scholarly journals Success and failure of dead-time models as applied to hybrid pixel detectors in high-flux applications

2013 ◽  
Vol 20 (2) ◽  
pp. 347-354 ◽  
Author(s):  
B. A. Sobott ◽  
Ch. Broennimann ◽  
B. Schmitt ◽  
P. Trueb ◽  
M. Schneebeli ◽  
...  
Keyword(s):  
2020 ◽  
Vol 27 (2) ◽  
pp. 319-328 ◽  
Author(s):  
Leonardo Abbene ◽  
Fabio Principato ◽  
Gaetano Gerardi ◽  
Antonino Buttacavoli ◽  
Donato Cascio ◽  
...  

In this work, the spectroscopic performances of new cadmium–zinc–telluride (CZT) pixel detectors recently developed at IMEM-CNR of Parma (Italy) are presented. Sub-millimetre arrays with pixel pitch less than 500 µm, based on boron oxide encapsulated vertical Bridgman grown CZT crystals, were fabricated. Excellent room-temperature performance characterizes the detectors even at high-bias-voltage operation (9000 V cm−1), with energy resolutions (FWHM) of 4% (0.9 keV), 1.7% (1 keV) and 1.3% (1.6 keV) at 22.1, 59.5 and 122.1 keV, respectively. Charge-sharing investigations were performed with both uncollimated and collimated synchrotron X-ray beams with particular attention to the mitigation of the charge losses at the inter-pixel gap region. High-rate measurements demonstrated the absence of high-flux radiation-induced polarization phenomena up to 2 × 106 photons mm−2 s−1. These activities are in the framework of an international collaboration on the development of energy-resolved photon-counting systems for high-flux energy-resolved X-ray imaging.


2019 ◽  
Vol 67 (13) ◽  
pp. 3471-3486 ◽  
Author(s):  
Joshua Rapp ◽  
Yanting Ma ◽  
Robin M. A. Dawson ◽  
Vivek K Goyal

Author(s):  
Joshua Rapp ◽  
Yanting Ma ◽  
Robin M. A. Dawson ◽  
Vivek K Goyal

2018 ◽  
Author(s):  
Davide Braga ◽  
Luigi Gaioni ◽  
David Charles Christian ◽  
Grzegorz Deptuch ◽  
Farah Fahim ◽  
...  

2019 ◽  
Vol 26 (5) ◽  
pp. 1621-1630 ◽  
Author(s):  
Gabriel Blaj

Modern photon-counting pixel detectors have enabled a revolution in applications at synchrotron light sources and beyond in the last decade. One of the limitations of the current detectors is their reduced counting linearity or even paralysis at high counting rates, due to dead-time which results in photon pile-up. Existing dead-time and pile-up models fail to reproduce the complexity of dead-time effects on photon-counting, resulting in empirical calibrations for particular detectors at best, imprecise linearization methods, or no linearization. This problem will increase in the future as many synchrotron light sources plan significant brilliance upgrades and free-electron lasers plan moving to a quasi-continuous operation mode. Presented here are the first models that use the actual behavior of the analog pre-amplifiers in spectroscopic photon-counting pixel detectors with constant current discharge (e.g. the Medipix and CPix families of detectors) to deduce more accurate analytical models and optimal linearization methods. In particular, for detectors with at least two counters per pixel, the need for calibration, or previous knowledge of the detector and beam parameters (dead-time, integration time, large sets of synchrotron filling patterns), is completely eliminated. This is summarized in several models of increasing complexity and accuracy. Finally, a general empirical approach is presented, applicable to any particular cases where the analytical approach is not sufficiently precise.


2018 ◽  
Vol 25 (1) ◽  
pp. 257-271 ◽  
Author(s):  
Leonardo Abbene ◽  
Fabio Principato ◽  
Gaetano Gerardi ◽  
Manuele Bettelli ◽  
Paul Seller ◽  
...  

Cadmium–zinc–telluride (CZT) arrays with photon-counting and energy-resolving capabilities are widely proposed for next-generation X-ray imaging systems. This work presents the performance of a 2 mm-thick CZT pixel detector, with pixel pitches of 500 and 250 µm, dc coupled to a fast and low-noise ASIC (PIXIE ASIC), characterized only by the preamplifier stage. A custom 16-channel digital readout electronics was used, able to digitize and process continuously the signals from each output ASIC channel. The digital system performs on-line fast pulse shape and height analysis, with a low dead-time and reasonable energy resolution at both low and high fluxes. The spectroscopic response of the system to photon energies below (109Cd source) and above (241Am source) theK-shell absorption energy of the CZT material was investigated, with particular attention to the mitigation of charge sharing and pile-up. The detector allows high bias voltage operation (>5000 V cm−1) and good energy resolution at moderate cooling (3.5% and 5% FWHM at 59.5 keV for the 500 and 250 µm arrays, respectively) by using fast pulse shaping with a low dead-time (300 ns). Charge-sharing investigations were performed using a fine time coincidence analysis (TCA), with very short coincidence time windows up to 10 ns. For the 500 µm pitch array (250 µm pitch array), sharing percentages of 36% (52%) and 60% (82%) at 22.1 and 59.5 keV, respectively, were measured. The potential of the pulse shape analysis technique for charge-sharing detection for corner/border pixels and at high rate conditions (250 kcps pixel−1), where the TCA fails, is also shown. Measurements demonstrated that significant amounts of charge are lost for interactions occurring in the volume of the inter-pixel gap. This charge loss must be accounted for in the correction of shared events. These activities are within the framework of an international collaboration on the development of energy-resolved photon-counting systems for high-flux energy-resolved X-ray imaging (1–140 keV).


Author(s):  
JR Fryer ◽  
Z Huang ◽  
D Stirling ◽  
G. Webb

Platinum dispersed on γ-alumina is used as a reforming catalyst to convert linear hydrocarbons to cyclic aromatic products. To improve selectivity and lifetime of the catalyst, other elements are included, and we have studied the distributions of Pt/Re, and Pt/Sn, bimetallic systems on the support both before and after use in octane reforming. Often, one or both of the components are not resolvable by HREM or microanalysis as individual particles because of small size and lack of contrast on the alumina, and divergent beam microanalysis has been used to establish the presence and relationship between the two elements.In the majority of catalysts the platinum is in the form of small panicles, some of which are large enough to be resolvable in the microscope. The ABT002B microscope with Link windowless Pentafet detector, used in this work, was able to obtain a resolvable signal from particles of 2nm diameter upwards. When the beam was concentrated on to such a particle the signal was at a maximum, and as the beam diameter was diverged - at the same total beam intensity and dead time - the signal decreased as shown in Figure 1.


Sign in / Sign up

Export Citation Format

Share Document