Capacitance-type blade-tip clearance measurement system using a dual amplifier with ramp/DC inputs and integration

1992 ◽  
Vol 41 (5) ◽  
pp. 674-678 ◽  
Author(s):  
G.R. Sarma ◽  
J.P. Barranger
Author(s):  
A. G. Sheard ◽  
B. Killeen

It is difficult to make a reliable measurement of running clearance in the hostile environment over the blading of a modern gas turbine. When engine manufacturers require the measurement to be made over every blade during live engine tests, system reliability, ruggedness and ease of operation are of primary importance. This paper describes a tip clearance measurement system that can measure clearance over every blade around a rotor. The measurement system concept is presented, and the system design described in detail. Commissioning of the measurement system on a compressor test facility, and the results obtained are discussed. An analysis of system performance during the commissioning trials concludes the paper.


2011 ◽  
Vol 2011 ◽  
pp. 1-13 ◽  
Author(s):  
A. G. Sheard

This paper describes a capacitance-based tip clearance measurement system which engineers have used in the most demanding turbine test applications. The capacitance probe has survived extended use in a major European gas turbine manufacturer's high-temperature demonstrator unit, where it functioned reliably at a turbine entry temperature in excess of 1800 degrees Kelvin. This paper explores blade by blade tip clearance measurement techniques and examines probe performance under laboratory conditions in support of high-temperature installations. The paper outlines the blade by blade tip clearance measurement technique and describes the experimental facility used to study tip clearance measurement. The paper also fully describes the method used to calibrate the measurement system in order to ascertain measurement accuracy. The paper clarifies how the practical problems were overcome associated with making blade by blade tip clearance measurements in both compressor and turbine environments. Since its initial development, gas turbine development programmes have routinely used the clearance measurement system. The inherent robustness of the system has resulted in reliable in-service measurement of clearance in real world applications.


Author(s):  
Richard Grzybowski ◽  
George Foyt ◽  
Hartwig Knoell ◽  
William Atkinson ◽  
Josef Wenger

This paper describes the development of a Microwave Tip Clearance Measurement System for use in the gas turbine environment Applications for this sensor include basic tip clearance measurements, seal wear measurement and active blade tip clearance control in gas turbine engines. The system being developed was designed for useful operation to temperatures exceeding 1093°F, since only ceramic materials are directly exposed in the gas path. Other advantages of this microwave approach to blade tip clearance sensing include the existence of an inherent self-calibration in the sensor that permits accurate operation despite temperature variations and possible abrasion by the rotating blades. Earlier experiments designed to simulate this abrasion of the sensor head indicated that rubs as deep as 1 mm (40 mils) were easily tolerated. In addition, unlike methods based upon phase measurements, this method is very insensitive to cable vibration and length variations. Finally, this microwave technique is expected to be insensitive to fuel and other engine contamination, since it is based on the measurement of resonant frequencies, which are only slightly affected by moderate values of loss due to contamination.


2017 ◽  
Vol 2017 ◽  
pp. 1-9 ◽  
Author(s):  
Jia Binghui ◽  
He Lei

The benefits of reducing the tip clearance have been receiving many scholars’ attention all the time, which bring turbine efficiency increasing, emissions reduction, payloads increasing, and mission range abilities extension. In order to gain the blade tip clearance dynamically, a prototype optical fiber measurement system was built and tested based on the rotor test rig. The optical fiber tip clearance measurement system consists of the reflective intensity-modulated optical fiber bundle (sensor), main signal processing unit, high-speed data acquisition card, and a computer. The static performance and dynamic performance experiments were conducted to verify the performance of the system we designed. In addition, the results show that the accuracy of the system is 25 μm or better; the stability of the measurement system was evaluated in room temperature. The clearance measurement range is about 5 mm, and sensitivity of the sensor is 0.0733/mm. Furthermore, the typical tip clearance dynamic measurement experiment results show that the system has good dynamic response characteristics as well. The system will provide a new tool for engine health monitoring or fast active tip clearance control.


1981 ◽  
Vol 103 (2) ◽  
pp. 457-460 ◽  
Author(s):  
J. P. Barranger ◽  
M. J. Ford

The need for blade tip clearance instrumentation has been intensified recently by advances in technology of gas turbine engines. A new laser-optical measurement system has been developed to measure single blade tip clearances and average blade tip clearances between a rotor and its gas path seal in rotating component rigs and complete engines. The system is applicable to fan, compressor and turbine blade tipe clearance measurements. The engine mounted probe is particularly suitable for operation in the extreme turbine environment. The measurement system consists of an optical subsystem, an electronic subsystem and a computing and graphic terminal. Bench tests and environmental tests were conducted to confirm operation at temperatures, pressures, and vibration levels typically encountered in an operating gas turbine engine.


