandra Adamczyk ◽  
Jacqueline Waterman ◽  
Pegah Mohaghegh

Objective: Mini C-arm fluoroscopes are widely used by orthopaedic surgeons for intraoperative image guidance without the need for radiographers. This puts the responsibility for radiation exposure firmly with the operating surgeon. In order to maintain safe and best practice under U.K. Ionising Radiation (Medical Exposure) Regulations, one must limit radiation exposure and audit performance using national diagnostic reference levels (DRLs). In the case of the mini C-arm, there are no national DRLs. IR(ME)R, therefore, require the establishment of local DRLs by each hospital to act as an alternative guideline for safe radiation use. The aim of our audit was to establish local DRLs based on our experience operating with the use of the mini C-arm over the last 7 years. Methods: This retrospective audit evaluates the end dose–area product (DAP) recorded for common trauma and orthopaedic procedures using the mini C-arm in a busy district general hospital. We present the quartile data and have set the cut-off point as the third quartile for formulating the local DRLs, consistent with the methodology for the conventional fluoroscope. Results: For our data set (n = 1664), the third quartile DAP values were lowest for surgeries to the forearm (5.38 cGycm2), hand (7.62 cGycm2), and foot/ankle (8.56 cGycm2), and highest for wrist (10.64 cGycm2) and elbow (14.61 cGycm2) procedures. Advances in knowledge: To our knowledge, this is the largest data set used to establish local DRLs. Other centres may find our guidelines useful whilst they establish their own local DRLs.


Sign in / Sign up

Export Citation Format

Share Document