Study of Control Strategy about Central Air-Conditioning Control System

Author(s):  
Xianmei Zhao ◽  
Hongying Su ◽  
Xi Liu
2014 ◽  
Vol 525 ◽  
pp. 621-624
Author(s):  
Xue Jing Sun

In this paper, based on the Siemens S7-200 programmable controller in the central air conditioning control system, hardware and software of the central air-conditioning control system is designed. In hardware design PLC controller is used as controlling core to control temperature and humidity of the entire process. In the software design, control programming and multi-loop control of temperature, humidity PID algorithm are completed by using PLC programming software STEP7 because of its characteristics that it is easy to read and easy to achieve complete control. Lastly, Related parameter is set and the information is displayed by touching screen.


2014 ◽  
Vol 602-605 ◽  
pp. 1472-1475
Author(s):  
Li Ming Wei ◽  
Chen Li

In this paper, hardware and software of the central air-conditioning control system is researched by STC series of enhanced 8051 microcontroller. The STC11F 08XE is the main control of the hardware part. Temperature and humidity sensor regulating valve and all kinds of motor are used as external equipment to complete the temperature and humidity of building the internal control of central air conditioner. In terms of software, the program is described by protel99SE software. Microcontroller program is compiled by Microcontroller development tools keil u and STC-ISP. The temperature and humidity control and optimization of central air conditioning are completed by PID parameters. Infrared control unit is operated and liquid crystal is displayed to show the operation results.


2014 ◽  
Vol 602-605 ◽  
pp. 1468-1471
Author(s):  
Xue Jing Sun

In this paper, microcontroller is applied in the central air conditioning control system. Firstly, microcontroller controller is used as controlling core to control temperature and humidity of central air conditioning control system. Secondly, PID algorithm parameters are set up for improving traditional PID control principle. Lastly, input and output values can be set and displayed by LCD screen.


2014 ◽  
Vol 960-961 ◽  
pp. 639-642
Author(s):  
Xue Jing Sun

In this paper, microcontroller is applied in the central air conditioning control system. Firstly, microcontroller controller is used as controlling core to control temperature and humidity of central air conditioning control system. Secondly, PID algorithm parameters are set up for improving traditional PID control principle. Lastly, input and output values can be set and displayed by LCD screen.


2014 ◽  
Vol 1039 ◽  
pp. 328-333 ◽  
Author(s):  
Tao Han ◽  
Xue Feng Lai ◽  
Liang Wen Yan ◽  
Zai Feng Zhang

Abstract. With the SIEMENS S7-200 PLC and HMI based on KingView being the master, a slave station of STM32F103C8T6 microcontroller is developed based on MODBUS protocol. The establishment and program designing of communication protocol using RS485/RS232 between master and slave is introduced firstly. Then the process of debugging between the microcontroller and PC, the microcontroller and the PLC is elaborated. Thus serial communication is implemented based on MODBUS protocol in RTU mode. The system will be applied in central air-conditioning control system. A good control effect will be obtained as the controlling strategy and main algorithm can be computed in the STM32 slave station.


2014 ◽  
Vol 960-961 ◽  
pp. 658-661
Author(s):  
Li Ming Wei ◽  
Chen Li

In this paper, hardware and software of the central air-conditioning control system is researched by STC series of enhanced 8051 microcontroller. The STC11F 08XE is the main control of the hardware part. Temperature and humidity sensor regulating valve and all kinds of motor are used as external equipment to complete the temperature and humidity of building the internal control of central air conditioner. In terms of software, the program is described by protel99SE software. Microcontroller program is compiled by Microcontroller development tools keil u and STC-ISP. The temperature and humidity control and optimization of central air conditioning are completed by PID parameters. Infrared control unit is operated and liquid crystal is displayed to show the operation results.


2013 ◽  
Vol 774-776 ◽  
pp. 407-410
Author(s):  
Qiu Hua Miao ◽  
Zhi Guang Guan

In this paper, a kind of efficient air-conditioning control system is proposed. PIC18F458 is adopted as main control unit of the system , which collects all kinds of analog singles such as temperature, humidity and so on, then convert them to digital by the A/D itself. After disposing and calculating each analog signal the system drives corresponding actuator to work to adjust temperature, humidity and cleanness of the air in bus, making passengers satisfied with air quality in bus.