Increasing CCD frame rate and signal-to-noise ratio with high resolution capability using on-chip preprocessing and multisignal image representation

Author(s):  
Fedor Inochkin ◽  
Sergey Kruglov ◽  
Igor Bronshtein
2014 ◽  
Vol 74 (6) ◽  
pp. 1587-1597 ◽  
Author(s):  
Mitchell A. Cooper ◽  
Thanh D. Nguyen ◽  
Bo Xu ◽  
Martin R. Prince ◽  
Michael Elad ◽  
...  

2008 ◽  
Vol 55 (3) ◽  
pp. 842-852 ◽  
Author(s):  
M.C. Maas ◽  
D.R. Schaart ◽  
D.J. van der Laan ◽  
H.T. van Dam ◽  
J. Huizenga ◽  
...  

Sensors ◽  
2018 ◽  
Vol 18 (8) ◽  
pp. 2598
Author(s):  
Min Kim ◽  
Jinhyoung Park ◽  
Qifa Zhou ◽  
Koping Shung

In this article, an approach to designing and developing an ultrahigh frequency (≤600 MHz) ultrasound analog frontend with Golay coded excitation sequence for high resolution imaging applications is presented. For the purpose of visualizing specific structures or measuring functional responses of micron-sized biological samples, a higher frequency ultrasound is needed to obtain a decent spatial resolution while it lowers the signal-to-noise ratio, the difference in decibels between the signal level and the background noise level, due to the higher attenuation coefficient. In order to enhance the signal-to-noise ratio, conventional approach was to increase the transmit voltage level. However, it may cause damaging the extremely thin piezoelectric material in the ultrahigh frequency range. In this paper, we present a novel design of ultrahigh frequency (≤600 MHz) frontend system capable of performing pseudo Golay coded excitation by configuring four independently operating pulse generators in parallel and the consecutive delayed transmission from each channel. Compared with the conventional monocycle pulse approach, the signal-to-noise ratio of the proposed approach was improved by 7–9 dB without compromising the spatial resolution. The measured axial and lateral resolutions of wire targets were 16.4 µm and 10.6 µm by using 156 MHz 4 bit pseudo Golay coded excitation, respectively and 4.5 µm and 7.7 µm by using 312 MHz 4 bit pseudo Golay coded excitation, respectively.


Author(s):  
S. Sanjith ◽  
R. Ganesan

Measuring the quality of image is very complex and hard process since the opinion of the humans are affected by physical and psychological parameters. So many techniques are invented and proposed for image quality analysis but none of the methods suits best for it. Assessment of image quality plays an important role in image processing. In this paper we present the experimental results by comparing the quality of different satellite images (ALOS, RapidEye, SPOT4, SPOT5, SPOT6, SPOTMap) after compression using four different compression methods namely Joint Photographic Expert Group (JPEG), Embedded Zero tree Wavelet (EZW), Set Partitioning in Hierarchical Tree (SPIHT), Joint Photographic Expert Group – 2000 (JPEG 2000). The Mean Square Error (MSE), Signal to Noise Ratio (SNR) and Peak Signal to Noise Ratio (PSNR) values are calculated to determine the quality of the high resolution satellite images after compression.


Sign in / Sign up

Export Citation Format

Share Document