scholarly journals Wind Farm to Weak-Grid Connection using UPQC custom power device

Author(s):  
M. F. Farias ◽  
P. E. Battaiotto ◽  
M. G. Cendoya
Author(s):  
Kopella Sai Teja ◽  
R.B.R. Prakash

<p>Wind farm is connected to the grid directly.The wind is not constant voltage fluctuations occur at point of common coupling (PCC) and WF terminal . To over come this problem a new compensation strategy is used . By using Custom power devices (UPQC).It injects reactive power at PCC . The advantages of UPQC is it consists of both DVR and D-STATCOM . DVR is connected in series to the line and it injects in phase voltage into the line .D-STATCOM is connected shunt to the line .The internal control strategy is based on management of active and reactive power in series and shunt converters of UPQC . The power exchainge is done by using DC-link</p>


2016 ◽  
Vol 4 (2) ◽  
pp. 256-264 ◽  
Author(s):  
Xinshou TIAN ◽  
Gengyin LI ◽  
Yongning CHI ◽  
Weisheng WANG ◽  
Haiyan TANG ◽  
...  

Author(s):  
Innocent Onyebuchi Ozioko ◽  
Nnaemeka Sunday Ugwuanyi ◽  
Arthur Obiora Ekwue

Energies ◽  
2020 ◽  
Vol 13 (13) ◽  
pp. 3316 ◽  
Author(s):  
Dong Wang ◽  
Xiaojie Zhang ◽  
Lei Yang ◽  
Yunhui Huang ◽  
Wei Huang ◽  
...  

Recent studies show that the loss of stability for a voltage-source converter (VSC) in weak-grid connection is largely related to its synchronization unit, i.e., the phase-locked loop (PLL). This paper studies the synchronization stability of a system comprised by two VSCs in parallel connection to a weak grid. A reduced transfer function based small-signal model, which can allow for the interactions between PLL and converter outer power controls, is first proposed. Then, an improved net damping criterion is used to analyze the damping and stability characters of such system under various operating conditions and different controller configurations. Compared to the conventional net damping criterion, the used criterion has wider applicability in terms of stability judgment. Case studies show that the studied system tends to be unstable at weak-grid or heavy-loading conditions. The instability can be in the form of oscillations or monotonic divergence, in which, the latter is more likely to occur for the converters without grid voltage regulation capabilities. Besides, the net damping-based sensitivity studies can provide guidance on control tuning or design for stability enhancement. Detailed model-based time domain simulations are conducted to verify the analysis results.


2015 ◽  
Vol 2015 ◽  
pp. 1-11 ◽  
Author(s):  
Lihui Guo ◽  
Hao Bai

With the increasing penetration of wind power, the randomness and volatility of wind power output would have a greater impact on safety and steady operation of power system. In allusion to the uncertainty of wind speed and load demand, this paper applied box set robust optimization theory in determining the maximum allowable installed capacity of wind farm, while constraints of node voltage and line capacity are considered. Optimized duality theory is used to simplify the model and convert uncertainty quantities in constraints into certainty quantities. Under the condition of multi wind farms, a bilevel optimization model to calculate penetration capacity is proposed. The result of IEEE 30-bus system shows that the robust optimization model proposed in the paper is correct and effective and indicates that the fluctuation range of wind speed and load and the importance degree of grid connection point of wind farm and load point have impact on the allowable capacity of wind farm.


Sign in / Sign up

Export Citation Format

Share Document