guard ring
Recently Published Documents


TOTAL DOCUMENTS

313
(FIVE YEARS 41)

H-INDEX

22
(FIVE YEARS 3)

Crystals ◽  
2021 ◽  
Vol 11 (10) ◽  
pp. 1186
Author(s):  
Hong Zhou ◽  
Shifan Zeng ◽  
Jincheng Zhang ◽  
Zhihong Liu ◽  
Qian Feng ◽  
...  

In this paper, we carried out a comprehensive study and optimization of implementing p-NiO in the β-Ga2O3 based diodes, including Schottky barrier diode (SBD) with p-NiO guard ring (GR), p-NiO/β-Ga2O3 heterojunction (HJ) barrier Schottky (HJBS) diode, and HJ-PN diode through the TCAD simulation. In particular, we provide design guidelines for future p-NiO-related Ga2O3 diodes with material doping concentrations and dimensions to be taken into account. Although HJ-PN has a ~1 V higher turn-on voltage (Von), its breakdown voltage (BV) is the highest among all diodes. We found that for SBD with p-NiO GRs and HJBS, their forward electrical characteristics and reverse leakage current are related to the total width and the doping concentration of p-NiO, the BV is only related to the doping concentration of p-NiO, and the optimal doping concentration of p-NiO is found to be 4 × 1017 cm−3. Compared with the SBD without p-NiO, the BV of the SBD with p-NiO and HJBS diode can be essentially improved by 3 times. As a result, HJ-PN diode, SBD with p-NiO GRs, and HJ-BS diode achieve a BV/specific on-resistance (Ron,sp) of 5705 V/4.3 mΩ·cm2, 3006 V/3.07 mΩ·cm2, and 3004 V/3.06 mΩ·cm2, respectively. Based on different application requirements, this work provides a useful insight about the diode selection with various structures.


2021 ◽  
Vol 60 (06) ◽  
Author(s):  
Seyed Saman Kohneh Poushi ◽  
Hiwa Mahmoudi ◽  
Michael Hofbauer ◽  
Bernhard Steindl ◽  
Kerstin Schneider-Hornstein ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4270
Author(s):  
Lars Daul ◽  
Tao Jin ◽  
Ingo Busch ◽  
Ludger Koenders

Capacitive sensors are widely used in industrial applications, such as CNC machine tools, where reliable positioning in the micrometer range with nanometer accuracy is required. Hence, these sensors are operated in harsh industrial environments. The accuracy of these sensors is mainly limited by slope errors and nonlinearities. In practice, the required accuracy of these sensors is achieved by a calibration against a metrological high-quality reference such as interferometric displacement measurement systems. This usually involves the use of high-order polynomials as calibration functions based on empirical data. In metrology, this is only the second-best approach and has disadvantages in terms of stability over the measurement range of the instrument. In addition, the validity of these empirical calibrations over time is questionable, and the associated uncertainty can only be roughly estimated. This makes regular recalibration of such sensors at short intervals mandatory to ensure the reliability of the displacement measurement. In this paper, we report on our investigations of the different parameters that affect the accuracy of capacitive sensors. Since the capacitance of these sensors results from the electric fields that build up between the electrodes, these field lines are calculated using FEM simulation models for typical commercial sensors. In the following the influence of various geometric parameters such as edge radius, guard ring size and shape, or thickness of the electrodes are individually analyzed according to their impact on the accuracy of these sensors. Based on these simulations, the deviations of the capacitance as they arise for real detector geometries can then be compared with idealized, de facto unrealizable parallel plate capacitors. This methodology allows overall uncertainty of capacitive sensors to be decomposed into their individual components and sorted in terms of their contribution to the uncertainty budget. The individual FEM-based analysis then enables a systematic analysis of the sources of uncertainty and, thus, reveals possibilities to improve manufacturing processes for capacitive sensors, to put these sensors on a solid metrological basis, and to improve the performance of these displacement measurement systems in the long run, i.e., to provide better sensors for the application.


Sensors ◽  
2021 ◽  
Vol 21 (11) ◽  
pp. 3668
Author(s):  
Chi-Chun Chen ◽  
Shu-Yu Lin ◽  
Wen-Ying Chang

This study presents a noncontact electrocardiogram (ECG) measurement system to replace conventional ECG electrode pads during ECG measurement. The proposed noncontact electrode design comprises a surface guard ring, the optimal input resistance, a ground guard ring, and an optimal voltage divider feedback. The surface and ground guard rings are used to reduce environmental noise. The optimal input resistor mitigates distortion caused by the input bias current, and the optimal voltage divider feedback increases the gain. Simulated gain analysis was subsequently performed to determine the most suitable parameters for the design, and the system was combined with a capacitive driven right leg circuit to reduce common-mode interference. The present study simulated actual environments in which interference is present in capacitive ECG signal measurement. Both in the case of environmental interference and motion artifact interference, relative to capacitive ECG electrodes, the proposed electrodes measured ECG signals with greater stability. In terms of R–R intervals, the measured ECG signals exhibited a 98.6% similarity to ECGs measured using contact ECG systems. The proposed noncontact ECG measurement system based on capacitive sensing is applicable for use in everyday life.


2021 ◽  
Vol 151 ◽  
pp. 106820
Author(s):  
Jiyu Zhou ◽  
Liang He ◽  
Xiaobo Li ◽  
Taofei Pu ◽  
Liuan Li ◽  
...  

2021 ◽  
Vol 16 (02) ◽  
pp. P02034-P02034
Author(s):  
S. Oussalah ◽  
M. Mekheldi ◽  
W. Filali ◽  
E. Garoudja

Author(s):  
NITHI ATTHI ◽  
Witsaroot Sripumkhai ◽  
Pattaraluck Pattamang ◽  
Oraphan Thongsook ◽  
Rattanawan Meananeatra ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document