scholarly journals Systematic Proportional Method for Improving the Measurement Accuracy of Passive Sensor Measurement System

IEEE Access ◽  
2020 ◽  
Vol 8 ◽  
pp. 3980-3986
Author(s):  
Jintao Zhang ◽  
Gang Li ◽  
Yongshun Luo ◽  
Shuqiang Yang ◽  
Han Tian ◽  
...  
2021 ◽  
Vol 2021 ◽  
pp. 1-13
Author(s):  
Lei Xu ◽  
Ning Zhang ◽  
Liqing Fang ◽  
Huadong Chen ◽  
Pengfei Lin ◽  
...  

The magnetic gradient full-tensor measurement system is diverse, and the magnetometer array structure is complex. Aimed at the problem, seven magnetic gradient full-tensor measurement system models are studied in detail. The full-tensor measurement theories of the tensor measurement arrays are analyzed. Under the same baseline distance, the magnetic dipole model is used to simulate the measurement system. Based on different measurement systems, the paper quantitatively compares and analyzes the error of the structure. A more optimized magnetic gradient full-tensor measurement system is suggested. The simulation results show that the measurement accuracy of the planar measurement system is slightly higher than that of the stereo measurement system. Among them, the cross-shaped and square measurement systems have relatively smaller structural errors and higher measurement accuracy.


1990 ◽  
Vol 37 (10) ◽  
pp. 919-924 ◽  
Author(s):  
Y. Yamada ◽  
N. Yoshida ◽  
K. Kobayashi ◽  
K. Yamauchi

2011 ◽  
Vol 222 ◽  
pp. 62-65 ◽  
Author(s):  
Takeshi Hashimoto ◽  
Mitsuo Kaneko ◽  
András Rövid ◽  
Hiroaki Ohta ◽  
Akira Fukuda ◽  
...  

To reveal the influence of global warming on glaciers, highly accurate observations of glacier movement must continue every year. It is thought that there is a close relationship between glacier moving speed and global warming. Thus, there have been precise, detailed observations of the movement of the Perito Moreno glacier in Patagonia of the Argentine Republic over the past five years. The measurement method of using GPS and an optical measuring instrument is generally used to monitor glacier movement, but the measurement accuracy attained is not optimal because of the huge size of the glacier. The measurement system used for the Perito Moreno observations, however, could realize high accuracy measurement over long distance. The measurement system is based on the principle of stereo measurement using cameras. This paper describes the results of the Perito Moreno glacier observations of this year and considers the effectiveness of glacier observation using cameras.


2008 ◽  
Vol 392-394 ◽  
pp. 435-438
Author(s):  
Hua Guo ◽  
L. Bai ◽  
J. Liu ◽  
Y. Shi

This paper adopted the photoelectric micro measurement system based on CCD which was independently developed by Laboratory of Process Automatic and Detection Harbin Institute of Technology to detect dimension of the small precise parts. Under the various focusing status, it was discovered that articulation of focusing has huge effect on the measurement of measurand. According to the characteristics of measurand, we adopted the entropy function as the evaluation function of automatic focusing, developed a special software to process entropy value of the picked images, and obtained the relationship of focusing evaluation function and measurement error through a large number of experiments. The experimental result effectively verified the effect of articulation of focusing on dimension measurement.


2012 ◽  
Vol 47 ◽  
pp. 611-614 ◽  
Author(s):  
D. Mrugala ◽  
F. Ziegler ◽  
J. Kostelnik ◽  
W. Lang

2014 ◽  
Vol 687-691 ◽  
pp. 841-846 ◽  
Author(s):  
Rong Xiang Wang ◽  
Xia Zhang

In accordance with the principle of equal precision frequency measurement and theory of errors, in this paper, the problems are discussed that the equal precision frequency measurement eliminates the standard frequency count error. In order to reduce the relative error and improve the measurement accuracy, a method is proposed for phase coincide detection between standard frequency multiplication and measurement frequency demultiplication to open or shut the gate, at the same time, a signal selector is also used to improve circuit performance. This method can effectively solve the problem that the frequency can not be detected without the synchronization signal and improve the performance of the frequency measurement system.


Sign in / Sign up

Export Citation Format

Share Document