scholarly journals Engineering post-translational proofreading to discriminate non-standard amino acids

2017 ◽  
Author(s):  
Aditya M. Kunjapur ◽  
Devon A. Stork ◽  
Erkin Kuru ◽  
Oscar Vargas-Rodriguez ◽  
Matthieu Landon ◽  
...  

AbstractProgress in genetic code expansion requires accurate, selective, and high-throughput detection of non-standard amino acid (NSAA) incorporation into proteins. Here, we discover how the N-end rule pathway of protein degradation applies to commonly used NSAAs. We show that several NSAAs are N-end stabilizing and demonstrate that other NSAAs can be made stabilizing by rationally engineering the N-end rule adaptor protein ClpS. We use these insights to engineer a synthetic quality control method, termed “Post-Translational Proofreading” (PTP). By implementing PTP, false positive proteins resulting from misincorporation of structurally similar standard amino acids or undesired NSAAs rapidly degrade, enabling high-accuracy discrimination of desired NSAA incorporation. We illustrate the utility of PTP during evolution of the biphenylalanine orthogonal translation system used for synthetic biocontainment. Our new OTS is more selective and confers lower escape frequencies and greater fitness in all tested biocontained strains. Our approach presents a new paradigm for molecular recognition of amino acids in target proteins.

2020 ◽  
Vol 16 (7) ◽  
pp. 831-843
Author(s):  
Yuwen Wang ◽  
Shuping Li ◽  
Liuhong Zhang ◽  
Shenglan Qi ◽  
Huida Guan ◽  
...  

Background and Objective: Kang Fu Xin liquid (KFX) is an official preparation made from the ethanol extract product from P. Americana. The present quality control method cannot control the quality of the preparation well. The aim of the present study is to establish a convenient HPLC method for multicomponents determination combined with fingerprint analysis for quality control of KFX. Methods: An HPLC-DAD method with gradient elution and detective wavelength switching program was developed to establish HPLC fingerprints of KFX, and 38 batches of KFX were compared and evaluated by similarity analysis (SA), hierarchical clustering analysis (HCA), and principal component analysis (PCA). Meanwhile, six nucleosides and three amino acids, including uracil, hypoxanthine, uric acid, adenosine, xanthine, inosine, tyrosine, phenylalanine and tryptophan in KFX were determined based on the HPLC fingerprints. Results: An HPLC method assisted with gradient elution and wavelength switching program was established and validated for multicomponents determination combined with fingerprint analysis of KFX. The results demonstrated that the similarity values of the KFX samples were more than 0.845. PCA indicated that peaks 4 (hypoxanthine), 7 (xanthine), 9 (tyrosine), 11, 13 and 17 might be the characteristic contributed components. The nine constituents in KFX, uracil, hypoxanthine, uric acid, adenosine, xanthine, inosine, tyrosine, phenylalanine and tryptophan, showed good regression (R2 > 0.9997) within test ranges and the recoveries of the method for all analytes were in the range from 96.74 to 104.24%. The limits of detections and quantifications for nine constituents in DAD were less than 0.22 and 0.43 μg•mL-1, respectively. Conclusion: The qualitative analysis of chemical fingerprints and the quantitative analysis of multiple indicators provide a powerful and rational way to control the KFX quality for pharmaceutical companies.


Amino Acids ◽  
2020 ◽  
Author(s):  
Thomas L. Williams ◽  
Debra J. Iskandar ◽  
Alexander R. Nödling ◽  
Yurong Tan ◽  
Louis Y. P. Luk ◽  
...  

