Comparison of Voltage Divider In-phase and Quadrature Error Measurement Between NMIA and NIM

Author(s):  
Xianlin Pan ◽  
Ilya Budovsky ◽  
Zhaomin Shi ◽  
Jiangtao Zhang
Author(s):  
A. V. Crewe ◽  
M. W. Retsky

A 100 kv scanning transmission microscope has been built. Briefly, the design is as follows: The electron gun consists of a field emission point and a 3 cm Butler gun. The beam has a crossover outside the gun and is collimated by a condenser lens.The parallel beam passes through a defining aperture and is focused by the objective lens onto the specimen. The elastic electrons are detected by two annular detectors, each subtending a different angle, and the unscattered and inelastic electrons are collected by a third detector. The spectrometer that will separate the inelastic and unscattered electrons has not yet been built.The lens current supplies are stable to within one part per million per hour and have been described elsewhere.The high voltage is also stable to 1 ppm/hr. It consists of the raw supply from a 100 kv Spellman power supply controlled by an external reference voltage, high voltage divider, and error amplifier.


2017 ◽  
Vol 34 (5) ◽  
pp. 532
Author(s):  
Li Gu ◽  
Xiang Li ◽  
Fangke Zong ◽  
Junlan Zhou ◽  
Qinlao Yang ◽  
...  
Keyword(s):  

Sensors ◽  
2021 ◽  
Vol 21 (11) ◽  
pp. 3668
Author(s):  
Chi-Chun Chen ◽  
Shu-Yu Lin ◽  
Wen-Ying Chang

This study presents a noncontact electrocardiogram (ECG) measurement system to replace conventional ECG electrode pads during ECG measurement. The proposed noncontact electrode design comprises a surface guard ring, the optimal input resistance, a ground guard ring, and an optimal voltage divider feedback. The surface and ground guard rings are used to reduce environmental noise. The optimal input resistor mitigates distortion caused by the input bias current, and the optimal voltage divider feedback increases the gain. Simulated gain analysis was subsequently performed to determine the most suitable parameters for the design, and the system was combined with a capacitive driven right leg circuit to reduce common-mode interference. The present study simulated actual environments in which interference is present in capacitive ECG signal measurement. Both in the case of environmental interference and motion artifact interference, relative to capacitive ECG electrodes, the proposed electrodes measured ECG signals with greater stability. In terms of R–R intervals, the measured ECG signals exhibited a 98.6% similarity to ECGs measured using contact ECG systems. The proposed noncontact ECG measurement system based on capacitive sensing is applicable for use in everyday life.


Sign in / Sign up

Export Citation Format

Share Document