Binary Pattern Color Doppler Shear Wave Elastography*

Author(s):  
Norma Hermawan ◽  
Aoi Sato ◽  
Mizuki Fujiwara ◽  
Takuro Ishii ◽  
Yoshihiro Hagiwara ◽  
...  
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Xue Zheng ◽  
Fei Li ◽  
Zhi-Dong Xuan ◽  
Yu Wang ◽  
Lei Zhang

Abstract Background To explore the value of quantitative shear wave elastography (SWE) plus the Breast Imaging Reporting and Data System (BI-RADS) in the identification of solid breast masses. Methods A total of 108 patients with 120 solid breast masses admitted to our hospital from January 2019 to January 2020 were enrolled in this study. The pathological examination served as the gold standard for definitive diagnosis. Both SWE and BI-RADS grading were performed. Results Out of the 120 solid breast masses in 108 patients, 75 benign and 45 malignant masses were pathologically confirmed. The size, shape, margin, internal echo, microcalcification, lateral acoustic shadow, and posterior acoustic enhancement of benign and malignant masses were significantly different (all P < 0.05). The E mean, E max, SD, and E ratio of benign and malignant masses were significantly different (all P < 0.05). The E min was similar between benign and malignant masses (P > 0.05). The percentage of Adler grade II-III of the benign masses was lower than that of the malignant masses (P < 0.05). BI-RADS plus SWE yielded higher diagnostic specificity and positive predictive value than either BI-RADS or SWE; BI-RADS plus SWE yielded the highest diagnostic accuracy among the three methods (all P < 0.05). Conclusion SWE plus routine ultrasonography BI-RADS has a higher value in differentiating benign from malignant breast masses than color doppler or SWE alone, which should be further promoted in clinical practice.


2017 ◽  
Vol 43 ◽  
pp. S90
Author(s):  
Yoshiki Yamakoshi ◽  
Takahito Nakajima ◽  
Mayuko Yamazaki ◽  
Kana Taniuchi ◽  
Yoshino Ishimori ◽  
...  

Author(s):  
Yoshiki Yamakoshi ◽  
Takahito Nakajima ◽  
Toshihiro Kasahara ◽  
Mayuko Yamazaki ◽  
Ren Koda ◽  
...  

2021 ◽  
Vol 10 (11) ◽  
pp. 2351
Author(s):  
Daniel Baur ◽  
Christoph Schwabl ◽  
Christian Kremser ◽  
Mihra S. Taljanovic ◽  
Gerlig Widmann ◽  
...  

Background: The purpose of this study was to evaluate plantar fasciae of healthy subjects and patients with plantar fasciitis by shear wave velocity (SWV) and stiffness with correlation to B-Mode and color Doppler ultrasonography (CDUS) and to establish cut-off values. Methods: This observational study was conducted with the approval of the Institutional Review Boards (IRBs) of our institution. 108 unilateral plantar fasciae were evaluated by including 87 consecutive patients (mean age 51.7; range: 29–82) (66 women and 21 men) with plantar fasciitis and 21 asymptomatic age matched healthy volunteers (mean age 47.3; range: 32–58) (15 women and 6 men). All patients were prospectively imaged between July 2018 and March 2019. B-mode US was used to measure thickness and CDUS to grade vascularity. SWE measurements were repeated 3 times and mean was used for statistical analysis. Results: Mean SWV value in healthy subjects was 6.94 m/s and in patients 4.98 m/s with a mean stiffness value of 152.88 kPa and 93.54 kPa respectively (p < 0.001). For SWV a cut-off value of 6.16 m/s had a specificity of 80.95% and sensitivity of 79.31%. For stiffness a cut-off value of 125.57 kPa had a specificity of 80.95% and sensitivity of 80.46%. No correlation to CDUS was found. The mean thickness of healthy fascias was 3.3 mm (range 2.4–3.9) compared to 6.1 mm (range 2.0–22.0) in plantar fasciitis (p < 0.001) with no correlation to SWV or to stiffness (r² = 0.02, p = 0.06). Conclusion: SWE allows quantitative assessment of plantar fascia stiffness, which decreases in patients with plantar fasciitis. No correlation to the thickness of the plantar fascia was found, therefore it represents an independent factor for the diagnosis of plantar fasciitis and could be helpful in addition to thickness measurement in unclear cases.


