Bedside Hemoglobinometry in Hemodialysis Patients: Lessons from Point-of-Care Testing

ASAIO Journal ◽  
2001 ◽  
Vol 47 (3) ◽  
pp. 240-243 ◽  
Author(s):  
Rajiv Agarwal ◽  
Tracy Heinz
2020 ◽  
Vol 2020 ◽  
pp. 1-6
Author(s):  
Céline B. Seghers ◽  
Kristien Ver Elst ◽  
Jolien Claessens ◽  
Steven Weekx ◽  
Sigrid Vermeiren ◽  
...  

Background. To measure International Normalized Ratio (INR) in hemodialysis patients with tunneled dialysis catheters (TDCs), blood sampling is frequently obtained via the catheter at the start of the session. INR measurements via finger-prick point of care testing (POCT) and via blood sampling taken from the dialysis circuit are evaluated as alternatives. Methods. In 14 hemodialysis patients with TDCs, treated with vitamin K antagonists (VKA), INR measurements via POCT were compared with plasma INR samples taken via the catheter at the start of dialysis and via the dialysis circuit after 30 and 60 minutes during 3 nonconsecutive dialysis sessions. Results. Blood samples taken at the start of dialysis at the catheter site were frequently contaminated with heparin originating from the locking solution (unfractionated heparin concentration (UFH) >1.0 IU/ml in 13.2%). POCT INR at the start of dialysis was not different from plasma INR after 30 and 60 minutes (Wilcoxon test p = 0.113 , n = 37, and p = 0.631 , n = 36, respectively). Moreover, there was no difference between POCT INR at the start of dialysis and POCT INR after 30 and 60 minutes (Wilcoxon test p = 0.797 and p = 0.801, respectively; n = 36). Passing and Bablok regression equation was used, y = 0.460 + 0.733x; n = 105. Treatment decisions based on these 2 methods showed a very good overall agreement (kappa = 0.810; 95% CI: 0.732–0.889; n = 105). Conclusions. Measuring plasma INR via the TDC at the start of dialysis should be abandoned. Measuring POCT INR via a finger prick at the start or even after 30 to 60 minutes is an alternative. The most elegant alternative is to take plasma INR samples via the dialysis circuit 30 minutes or later after the start of the dialysis.


2020 ◽  
Vol 27 ◽  
Author(s):  
Yi Zhang

: Point-of-care (POC) testing decentralizes the diagnostic tests to the sites near the patient. Many POC tests rely microfluidic platforms for sample-to-answer analysis. Compared to other microfluidic systems, magnetic digital microfluidics demonstrate compelling advantages for POC diagnostics. In this review, we have examined the capability of magnetic digital microfluidics-based POC diagnostic platforms. More importantly, we have categorized POC settings into three classes based on “where is the point”, “who to care” and “how to test”, and evaluated the suitability of magnetic digital microfluidics in various POC settings. Furthermore, we have addressed other technical issues associated with POC testing such as controlled environment, sample-system interface, system integration and information connectivity. We hope this review would provide a guideline for the future development of magnetic digital microfluidics-based platforms for POC testing.


The Analyst ◽  
2021 ◽  
Author(s):  
Tianshu Chu ◽  
Huili Wang ◽  
Yumeng Qiu ◽  
Haoxi Luo ◽  
Bingfang He ◽  
...  

Wearable sensors play a key role in point-of-care testing (POCT) for its flexible and integration capability on sensitive physiological and biochemical sensing. Here, we present a multifunction wearable silk patch...