scholarly journals Utilizing DNase I and graphene oxide modified magnetic nanoparticles for sensing PD-L1 in human plasma

Sensor Review ◽  
2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Xudong He ◽  
GuangYi Yang ◽  
E. Yang ◽  
Moli Zhang ◽  
Dan Luo ◽  
...  

Purpose Based on DNase I and reduced graphene oxide (rGO)-magnetic silicon microspheres (MNPS), a highly sensitive and selective fluorescent probe for the detection of PD-L1 was developed. Design/methodology/approach Here °C we present a feasibility of biosensor to detection of PD-L1 in lung tumors plasma. In the absence of PD-L1°C the PD-L1 aptamer is absorbed on the surface of graphene oxide modified magnetic nanoparticles °8rGO-MNPS°9 and leading to effective fluorescence quenching. Upon adding PD-L1°C the aptamer sequences could be specifically recognized by PD-L1 and the aptamer/PD-L1 complex is formed°C resulting in the recovery of quenched fluorescence. Findings This sensor can detect PD-L1 with a linear range from 100 pg mL−1 to 100 ng mL−1, and a detection limit of 10 pg•m−1 was achieved. Originality/value This method provides an easy and sensitive method for the detection of PD-L1 and will be beneficial to the early diagnosis and prognosis of tumors.

Sensor Review ◽  
2017 ◽  
Vol 37 (3) ◽  
pp. 312-321 ◽  
Author(s):  
Yixiang Bian ◽  
Can He ◽  
Kaixuan Sun ◽  
Longchao Dai ◽  
Hui Shen ◽  
...  

Purpose The purpose of this paper is to design and fabricate a three-dimensional (3D) bionic airflow sensing array made of two multi-electrode piezoelectric metal-core fibers (MPMFs), inspired by the structure of a cricket’s highly sensitive airflow receptor (consisting of two cerci). Design/methodology/approach A metal core was positioned at the center of an MPMF and surrounded by a hollow piezoceramic cylinder. Four thin metal films were spray-coated symmetrically on the surface of the fiber that could be used as two pairs of sensor electrodes. Findings In 3D space, four output signals of the two MPMFs arrays can form three “8”-shaped spheres. Similarly, the sensing signals for the same airflow are located on a spherical surface. Originality/value Two MPMF arrays are sufficient to detect the speed and direction of airflow in all three dimensions.


The Analyst ◽  
2018 ◽  
Vol 143 (1) ◽  
pp. 297-303 ◽  
Author(s):  
Yang Gao ◽  
Xiufeng Wu ◽  
Hui Wang ◽  
Wenbo Lu ◽  
Mandong Guo

The highly sensitive and selective electrochemical sensor of hesperidin based on gold nanoparticles (AuNPs) and reduced graphene oxide (rGO) modified glassy carbon electrode (GCE) is reported.


Sign in / Sign up

Export Citation Format

Share Document