scholarly journals Optical Quality and Visual Performance for One Year in a Sample of Scleral Lens Wearers. Optom Vis Sci 2020;97

2020 ◽  
Vol Publish Ahead of Print ◽  
2020 ◽  
Vol 97 (9) ◽  
pp. 775-789 ◽  
Author(s):  
Rute J. Macedo-de-Araújo ◽  
Miguel Faria-Ribeiro ◽  
Colm McAlinden ◽  
Eef van der Worp ◽  
José M. González-Méijome

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Xiao-ling Jiao ◽  
Jun Li ◽  
Zhe Yu ◽  
Ping-hui Wei ◽  
Hui Song

Abstract Background To compare visual performance between the iris-fixated phakic intraocular len (pIOL) and implantable collamer len (ICL) to correct high myopia. Methods Twenty-four eyes underwent iris-fixated pIOL implantation and 24 eyes underwent ICL implantation. At the 6-month follow-up, the best-corrected visual acuity (BCVA) and uncorrected distance visual acuity (UDVA) were compared between the iris-fixated pIOL and ICL groups. The objective scatter index (OSI), modulation transfer function (MTF) cutoff, and ocular aberrations were performed to evaluate postoperative visual quality between the two groups. Results No significant difference was found in UDVA, BCVA, and spherical equivalent between the iris-fixated pIOL and ICL groups (P > 0.05). Six months after surgery, the following values were significantly higher in the ICL group than in the iris-fixated pIOL group: MTF cutoff, strehl ratio and optical quality analysis system values at contrasts of 9 %, 20 %, and 100 % (P < 0.01). The OSI in the iris-fixated pIOL group was higher than in the ICL group 6 months after surgery (P < 0.01). All high-order aberrations were slightly more severe in the iris-fixated pIOL group than in the ICL group 6 months after surgery, although only trefoil (P = 0.023) differed significantly in this regard. Conclusions Both iris-fixated lenses and ICLs can provide good visual acuity. ICLs confer better visual performance in MTF-associated parameters and induce less intraocular light scattering than iris-fixated pIOLs.


2009 ◽  
Vol 92 (3) ◽  
pp. 289-296 ◽  
Author(s):  
Paul Schoneveld ◽  
Konrad Pesudovs ◽  
Douglas J Coster

2012 ◽  
Vol 32 (2) ◽  
pp. 100-116 ◽  
Author(s):  
Amit Jinabhai ◽  
Hema Radhakrishnan ◽  
Cindy Tromans ◽  
Clare O’Donnell

2014 ◽  
Vol 34 (5) ◽  
pp. 528-539 ◽  
Author(s):  
Amit Jinabhai ◽  
Clare O'Donnell ◽  
Cindy Tromans ◽  
Hema Radhakrishnan

2021 ◽  
Vol 15 ◽  
Author(s):  
Xue Li ◽  
Chenglu Ding ◽  
Yuhao Li ◽  
Ee Woon Lim ◽  
Yi Gao ◽  
...  

Purpose: This study aimed to evaluate short-term visual performance and optical quality of three different lenslet configurations on myopia control spectacle lenses.Materials and Methods: This study utilized a cross-over design. Distance visual acuity (VA) was measured in 50 myopic children; contrast sensitivity (CS) was measured in 36 myopic children. For each test, four spectacle lenses were evaluated in a random order: single-vision lens (SVL), lens with concentric rings of highly aspherical lenslets (HAL), lens with concentric rings of slightly aspherical lenslets (SAL), and lens with honeycomb configuration of spherical lenslets (HC). The modulation transfer function (MTF) and MTF area (MTFa) were used to determine optical quality. All tests were performed monocularly on the right eye with full correction.Results: HAL and SAL had larger MTFa than HC. VA in lenses with lenslets was significantly reduced compared to SVL (all p &lt; 0.01). The reduction in VA was worse with HC than with SAL (p = 0.02) and HAL (p = 0.03); no effect of lenslet asphericity was found (p &gt; 0.05). VA changes induced by lenslets showed no correlation with spherical equivalent refraction (all p &gt; 0.05) and were weakly positively associated with age for SAL (r = 0.36, p = 0.01) and HC (r = 0.31, p = 0.03), but not for HAL (p = 0.30). The area under the log contrast sensitivity function (AULCSF) decreased with HAL and HC (all p &lt; 0.001) in all illumination levels, and AULCSF with HAL was higher than that with HC in a photopic condition (1.17 ± 0.10 vs. 1.10 ± 0.13, p = 0.0004). The presence of lenslets did not affect CS at 3 cycles per degree (cpd) (p = 0.80). At 6 to 18 cpd, CS was significantly reduced by HAL and HC (all p &lt; 0.05), but not SAL (p &gt; 0.05) compared to SVL. At high spatial frequencies (&gt;12 cpd) both SAL and HAL reduced CS significantly less than HC (all p &lt; 0.01).Conclusion: Short-term visual performance was minimally impaired by looking through the lenslet structure of myopia control spectacle lenses. Concentric rings with aspherical lenslets had a significantly lower impact on both VA and CS than honeycomb configuration with spherical lenslets.


2017 ◽  
Vol 58 (7) ◽  
pp. 2899 ◽  
Author(s):  
Asaki Suzaki ◽  
Naoyuki Maeda ◽  
Mutsumi Fuchihata ◽  
Shizuka Koh ◽  
Kohji Nishida ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document