Research and Analysis on the Specialty of Relay Protection and Automation Technology in Power System

Author(s):  
Liu Ruihua
Author(s):  
B. Venkateswara Rao ◽  
Ramesh Devarapalli ◽  
H. Malik ◽  
Sravana Kumar Bali ◽  
Fausto Pedro García Márquez ◽  
...  

The trend of increasing demand creates a gap between generation and load in the field of electrical power systems. This is one of the significant problems for the science, where it require to add new generating units or use of novel automation technology for the better utilization of the existing generating units. The automation technology highly recommends the use of speedy and effective algorithms in optimal parameter adjustment for the system components. So newly developed nature inspired Bat Algorithm (BA) applied to discover the control parameters. In this scenario, this paper considers the minimization of real power generation cost with emission as an objective. Further, to improve the power system performance and reduction in the emission, two of the thermal plants were replaced with wind power plants. In addition, to boost the voltage profile, Static VAR Compensator (SVC) has been integrated. The proposed case study, i.e., considering wind plant and SVC with BA, is applied on the IEEE30 bus system. Due to the incorporation of wind plants into the system, the emission output is reduced, and with the application of SVC voltage profile improved.


2013 ◽  
Vol 347-350 ◽  
pp. 1945-1948
Author(s):  
Jian Xu ◽  
Xin Yao

Fourier algorithm can be effective utilized in the Microcomputer relay protection to filter out Harmonic component in the AC signal .but the drawback is that not filter attenuation DC component. it may be affect the computation accuracy of the entire system .and it is also reduce the efficiency of the system. In this paper ,we combined with the actual project ,on the basis of analysis of the full-wave Fourier algorithm ,for the problem of it can not filter decaying a periodic component ,we proposed an improved algorithm, and combined with MATLAB simulation ,the results show that the improved algorithm has the advantages of high accuracy and the algorithm is simple. In the microcomputer relay protection of the power system need to handle all kinds of signals, provide the necessary information for the implementation of protection. however, With the rapid development of computer technology and the continuous research of computer algorithms, a lot of actual power system protection device has been widely used in our life, on the one hand, these devices reduce the complexity of building hardware circuit, on the other hand ,it can make full use of the filter function about some algorithms have itself. The most important is that it can avoid the problem of instability and low efficiency with some filter circuit. But, this characteristic need the algorithms has a high precision [2,3]. The algorithm is set up in the microcomputer protection is a mathematical model for achieve some specific function. and write the corresponding computer applications according to this model. Then do some specific mathematical operations with these digital signals will achieve the purpose of protection. At present, the widely used full wave Fourier algorithm has a function of filtering DC component and harmonic component[4],but it can not filtering the decaying DC component in the system. It will be cause a certain interference and influence to the whole system in the practical application, the result is that led to the precision of the operation drop and lose the meaning of the protecting. In this paper, combined with specific engineering example give an improved calculation method. Through example of simulation has proved that using this algorithm can accurately figure out fundamental component and harmonic component, and it has the advantage of algorithm simple and high accuracy [5].


2011 ◽  
Vol 317-319 ◽  
pp. 1241-1244
Author(s):  
You Jie Ma ◽  
Ya Guang Yang ◽  
Xue Song Zhou

This document mainly analyses the sources of harmonic and harmonic hazards in power system. The article mainly from a few key links of power system which are electric power capacitor, power transformer, electric motors, relay protection to illustrate harmonic hazards and described harmonic treatment methods.


2013 ◽  
Vol 811 ◽  
pp. 631-634
Author(s):  
Xue Song Zhou ◽  
Zhao Hao Hou ◽  
You Jie Ma

This paper proposes a general overview of distribution network automation technology. With the continuous development of society and economy, the distribution network automation has become the trend and developing direction of electric power system. As the end part of the electric power system, the distribution network is directly connected to the consumers and plays a vital role in improving the quality and reliability of power supply. In order to provide reference for improving the reliability of distribution network and to speed up the development of distribution network automation, this paper analyses the system structure, development status and trend of distribution network automation technology.


2013 ◽  
Vol 341-342 ◽  
pp. 1423-1428
Author(s):  
Xiao Ping Xiong ◽  
Jing Jie Hu ◽  
Qiang Fu

Shunt capacitor is a main measure to reactive power compensation of power system, which has the advantages of flexibility and economy. In order to guarantee the safety of shunt capacitor, the methods for protecting against over-voltage, under-voltage, over-current and unbalance in circuits according to the different operation modes are used. This paper in detail introduces unbalance protection ways under different connection modes of capacitor group. It is analyzed and calculated that the unbalanced current and voltage with the effects of fault capacitor units, components and fuses on capacitor bank as well through a case of unbalance computation of shunt capacitor banks (SCB) of ungrounded single star with external fuse. It is indicated by PSCAD simulation analysis that the result of theory calculation is the same as the simulation, which provides theory basis of setting the tripping point and alarm point of relay protection.