Estimation of ultrasonic guided wave mode conversion in a plate with thickness variation

2000 ◽  
Vol 47 (3) ◽  
pp. 591-603 ◽  
Author(s):  
Younho Cho
2005 ◽  
Vol 297-300 ◽  
pp. 2182-2186
Author(s):  
Ik Keun Park ◽  
Yong Kwon Kim ◽  
Youn Ho Cho ◽  
Won Joon Song ◽  
Yeon Shik Ahn ◽  
...  

A preliminary study of the behavior of ultrasonic guided wave mode in a pipe using a comb transducer for maintenance inspection of power plant facilities has been verified experimentally. Guided wave mode identification is carried out in a pipe using time-frequency analysis methods such as wavelet transform (WT) and short time Fourier transform (STFT), compared with theoretically calculated group velocity dispersion curves for longitudinal and flexural mode. The results are in good agreement with analytical predictions and show the effectiveness of using the time-frequency analysis method to identify the individual guided wave modes. And, It was found out that longitudinal mode (0, 1) is affected by mode conversion less than the other modes. Therefore, L (0, 1) is selected as a optimal mode for evaluating location of the surface defect in a pipe.


2013 ◽  
Vol 113 (14) ◽  
pp. 144904 ◽  
Author(s):  
Pasi Karppinen ◽  
Ari Salmi ◽  
Petro Moilanen ◽  
Timo Karppinen ◽  
Zuomin Zhao ◽  
...  

Sensors ◽  
2019 ◽  
Vol 19 (24) ◽  
pp. 5443 ◽  
Author(s):  
Anurag Dhutti ◽  
Saiful Asmin Tumin ◽  
Wamadeva Balachandran ◽  
Jamil Kanfoud ◽  
Tat-Hean Gan

High-temperature (HT) ultrasonic transducers are of increasing interest for structural health monitoring (SHM) of structures operating in harsh environments. This article focuses on the development of an HT piezoelectric wafer active sensor (HT-PWAS) for SHM of HT pipelines using ultrasonic guided waves. The PWAS was fabricated using Y-cut gallium phosphate (GaPO4) to produce a torsional guided wave mode on pipes operating at temperatures up to 600 °C. A number of confidence-building tests on the PWAS were carried out. HT electromechanical impedance (EMI) spectroscopy was performed to characterise piezoelectric properties at elevated temperatures and over long periods of time (>1000 h). Laser Doppler vibrometry (LDV) was used to verify the modes of vibration. A finite element model of GaPO4 PWAS was developed to model the electromechanical behaviour of the PWAS and the effect of increasing temperatures, and it was validated using EMI and LDV experimental data. This study demonstrates the application of GaPO4 for guided-wave SHM of pipelines and presents a model that can be used to evaluate different transducer designs for HT applications.


2006 ◽  
Vol 321-323 ◽  
pp. 795-798 ◽  
Author(s):  
Youn Ho Cho ◽  
Won Deok Oh ◽  
Joon Hyun Lee

This study presents a feasibility of using guided waves for a long-range inspection of pipe through investigation of mode conversion and scattering pattern from edge and wall-thinning in a steel pipe. Phase and group velocity dispersion curves for reference modes of pipes are illustrated for theoretical analyses. Predicted modes could be successfully generated by controlling frequency, receiver angle and wavelength. The dispersive characteristics of the modes from and edge wall-thinning are compared and analyzed respectively. The mode conversion characteristics are distinct depending on dispersive pattern of modes. Experimental feasibility study on the guided waves was carried out to explore wall thinning part in pipe for data calibration of a long range pipe monitoring by comb transducer and laser.


2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Maodan Yuan ◽  
Peter W. Tse ◽  
Weiming Xuan ◽  
Wenjin Xu

Ultrasonic guided wave (UGW) has shown great potential in the field of structural health monitoring of rail tracks due to its long-range capability and full cross section coverage. However, the practical application of UGW has been hindered by the complicated signal interpretation because of the natures of multiple modes and dispersion. Therefore, it is desirable that the effective UGW modes with high excitability and least dispersion can be identified and extracted for practical applications. In this paper, a numerical study on the guided wave propagation was carried out on a standard rail with 56E1 profile. Firstly, Floquet-Bloch theory was applied to obtain the dispersion curves of guided wave in a rail. Then, a 3D FE model was built to investigate the UGW propagation along the rail within the frequency range of 0–120 kHz. Wavenumber-frequency analysis method was applied to decompose and identify the propagating UGW modes. With a carefully designed 2D bandpass filter, a specific mode W0 was extracted in the wavenumber-frequency domain. Finally, a frequency band sweep technique was also proposed to get the optimal frequency band to achieve a pure and least-dispersive UGW mode along the rail web. The proposed method provides an effective way to extract efficient UGW modes to assess the integrity of the rail track, as well as other waveguides with complex geometry.


Author(s):  
Peng Zuo ◽  
Peter Huthwaite

Quantitative guided wave thickness mapping in plate-like structures and pipelines is of significant importance for the petrochemical industry to accurately estimate the minimum remaining wall thickness in the presence of corrosion, as guided waves can inspect a large area without needing direct access. Although a number of inverse algorithms have been studied and implemented in guided wave reconstruction, a primary assumption is widely used: the three-dimensional guided wave inversion of thickness is simplified as a two-dimensional acoustic wave inversion of velocity, with the dispersive nature of the waves linking thickness to velocity. This assumption considerably simplifies the inversion procedure; however, it makes it impossible to account for mode conversion. In reality, mode conversion is quite common in guided wave scattering with asymmetric wall loss, and compared with non-converted guided wave modes, converted modes may provide greater access to valuable information about the thickness variation, which, if exploited, could lead to improved performance. Geometrical full waveform inversion (GFWI) is an ideal tool for this, since it can account for mode conversion. In this paper, quantitative thickness reconstruction based on GFWI is developed in a plate cross-section and applied to study the performance of thickness reconstruction using mode conversion.


Author(s):  
Tomasz Wandowski ◽  
Pawel Malinowski ◽  
Pawel Kudela ◽  
Wieslaw Ostachowicz

Sign in / Sign up

Export Citation Format

Share Document