Adaptive threshold QRS detection algorithm for ambulatory ECG

Author(s):  
K. Akazawa ◽  
K. Motoda ◽  
A. Sasamori ◽  
T. Ishizawa ◽  
E. Harasawa
2015 ◽  
Vol 8 (11) ◽  
pp. 4671-4679 ◽  
Author(s):  
J. Yang ◽  
Q. Min ◽  
W. Lu ◽  
W. Yao ◽  
Y. Ma ◽  
...  

Abstract. Obtaining an accurate cloud-cover state is a challenging task. In the past, traditional two-dimensional red-to-blue band methods have been widely used for cloud detection in total-sky images. By analyzing the imaging principle of cameras, the green channel has been selected to replace the 2-D red-to-blue band for detecting cloud pixels from partly cloudy total-sky images in this study. The brightness distribution in a total-sky image is usually nonuniform, because of forward scattering and Mie scattering of aerosols, which results in increased detection errors in the circumsolar and near-horizon regions. This paper proposes an automatic cloud detection algorithm, "green channel background subtraction adaptive threshold" (GBSAT), which incorporates channel selection, background simulation, computation of solar mask and cloud mask, subtraction, an adaptive threshold, and binarization. Five experimental cases show that the GBSAT algorithm produces more accurate retrieval results for all these test total-sky images.


2016 ◽  
Vol 78 (7-5) ◽  
Author(s):  
Muhammad Amin Hashim ◽  
Yuan Wen Hau ◽  
Rabia Baktheri

This paper studies two different Electrocardiography (ECG) preprocessing algorithms, namely Pan and Tompkins (PT) and Derivative Based (DB) algorithm, which is crucial of QRS complex detection in cardiovascular disease detection. Both algorithms are compared in terms of QRS detection accuracy and computation timing performance, with implementation on System-on-Chip (SoC) based embedded system that prototype on Altera DE2-115 Field Programmable Gate Array (FPGA) platform as embedded software. Both algorithms are tested with 30 minutes ECG data from each of 48 different patient records obtain from MIT-BIH arrhythmia database. Results show that PT algorithm achieve 98.15% accuracy with 56.33 seconds computation while DB algorithm achieve 96.74% with only 22.14 seconds processing time. Based on the study, an optimized PT algorithm with improvement on Moving Windows Integrator (MWI) has been proposed to accelerate its computation. Result shows that the proposed optimized Moving Windows Integrator algorithm achieves 9.5 times speed up than original MWI while retaining its QRS detection accuracy. 


2011 ◽  
Vol 204-210 ◽  
pp. 1386-1389
Author(s):  
Deng Yin Zhang ◽  
Li Xiao ◽  
Shun Rong Bo

The existing edge detection algorithms with wavelet transform need to artificially set the threshold value and are lack of flexibility.To salve the limitations, in this paper, we propose a WT(wavelet transform)-based edge detection algorithm with adaptive threshold, which uses threshold value iteration method to achieve adaptive threshold setting. Comparison of experiment results for the CT image shows that the method which improve the clarity and continuity of the image edge can effectively distinguish edge and noise, and get more completely information of the edge. It has good application value in the fields of medical clinical diagnosis and image processing.


2019 ◽  
Vol 9 (10) ◽  
pp. 2142 ◽  
Author(s):  
Chun-Cheng Lin ◽  
Hung-Yu Chang ◽  
Yan-Hua Huang ◽  
Cheng-Yu Yeh

Accurate QRS detection is an important first step for almost all automatic electrocardiogram (ECG) analyzing systems. However, QRS detection is difficult, not only because of the wide variety of ECG waveforms but also because of the interferences caused by various types of noise. This study proposes an improved QRS complex detection algorithm based on a four-level biorthogonal spline wavelet transform. A noise evaluation method is proposed to quantify the noise amount and to select a lower-noise wavelet detail signal instead of removing high-frequency components in the preprocessing stage. The QRS peaks can be detected by the extremum pairs in the selected wavelet detail signal and the proposed decision rules. The results show the high accuracy of the proposed algorithm, which achieves a 0.25% detection error rate, 99.84% sensitivity, and 99.92% positive prediction value, evaluated using the MIT-BIT arrhythmia database. The proposed algorithm improves the accuracy of QRS detection in comparison with several wavelet-based and non-wavelet-based approaches.


Sensors ◽  
2020 ◽  
Vol 20 (14) ◽  
pp. 4003 ◽  
Author(s):  
Aiyun Chen ◽  
Yidan Zhang ◽  
Mengxin Zhang ◽  
Wenhan Liu ◽  
Sheng Chang ◽  
...  

As one of the important components of electrocardiogram (ECG) signals, QRS signal represents the basic characteristics of ECG signals. The detection of QRS waves is also an essential step for ECG signal analysis. In order to further meet the clinical needs for the accuracy and real-time detection of QRS waves, a simple, fast, reliable, and hardware-friendly algorithm for real-time QRS detection is proposed. The exponential transform (ET) and proportional-derivative (PD) control-based adaptive threshold are designed to detect QRS-complex. The proposed ET can effectively narrow the magnitude difference of QRS peaks, and the PD control-based method can adaptively adjust the current threshold for QRS detection according to thresholds of previous two windows and predefined minimal threshold. The ECG signals from MIT-BIH databases are used to evaluate the performance of the proposed algorithm. The overall sensitivity, positive predictivity, and accuracy for QRS detection are 99.90%, 99.92%, and 99.82%, respectively. It is also implemented on Altera Cyclone V 5CSEMA5F31C6 Field Programmable Gate Array (FPGA). The time consumed for a 30-min ECG record is approximately 1.3 s. It indicates that the proposed algorithm can be used for wearable heart rate monitoring and automatic ECG analysis.