scholarly journals Soft Capacitive Pressure Sensor with Enhanced Sensitivity assisted by ZnO NW Interlayers and Airgap

2022 ◽  
pp. 1-1
Author(s):  
Yogeenth Kumaresan ◽  
Sihang Ma ◽  
Oliver Ozioko ◽  
Ravinder Dahiya
2009 ◽  
Vol 74 ◽  
pp. 239-242 ◽  
Author(s):  
Mitra Damghanian ◽  
Burhanuddin Yeop Majlis

A novel MEMS capacitive pressure sensor array is designed and fabricated for fingerprint acquisition application. Based on analytical investigations and FEM analysis, the designed structure of pressure sensor cells assist from an aluminum clamped-clamped wide beam as the movable electrode of variant capacitor, instead of usual membrane structure. A rectangular base T-shape protrusion is also used on top of the deflecting electrode to concentrate pressure and increase the sensitivity. Proven by the real test of the fabricated sensor structure, this design has enhanced sensitivity and linearity of the device compared to all membrane based reported prototypes without crossing the dpi limits. Structural modifications have resulted in a simpler fabrication process as well.


2020 ◽  
Vol 8 (4) ◽  
pp. 296-307
Author(s):  
Konstantin Krestovnikov ◽  
Aleksei Erashov ◽  
Аleksandr Bykov

This paper presents development of pressure sensor array with capacitance-type unit sensors, with scalable number of cells. Different assemblies of unit pressure sensors and their arrays were considered, their characteristics and fabrication methods were investigated. The structure of primary pressure transducer (PPT) array was presented; its operating principle of array was illustrated, calculated reference ratios were derived. The interface circuit, allowing to transform the changes in the primary transducer capacitance into voltage level variations, was proposed. A prototype sensor was implemented; the dependency of output signal power from the applied force was empirically obtained. In the range under 30 N it exhibited a linear pattern. The sensitivity of the array cells to the applied pressure is in the range 134.56..160.35. The measured drift of the output signals from the array cells after 10,000 loading cycles was 1.39%. For developed prototype of the pressure sensor array, based on the experimental data, the average signal-to-noise ratio over the cells was calculated, and equaled 63.47 dB. The proposed prototype was fabricated of easily available materials. It is relatively inexpensive and requires no fine-tuning of each individual cell. Capacitance-type operation type, compared to piezoresistive one, ensures greater stability of the output signal. The scalability and adjustability of cell parameters are achieved with layered sensor structure. The pressure sensor array, presented in this paper, can be utilized in various robotic systems.


2021 ◽  
pp. 1-1
Author(s):  
Valliammai Palaniappan ◽  
Masoud Panahi ◽  
Dinesh Maddipatla ◽  
Xingzhe Zhang ◽  
Simin Masihi ◽  
...  

1996 ◽  
Vol 32 (2) ◽  
pp. 128 ◽  
Author(s):  
M.G. Xu ◽  
H. Geiger ◽  
J.P. Dakin

Sign in / Sign up

Export Citation Format

Share Document