Development of two dimensional thermal neutron flux monitor using multi-wire proportional counter for boron neutron capture therapy

Author(s):  
Hiroki Tanaka ◽  
Yoshinori Sakurai ◽  
Minoru Suzuki ◽  
Shin-ichiro Masunaga ◽  
Masahiro Hino ◽  
...  
1978 ◽  
Vol 75 (2) ◽  
pp. 243 ◽  
Author(s):  
Yoshinori Hayakawa ◽  
Susumu Harasawa ◽  
Atsushi Nakamoto ◽  
Kazuyoshi Amano ◽  
Hiroshi Hatanaka ◽  
...  

2016 ◽  
Vol 1 (1) ◽  
pp. 1
Author(s):  
Yohannes Sardjono ◽  
Susilo Widodo ◽  
Irhas Irhas ◽  
Hilmi Tantawy

Boron Neutron Capture Therapy (BNCT) is an advanced form of radiotherapy technique that is potentially superior to all conventional techniques for cancer treatment, as it is targeted at killing individual cancerous cells with minimal damage to surrounding healthy cells. After decades of development, BNCT has reached clinical-trial stages in several countries, mainly for treating challenging cancers such as malignant brain tumors. The Indonesian consortium of BNCT already developed of the design BNCT for many cases of type cancers using many neutron sources. The main objective of the Indonesian consortium BNCT are the development of BNCT technology package which consists of a non nuclear reactor neutron source based on cyclotron and compact neutron generator technique, advanced boron-carrying pharmaceutical, and user-friendly treatment platform with automatic operation and feedback system as well as commercialization of the BNCT though franchised network of BNCT clinics worldwide. The Indonesian consortium BNCT will offering to participate in Boron carrier pharmaceuticals development and testing, development of cyclotron and compact neutron generators and provision of neutrons from the 100 kW Kartini Research Reactor to guide and to validate compact neutron generator development. Studies were carried out to design a collimator which results in epithermal neutron beam for Boron Neutron Capture Therapy (BNCT) at the Kartini Research Reactor by means of Monte Carlo N-Particle 5 (MCNP5) codes. Reactor within 100 kW of output thermal power was used as the neutron source. The design criteria were based on the IAEA’s recommendation. All materials used were varied in size, according to the value of mean free path for each. Monte Carlo simulations indicated that by using 5 cm thick of Ni as collimator wall, 60 cm thick of Al as moderator, 15 cm thick of 60Ni as filter, 1,5 cm thick of Bi as "-ray shielding, 3 cm thick of 6Li2CO3-polyethylene as beam delimiter, with 3-5 cm varied aperture size, epithermal neutron beam with minimum flux of 7,8 x 108 n.cm-2.s-1, maximum fast neutron and "-ray components of, respectively, 1,9 x 10-13 Gy.cm2.n-1 and 1,8 x 10-13 Gy.cm2.n-1, maximum thermal neutron per epithermal neutron ratio of 0,009, and beam minimum directionality of 0,72, could be produced. The beam did not fully pass the IAEA’s criteria, since the epithermal neutron flux was still below the recommended value, 1,0 x 109 n.cm-2.s-1. Nonetheless, it was still usable with epithermal neutron flux exceeded 5 x 108 n.cm-2.s-1. When this collimator was surrounded by 8 cm thick of graphite, the characteristics of the beam became better that it passed all IAEA’s criteria with epithermal neutron flux up to 1,7 x 109 n.cm-2.s-1. it is still feasible for BNCT in vivo experiment and study of many cases cancer type i.e.; liver and lung curcinoma. In this case, thermal neutron produced by model of Collimated Thermal Column Kartini Research Nuclear Reactor, Yogyakarta. Sodium boroncaptate (BSH) was used as in this research. BSH had effected in liver for radiation quality factor as 0.8 in health tissue and 2.5 in cancer tissue. Modelling organ and source used liver organ who contain of cancer tissue and research reactor. Variation of boron concentration was 20, 25, 30, 35, 40, 45, and 47 $g/g cancer. Output of MCNP calculation were neutron scattering dose, gamma ray dose and neutron flux from reactor. Given the advantages of low density owned by lungs, hence BNCT is a solid option that can be utilized to eradicate the cell cancer in lungs. Modelling organ and neutron source for lung carcinoma was used Compact Neutron Generator (CNG) by deuterium-tritium which was used is boronophenylalanine (BPA). The concentration of boron-10 compound was varied in the study; i.e. the variations were 20; 25; 30; 35; 40 and 45 μg.g-1 cancer tissues. Ideally, the primary dose which is solemnly expected to contribute in the therapy is alpha dose, but the secondary dose; i.e. neutron scattering dose, proton dose and gamma dose that are caused due to the interaction of thermal neutron with the spectra of tissue can not be simply omitted. Thus, the desired output of MCNPX; i.e. tally, were thermal and epithermal neutron flux, neutron and photon dose. The liver study variation of boron concentration result dose rate to every variation were0,042; 0,050; 0,058; 0,067; 0,074; 0,082; 0,085 Gy/sec. Irradiation time who need to every concentration were 1194,687 sec (19 min 54 sec);999,645 sec (16 min 39 sec); 858,746 sec (14 min 19 sec); 743,810 sec (12 min 24 sec); 675,156 sec (11 min 15 sec); 608,480 sec (10 min 8 sec); 585,807sec (9 min 45 sec). The lung carcinoma study variations of boron-10 concentration in tissue resulted in the dose rate of each variables respectively were 0.003145, 0.003657, 0.00359, 0.00385, 0.00438 and 0.00476 Gy.sec-1 . The irradiated time needed for therapy for each variables respectively were 375.34, 357.55, 287.58, 284.95, 237.84 and 219.84 minutes.


