Chance-constrained reactive power planning of wind farm integrated distribution system considering voltage stability

Author(s):  
Wang Man ◽  
Qiu Chendong
2013 ◽  
Vol 756-759 ◽  
pp. 4171-4174 ◽  
Author(s):  
Xiao Ming Wang ◽  
Xing Xing Mu

With the Asynchronous wind generators as research object, this paper analyzes the problems of the voltage stability and the generation mechanism of the reactive power compensation during the wind farms connected operation. For paralleling capacitor bank has shown obvious defects, therefore this paper employs dynamic reactive power compensation to improve reactive characteristics of grid-connected wind farms. With the influences of different wind disturbances and grid faults on wind farms, wind farm model is set up and dynamic reactive power compensation system and wind speeds are built in the Matlab/Simulink software, The simulation result shows that they can provide reactive power compensation to ensure the voltage stability of the wind farms. But STATCOM needs less reactive compensation capacity to make sure the voltage and active power approaching steady state before the faults more quickly, Therefore STATCOM is more suitable for wind farms connected dynamic reactive power compensation.


Author(s):  
Mahesh Kumar ◽  
Perumal Nallagownden ◽  
Irraivan Elamvazuthi ◽  
Pandian Vasant ◽  
Luqman Hakim Rahman

In the distribution system, distributed generation (DG) are getting more important because of the electricity demands, fossil fuel depletion and environment concerns. The placement and sizing of DGs have greatly impact on the voltage stability and losses in the distribution network. In this chapter, a particle swarm optimization (PSO) algorithm has been proposed for optimal placement and sizing of DG to improve voltage stability index in the radial distribution system. The two i.e. active power and combination of active and reactive power types of DGs are proposed to realize the effect of DG integration. A specific analysis has been applied on IEEE 33 bus system radial distribution networks using MATLAB 2015a software.


2020 ◽  
Vol 64 (2) ◽  
pp. 157-169
Author(s):  
Benalia M'hamdi ◽  
Madjid Teguar ◽  
Benaissa Tahar

The optimal allocation and size of decentralized generating units are essential to minimize power losses, while meeting the demand for active and reactive power in a distribution system. In other words, most of the total energy produced can be efficiently exploited by end users. In addition, if the DGs are of optimal size and location in the distribution system, the reliability, stability and efficiency of the power system are guaranteed. This paper focuses on reducing power losses and improving the voltage profile by accurately identifying the optimal location and sizing of Distributed Generation based on three indexes, namely the IVM Index Vector Method, the VDI Voltage Deviation Index and the VSI Voltage Stability Index. Two types of DGs were considered for the analysis: DGs operating with unit power factor and DGs operating with a lagging power factor. Three optimization algorithms are applied to determine the optimal sizes of decentralized generation units in a power distribution network which are GWO, WOA and PSO. The results obtained in this article show that the three algorithms give very similar values. DG at lagging power factor gives better results compared with those obtained with DGs at unity power factor. In terms of loss reduction and minimum bus voltage, the best results are obtained for the VSI index with a DG at a power factor of 0.9.


2013 ◽  
Vol 694-697 ◽  
pp. 846-849
Author(s):  
Jian Yuan Xu ◽  
Wei Fu Qi ◽  
Yun Teng

This paper mainly studies wind power fluctuations how to affect voltage stability after the wind power grid integration, and reactive power compensation equipment on improving effect. In certain parts of the wind farm, for example, firstly, analyzing the wind farm reactive power problems. Then introduce the reactive power compensation equipment that used in the wind farm. Finally, with PSCAD software, making a simulation analysis about the influence on the power grid voltage according to adopting the different reactive power compensation devices or not.


2014 ◽  
Vol 1070-1072 ◽  
pp. 224-227
Author(s):  
Li Lin ◽  
Kai Li

Current control strategy of reactive power and voltage for wind power integration is separate control of single wind farm (WF), which cannot achieve the optimal allocation of reactive power and is not beneficial for the optimization of voltage stability and network loss. In this paper, a coordinated control strategy of reactive power and voltage for wind farm cluster is proposed, which takes the voltage stability at point of common coupling (PCC) and economic operation as the optimization goals. The coordinated control strategy is realized through the platform of Cybercontrol industrial configuration, and the application testing verifies the effectiveness of the proposed strategy.


2017 ◽  
Vol 26 (4) ◽  
pp. 81
Author(s):  
Manju Aggarwal ◽  
Madhusudan Singh ◽  
S.K. Gupta

In a low voltage distribution system with integrated wind plant, voltage stability is impacted by the large variation of load and wind penetration. The compensators like SVC and DSTATCOM are currently being used to address such issue of voltage instability. This paper analyses the impact of wind penetration and variation of active and reactive power of the load on voltage profile of a wind generation system with and without DSTATCOM. It also analyses the performance of the system during fault by calculating various parameters of the system. It has been demonstrated that voltage stability margin increases using DSTATCOM at different wind penetration levels. This system has been simulated and analysed in MATLAB 2011b using a power system toolbox under steady state and transient conditions.


2019 ◽  
Vol 9 (4) ◽  
pp. 4384-4388 ◽  
Author(s):  
D. N. Truong ◽  
V. T. Bui

The objective of this paper is to perform a hybrid design for an Adaptive Neuro-Fuzzy Inference System (ANFIS) optimized by Particle Swarm Optimization (PSO) to improve the dynamic voltage stability of a grid-connected wind power system. An onshore 99.2MW wind farm using Doubly Fed Induction Generator (DFIG) is studied. To compensate the reactive power absorbed from the power grid of the wind farm, a Static VAR Compensator (SVC) is proposed. To demonstrate the performance of the proposed hybrid PSO–ANFIS controller, simulations of the voltage response in time-domain are performed in Matlab to evaluate the effectiveness of the designed controller. From the results, it can be concluded that the proposed hybrid PSO-optimized ANFIS-based model can be applied to enhance the dynamic voltage stability of the studied grid-connected wind power system.


Sign in / Sign up

Export Citation Format

Share Document