1995 ◽  
Vol 117 (2) ◽  
pp. 326-331 ◽  
Author(s):  
A. G. Sheard ◽  
B. Killeen

It is difficult to make a reliable measurement of running clearance in the hostile environment over the blading of a modern gas turbine. When engine manufacturers require the measurement to be made over every blade during live engine tests, system reliability, ruggedness, and ease of operation are of primary importance. This paper describes a tip clearance measurement system that can measure clearance over every blade around a rotor. The measurement system concept is presented, and the system design described in detail. Commissioning of the measurement system on a compressor test facility, and the results obtained are discussed. An analysis of system performance during the commissioning trials concludes the paper.


2018 ◽  
Vol 26 (7) ◽  
pp. 1578-1587 ◽  
Author(s):  
张小栋 ZHANG Xiao-dong ◽  
吴 冰 WU Bing ◽  
谢思莹 XIE Si-ying

Author(s):  
Harold R. Simmons ◽  
Douglas L. Michalsky ◽  
Kenneth E. Brewer ◽  
Anthony J. Smalley

This paper describes an optical measurement system for monitoring combustion turbine blade tips. The sensor measures distance to a blade tip using triangulation of reflected laser light. The system accomplishes triangulation using an optical position sensing device and high speed data acquisition. In this way, it is able to monitor not only average and minimum blade tip clearances, but to monitor the variations of individual blade tip clearances. By appropriate signal processing, it is possible to determine rotor vibration at the probe axial location, variations in shaft DC position, transient losses in blade tip clearance, the potential for tip and seal rubs, vibrations of individual blades in the tangential direction, and rotor torsional vibration at the probe location. Some aspects of blade and torsional vibrations would require more than one probe. The paper presents static calibration data for the measurement system, showing its degree of linearity and range. The paper also presents data obtained on a dynamic blade test rig with tip passing speeds and blade widths comparable to those encountered in high performance industrial combustion turbines. Data from this rig have been processed to show rotor vibration, shift in shaft average position, blade-to-blade tip clearance variation, and variation with speed of minimum blade tip clearance. The measurement system is designed to produce data suitable for use in the monitoring of advanced combustion turbine durability and the diagnosis of turbine functional problems, static and dynamic.


Materials ◽  
2019 ◽  
Vol 12 (21) ◽  
pp. 3552 ◽  
Author(s):  
Chun-Yi Zhang ◽  
Jing-Shan Wei ◽  
Ze Wang ◽  
Zhe-Shan Yuan ◽  
Cheng-Wei Fei ◽  
...  

To reveal the effect of high-temperature creep on the blade-tip radial running clearance of aeroengine high-pressure turbines, a distributed collaborative generalized regression extremum neural network is proposed by absorbing the heuristic thoughts of distributed collaborative response surface method and the generalized extremum neural network, in order to improve the reliability analysis of blade-tip clearance with creep behavior in terms of modeling precision and simulation efficiency. In this method, the generalized extremum neural network was used to handle the transients by simplifying the response process as one extremum and to address the strong nonlinearity by means of its nonlinear mapping ability. The distributed collaborative response surface method was applied to handle multi-object multi-discipline analysis, by decomposing one “big” model with hyperparameters and high nonlinearity into a series of “small” sub-models with few parameters and low nonlinearity. Based on the developed method, the blade-tip clearance reliability analysis of an aeroengine high-pressure turbine was performed subject to the creep behaviors of structural materials, by considering the randomness of influencing parameters such as gas temperature, rotational speed, material parameters, convective heat transfer coefficient, and so forth. It was found that the reliability degree of the clearance is 0.9909 when the allowable value is 2.2 mm, and the creep deformation of the clearance presents a normal distribution with a mean of 1.9829 mm and a standard deviation of 0.07539 mm. Based on a comparison of the methods, it is demonstrated that the proposed method requires a computing time of 1.201 s and has a computational accuracy of 99.929% over 104 simulations, which are improvements of 70.5% and 1.23%, respectively, relative to the distributed collaborative response surface method. Meanwhile, the high efficiency and high precision of the presented approach become more obvious with the increasing simulations. The efforts of this study provide a promising approach to improve the dynamic reliability analysis of complex structures.


Sign in / Sign up

Export Citation Format

Share Document