1981 ◽  
Vol 88 (1) ◽  
pp. 187 ◽  
Author(s):  
Susumu Harasawa ◽  
Atsushi Nakamoto ◽  
Yoshinori Hayakawa ◽  
Jun Egawa ◽  
Otohiko Aizawa ◽  
...  

Author(s):  
Safwan Shalbi ◽  
Norazlianie Sazali ◽  
Wan Norharyati Wan Salleh

The thermal column at the TRIGA PUSPATI (RTP) research reactor can produce thermal neutron. However, the optimization on the thermal neutron flux produced should be performed to gain a sufficient thermal neutron for boron neutron capture therapy purpose. Thus, the objective of this review is to optimize the thermal neutron flux by designing the collimator with different materials at the thermal column. In order to fulfil the requirement, set by the IAEA standard, the study of Boron Neutron Capture Therapy (BNCT) around the world was being reviewed to study the suitable measurement, material, design, and modification for BNCT at the thermal column of TRIGA MARK-II, Malaysia. Initially, the BNCT mechanisms and history was review. Then, this paper review on the design and modifications for BNCT purpose around the world. Based on this review, suitable material and design can be used for the BNCT in Malaysia. Moreover, this paper also reviews the current status of BNCT at the RTP with the measurement of the thermal neutron flux was conducted along the thermal column at 250 kW. The thermal column of RTP was divided into 3 phases (Phase 1, Phase 2 and Phase 3) so that an accurate measurement can be obtained by using gold foil activation method. This value was used as a benchmark for the neutron flux produced from the thermal column. The reviewed demonstrated that the final thermal neutron flux produced was significantly for BNCT purpose.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Satoshi Nakamura ◽  
Hiroshi Igaki ◽  
Masashi Ito ◽  
Shoji Imamichi ◽  
Tairo Kashihara ◽  
...  

AbstractAn accelerator-based boron neutron capture therapy (BNCT) system employing a solid-state Li target can achieve sufficient neutron flux for treatment although the neutron flux is reduced over the lifetime of its target. In this study, the reduction was examined in the five targets, and a model was then established to represent the neutron flux. In each target, a reduction in neutron flux was observed based on the integrated proton charge on the target, and its reduction reached 28% after the integrated proton charge of 2.52 × 106 mC was delivered to the target in the system. The calculated neutron flux acquired by the model was compared to the measured neutron flux based on an integrated proton charge, and the mean discrepancies were less than 0.1% in all the targets investigated. These discrepancies were comparable among the five targets examined. Thus, the reduction of the neutron flux can be represented by the model. Additionally, by adequately revising the model, it may be applicable to other BNCT systems employing a Li target, thus furthering research in this direction. Therefore, the established model will play an important role in the accelerator-based BNCT system with a solid-state Li target in controlling neutron delivery and understanding the neutron output characteristics.


2018 ◽  
Vol 35 (3) ◽  
pp. 183-186
Author(s):  
Arief Fauzi ◽  
Afifah Hana Tsurayya ◽  
Ahmad Faisal Harish ◽  
Gede Sutresna Wijaya

A design of beam shaping assembly (BSA) installed on cyclotron 30 MeV model neutron source for boron neutron capture therapy (BNCT) has been optimized using simulator software of Monte Carlo N-Particle Extended (MCNPX). The Beryllium target with thickness of 0.55 cm is simulated to be bombarded with 30 MeV of proton beam. In this design, the parameter regarding beam characteristics for BNCT treatment has been improved, which is ratio of fast neutron dose and epithermal neutron flux. TiF3 is replaced to 30 cm of 27Al as moderator, and 1.5 cm of 32S is combined with 28 cm of 60Ni as neutron filter. Eventually, this design produces epithermal neutron flux of 2.33 × 109, ratio between fast neutron dose and epithermal neutron flux of 2.12 × 10-13,ratio between gamma dose and epithermal neutron flux of 1.00 × 10-13, ratio between thermal neutron flux and epithermal neutron flux is 0.047, and ration between particle current and total neutron flux is 0.56.


Sign in / Sign up

Export Citation Format

Share Document