Performance of a Solar-Air Source Heat Pump System for Water Heating on Different Weather Conditions

Author(s):  
Guoying Xu ◽  
Xiaosong Zhang ◽  
Lei Yang ◽  
Shiming Deng
Author(s):  
Ahmad Riaz ◽  
Chao Zhou ◽  
Ruobing Liang ◽  
Jili Zhang

Photovoltaic thermal systems have gained tremendous popularity in the production of electric and thermal energy. In this paper, the photovoltaic thermal modules for the building façade assisted by heat pump system is proposed which combines the photovoltaic modules with an evaporator part of the heat pump system to produce hot water and electrical energy. Also, the photovoltaic thermal panels are used to preheat the cold ambient fresh air without heat pump operation. The proposed system was constructed at the Institute of Building Energy, Dalian University of Technology, China to study the ambient fresh air heating characteristic, electrical power generation, and hot water generation through performance evaluation indices under natural weather conditions. It was found that the average electrical, thermal, and overall efficiencies are 8.8%, 26%, and 50%, respectively during the pre-heating of fresh air. While the average air temperature is 15.2°C inside an air gap. The average COP for water heating is 3.91 during the water heating mode. This study could be used as a guide for photovoltaic thermal solar-assisted heat pump systems on building envelopes in a multi-energy generation under different weather conditions. Practical application: The study considers the photovoltaic thermal modules for building façade not only to generate the electrical energy and pre-heated fresh air but also to generate the hot water when assisted with the heat pump system. This research could assist researchers and engineers in the field of photovoltaic thermal façade systems in multi-energy generation such as for the production of electricity, heated/cooled fresh air, and hot water generation.


Author(s):  
Zhang Guihong ◽  
Yang Yi ◽  
Chen Jianbo ◽  
Mei Tianxiang ◽  
Gu Haiqin ◽  
...  

2022 ◽  
Vol 182 ◽  
pp. 86-101
Author(s):  
Haidan Wang ◽  
Yulong Song ◽  
Yiyou Qiao ◽  
Shengbo Li ◽  
Feng Cao

2021 ◽  
Vol 9 ◽  
Author(s):  
Jie Jia ◽  
Xuan Zhou ◽  
Wei Feng ◽  
Yuanda Cheng ◽  
Qi Tian ◽  
...  

The simultaneous need for energy efficiency and indoor comfort may not be met by existing air source heat pump (ASHP) technology. The novelty of this study lies in the use of a new gravity-driven radiator as the indoor heating terminal of ASHPs, aiming to provide an acceptable indoor comfort with improved energy efficiency. To confirm and quantify the performance improvement due to the proposed system retrofit, a field test was conducted to examine the system performance under real conditions. In the tests, measurements were made on the refrigerant- and air-side of the system to characterize its operational characteristics. Results showed that the proposed radiator has a rapid thermal response, which ensures a fast heat output from the system. The proposed system can create a stable and uniform indoor environment with a measured air diffusion performance index of 80%. The energy efficiency of the proposed system was also assessed based on the test data. It was found that the system’s first law efficiency is 42.5% higher than the hydraulic-based ASHP system. In terms of the second law efficiency, the compressor contributes the most to the overall system exergy loss. The exergy efficiency of the proposed system increases with the outdoor temperature and varies between 35.02 and 38.93% in the test period. The research results and the analysis methodology reported in this study will be useful for promoting the technology in search of energy efficiency improvement in residential and commercial buildings.


2013 ◽  
Vol 13 (9) ◽  
pp. 1406-1414
Author(s):  
Wang He ◽  
Liu Yong-Shun ◽  
Liu Xiao-Li ◽  
Duan Jin-Hui ◽  
Xue Song ◽  
...  

Author(s):  
Z Yuhan ◽  
W Jinshun ◽  
L Mu ◽  
Z Xingxing ◽  
Z Lining ◽  
...  