A Game Model based Distributed Power Dispatch for Wind Generators in Wind Farm with Variable Communication

Author(s):  
Jianliang Zhang ◽  
Donglian Qi
2013 ◽  
Vol 33 (9) ◽  
pp. 2525-2528
Author(s):  
Rui WANG ◽  
Qiuxiang YANG ◽  
Gouxi CHEN ◽  
Qiaomei MA

2013 ◽  
Vol 756-759 ◽  
pp. 4171-4174 ◽  
Author(s):  
Xiao Ming Wang ◽  
Xing Xing Mu

With the Asynchronous wind generators as research object, this paper analyzes the problems of the voltage stability and the generation mechanism of the reactive power compensation during the wind farms connected operation. For paralleling capacitor bank has shown obvious defects, therefore this paper employs dynamic reactive power compensation to improve reactive characteristics of grid-connected wind farms. With the influences of different wind disturbances and grid faults on wind farms, wind farm model is set up and dynamic reactive power compensation system and wind speeds are built in the Matlab/Simulink software, The simulation result shows that they can provide reactive power compensation to ensure the voltage stability of the wind farms. But STATCOM needs less reactive compensation capacity to make sure the voltage and active power approaching steady state before the faults more quickly, Therefore STATCOM is more suitable for wind farms connected dynamic reactive power compensation.


2012 ◽  
Vol 260-261 ◽  
pp. 257-262
Author(s):  
Feng Ting Li ◽  
Chang Sheng Su

In allusion to the problems of convention current protection when it was used to collect circuit of wind farm, the relay protection should consider the short-circuit current of wind generators; The principle of adaptive current protection was described, the fault current and attenuation characteristic of asynchronous wind generator was studied, the scheme of adaptive current protection was proposed for wind farm operation. Taking PSCAD/EMTDC as the platform, simulation and record the voltage and current sample-data of different wind farm operation which can guarantee high sensitivity phase selection, the high accuracy wind generators impedance measure method based on FFT filter DC component is presented , and using MATLAB program achieved the scheme of adaptive current protection. Simulation results demonstrate that collect circuit adaptive current protection is adaptive wind farm operation model, and enhance the operation benefit of wind farm.


2017 ◽  
Vol 8 (2) ◽  
pp. 638-647 ◽  
Author(s):  
Peng Hou ◽  
Weihao Hu ◽  
Mohsen Soltani ◽  
Cong Chen ◽  
Baohua Zhang ◽  
...  

Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4291
Author(s):  
Paxis Marques João Roque ◽  
Shyama Pada Chowdhury ◽  
Zhongjie Huan

District of Namaacha in Maputo Province of Mozambique presents a high wind potential, with an average wind speed of around 7.5 m/s and huge open fields that are favourable to the installation of wind farms. However, in order to make better use of the wind potential, it is necessary to evaluate the operating conditions of the turbines and guide the independent power producers (IPPs) on how to efficiently use wind power. The investigation of the wind farm operating conditions is justified by the fact that the implementation of wind power systems is quite expensive, and therefore, it is imperative to find alternatives to reduce power losses and improve energy production. Taking into account the power needs in Mozambique, this project applied hybrid optimisation of multiple energy resources (HOMER) to size the capacity of the wind farm and the number of turbines that guarantee an adequate supply of power. Moreover, considering the topographic conditions of the site and the operational parameters of the turbines, the system advisor model (SAM) was applied to evaluate the performance of the Vestas V82-1.65 horizontal axis turbines and the system’s power output as a result of the wake effect. For any wind farm, it is evident that wind turbines’ wake effects significantly reduce the performance of wind farms. The paper seeks to design and examine the proper layout for practical placements of wind generators. Firstly, a survey on the Namaacha’s electricity demand was carried out in order to obtain the district’s daily load profile required to size the wind farm’s capacity. Secondly, with the previous knowledge that the operation of wind farms is affected by wake losses, different wake effect models applied by SAM were examined and the Eddy–Viscosity model was selected to perform the analysis. Three distinct layouts result from SAM optimisation, and the best one is recommended for wind turbines installation for maximising wind to energy generation. Although it is understood that the wake effect occurs on any wind farm, it is observed that wake losses can be minimised through the proper design of the wind generators’ placement layout. Therefore, any wind farm project should, from its layout, examine the optimal wind farm arrangement, which will depend on the wind speed, wind direction, turbine hub height, and other topographical characteristics of the area. In that context, considering the topographic and climate features of Mozambique, the study brings novelty in the way wind farms should be placed in the district and wake losses minimised. The study is based on a real assumption that the project can be implemented in the district, and thus, considering the wind farm’s capacity, the district’s energy needs could be met. The optimal transversal and longitudinal distances between turbines recommended are 8Do and 10Do, respectively, arranged according to layout 1, with wake losses of about 1.7%, land utilisation of about 6.46 Km2, and power output estimated at 71.844 GWh per year.


2019 ◽  
Vol 74 ◽  
pp. 451-465 ◽  
Author(s):  
Hong-gang Peng ◽  
Xiao-kang Wang ◽  
Tie-li Wang ◽  
Jian-qiang Wang

2019 ◽  
Vol 180 ◽  
pp. 391-400 ◽  
Author(s):  
Luis Ignacio Levieux ◽  
Fernando A. Inthamoussou ◽  
Hernán De Battista

Sign in / Sign up

Export Citation Format

Share Document