Author(s):  
Ahmed Abd Alrahman Baz ◽  
Afaf Hamdy Ibrahim Mohamed ◽  
Yasmine Fathy Ghazi El-Esawy ◽  
Khaled Helmy El-kaffas

Abstract Background Although a minority of the thyroid nodules is malignant, usually the invasive diagnostic procedures are warranted. This prospective study aims to assess the diagnostic performance of the US criteria in addition to the TI-RADS score and the SWE for the differentiation between the benign and malignant thyroid nodules as a potential surrogate for the invasive procedures. Results Ninety-nine patients with thyroid nodules (79 females and 20 males, with a mean age of 45.9 ± 7.7 years; 30–69 years) were enrolled in this study and underwent conventional ultrasound, color Doppler, TI-RADS scoring, and shear wave elastography (SWE); the findings were correlated to the histopathological results. Our results revealed a significant increase in SWE elasticity indices (EIs) and presence of color Doppler signals in malignant nodules as compared with the benign ones (ρ < 0.05). Combined TI-RADS and SWE as well as TI-RADS and color Doppler imaging had given a better sensitivity for detection of malignancy. Conclusion Elasticity indices had shown a significantly high diagnostic performance that is almost approaching the histopathological results. Combined SWE, color Doppler and TI-RADS, as a sum of findings, could effectively differentiate between benign and malignant thyroid nodules. Furthermore, it had offered a non-invasive tool for accurate risk stratification of malignant nodules.


Author(s):  
Divina D’Auria ◽  
Ludovica Fulgione ◽  
Valeria Romeo ◽  
Arnaldo Stanzione ◽  
Simone Maurea ◽  
...  

AbstractIn this pictorial essay, we illustrate the ultrasound appearance of COVID-19 Pfizer-BioNTech vaccine-related lymph node abnormalities, which can occur at different stations ipsilateral to the site of vaccination, after either first or second vaccine dose and can represent a diagnostic dilemma when encountered in patients with underlying conditions. Typically, they appear as enlarged hypoechoic nodes with loss of fat hilum, increased hilar and cortical vascularization at color-Doppler, but low to intermediate cortical consistence at shear-wave elastography. Asymmetric or diffuse cortical thickening is also frequently encountered. They can be observed in patients without and with clinical symptoms, such as armpit pain, fever and fatigue.


Author(s):  
Vito Cantisani ◽  
Emanuele David ◽  
Richard G. Barr ◽  
Maija Radzina ◽  
Valeria de Soccio ◽  
...  

Abstract Purpose To evaluate the diagnostic performance of strain elastography (SE) and 2 D shear wave elastography (SWE) and SE/SWE combination in comparison with conventional multiparametric ultrasound (US) with respect to improving BI-RADS classification results and differentiating benign and malignant breast lesions using a qualitative and quantitative assessment. Materials and Methods In this prospective study, 130 histologically proven breast masses were evaluated with baseline US, color Doppler ultrasound (CDUS), SE and SWE (Toshiba Aplio 500 with a 7–15 MHz wide-band linear transducer). Each lesion was classified according to the BIRADS lexicon by evaluating the size, the B-mode and color Doppler features, the SE qualitative (point color scale) and SE semi-quantitative (strain ratio) methods, and quantitative SWE. Histological results were compared with BIRADS, strain ratio (SR) and shear wave elastography (SWE) all performed by one investigator blinded to the clinical examination and mammographic results at the time of the US examination. The area under the ROC curve (AUC) was calculated to evaluate the diagnostic performance of B-mode US, SE, SWE, and their combination. Results Histological examination revealed 47 benign and 83 malignant breast lesions. The accuracy of SR was statistically significantly higher than SWE (sensitivity, specificity and AUC were 89.2 %, 76.6 % and 0.83 for SR and 72.3 %, 66.0 % and 0.69 for SWE, respectively, p = 0.003) but not higher than B-mode US (B-mode US sensitivity, specificity and AUC were 85.5 %, 78.8 %, 0.821, respectively, p = 1.000). Conclusion Our experience suggests that conventional US in combination with both SE and SWE is a valid tool that can be useful in the clinical setting, can improve BIRADS category assessment and may help in the differentiation of benign from malignant breast lesions, with SE having higher accuracy than SWE.


2016 ◽  
Vol 26 (10) ◽  
pp. 3542-3549 ◽  
Author(s):  
Ji Soo Choi ◽  
Boo-Kyung Han ◽  
Eun Young Ko ◽  
Eun Sook Ko ◽  
Jung Hee Shin ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document