AbstractGenetic code expansion is a powerful technique for site-specific incorporation of an unnatural amino acid into a protein of interest. This technique relies on an orthogonal aminoacyl-tRNA synthetase/tRNA pair and has enabled incorporation of over 100 different unnatural amino acids into ribosomally synthesized proteins in cells. Pyrrolysyl-tRNA synthetase (PylRS) and its cognate tRNA from Methanosarcina species are arguably the most widely used orthogonal pair. Here, we investigated whether beneficial effect in unnatural amino acid incorporation caused by N-terminal mutations in PylRS of one species is transferable to PylRS of another species. It was shown that conserved mutations on the N-terminal domain of MmPylRS improved the unnatural amino acid incorporation efficiency up to five folds. As MbPylRS shares high sequence identity to MmPylRS, and the two homologs are often used interchangeably, we examined incorporation of five unnatural amino acids by four MbPylRS variants at two temperatures. Our results indicate that the beneficial N-terminal mutations in MmPylRS did not improve unnatural amino acid incorporation efficiency by MbPylRS. Knowledge from this work contributes to our understanding of PylRS homologs which are needed to improve the technique of genetic code expansion in the future.


Polymers ◽  
2021 ◽  
Vol 13 (3) ◽  
pp. 340
Author(s):  
Elisa Chiodi ◽  
Francesco Damin ◽  
Laura Sola ◽  
Lucia Ferraro ◽  
Dario Brambilla ◽  
...  

The manufacture of a very high-quality microarray support is essential for the adoption of this assay format in clinical routine. In fact, poorly surface-bound probes can affect the diagnostic sensitivity or, in worst cases, lead to false negative results. Here we report on a reliable and easy quality control method for the evaluation of spotted probe properties in a microarray test, based on the Interferometric Reflectance Imaging Sensor (IRIS) system, a high-resolution label free technique able to evaluate the variation of the mass bound to a surface. In particular, we demonstrated that the IRIS analysis of microarray chips immediately after probe immobilization can detect the absence of probes, which recognizably causes a lack of signal when performing a test, with clinical relevance, using fluorescence detection. Moreover, the use of the IRIS technique allowed also to determine the optimal concentration of the probe, that has to be immobilized on the surface, to maximize the target recognition, thus the signal, but to avoid crowding effects. Finally, through this preliminary quality inspection it is possible to highlight differences in the immobilization chemistries. In particular, we have compared NHS ester versus click chemistry reactions using two different surface coatings, demonstrating that, in the diagnostic case used as an example (colorectal cancer) a higher probe density does not reflect a higher binding signal, probably because of a crowding effect.


2014 ◽  
Vol 989-994 ◽  
pp. 3105-3109
Author(s):  
Xiao Bo Liu ◽  
Xiao Feng Wei ◽  
Xiao Dong Yuan ◽  
Wei Ni

This paper deals with the design and theoretical analysis on a novel vertical lift machine which can vertically lift above 700 kg load up to 3.2 meters above the floor and located the load with high accuracy of position and orientation. Firstly the design model based on the installment demands of line-replaceable units (LRUs) is constructed. Then theoretical analysis including the number of degree of freedom of the lift machine, the inverse kinematic, the control principle, the lift platform pose error and the precise pose control method are conducted in the article. The validity of the design model and the effectiveness of the precise pose control system are confirmed by experiments using a prototype lift machine.


2013 ◽  
Vol 141 (2) ◽  
pp. 798-808 ◽  
Author(s):  
Zhifang Xu ◽  
Yi Wang ◽  
Guangzhou Fan

Abstract The relatively smooth terrain embedded in the numerical model creates an elevation difference against the actual terrain, which in turn makes the quality control of 2-m temperature difficult when forecast or analysis fields are utilized in the process. In this paper, a two-stage quality control method is proposed to address the quality control of 2-m temperature, using biweight means and a progressive EOF analysis. The study is made to improve the quality control of the observed 2-m temperature collected by China and its neighboring areas, based on the 6-h T639 analysis from December 2009 to February 2010. Results show that the proposed two-stage quality control method can secure the needed quality control better, compared with a regular EOF quality control process. The new method is, in particular, able to remove the data that are dotted with consecutive errors but showing small fluctuations. Meanwhile, compared with the lapse rate of temperature method, the biweight mean method is able to remove the systematic bias generated by the model. It turns out that such methods make the distributions of observation increments (the difference between observation and background) more Gaussian-like, which ensures the data quality after the quality control.


Sign in / Sign up

Export Citation Format

Share Document