Preliminary comparative results on axial resolution using both coded excitation and conventional pulses in ultrasound A-mode scan

Author(s):  
T. M. Machado ◽  
E. T. Costa
2007 ◽  
Vol 33 (8) ◽  
pp. 1296-1308 ◽  
Author(s):  
Joanne Cowe ◽  
John Gittins ◽  
David H. Evans

2012 ◽  
Vol 2012 ◽  
pp. 1-16 ◽  
Author(s):  
Joshua S. Ullom ◽  
Michael L. Oelze ◽  
Jose R. Sanchez

A method for improving the contrast-to-noise ratio (CNR) while maintaining the −6 dB axial resolution of ultrasonic B-mode images is proposed. The technique proposed is known as eREC-FC, which enhances a recently developed REC-FC technique. REC-FC is a combination of the coded excitation technique known as resolution enhancement compression (REC) and the speckle-reduction technique frequency compounding (FC). In REC-FC, image CNR is improved but at the expense of a reduction in axial resolution. However, by compounding various REC-FC images made from various subband widths, the tradeoff between axial resolution and CNR enhancement can be extended. Further improvements in CNR can be obtained by applying postprocessing despeckling filters to the eREC-FC B-mode images. The despeckling filters evaluated were the following: median, Lee, homogeneous mask area, geometric, and speckle-reducing anisotropic diffusion (SRAD). Simulations and experimental measurements were conducted with a single-element transducer (f/2.66) having a center frequency of 2.25 MHz and a −3 dB bandwidth of 50%. In simulations and experiments, the eREC-FC technique resulted in the same axial resolution that would be typically observed with conventional excitation with a pulse. Moreover, increases in CNR of 348% were obtained in experiments when comparing eREC-FC with a Lee filter to conventional pulsing methods.


1990 ◽  
Vol 29 (05) ◽  
pp. 215-220 ◽  
Author(s):  
R. Benning ◽  
K. Nagel ◽  
M. Jugenheimer ◽  
S. Fischer ◽  
S. Worthmann ◽  
...  

A new 99mTc-labelled tracer (99mTc-Sestanriibi) was used for the first time to demonstrate the perfusion of the skeletal muscle. In 16 patients with obstructive atherosclerosis of the lower limbs the change of perfusion of thigh and lower leg was studied with SPECT before and after vascular surgery (n = 11) or percutaneous transluminal angioplasty (n = 5). Comparative results of scintigraphic measurements and clinical observations (ancle-arm pressure, treadmill test) in 10 surgical patients (14 operated legs) showed correct positive or negative results in 86% (12/14).


2015 ◽  
Vol 24 (2) ◽  
pp. 171-176 ◽  
Author(s):  
Elena Mirela Ionescu ◽  
Tudor Nicolaie ◽  
Serban Ion Gologan ◽  
Ana Mocanu ◽  
Cristina Ditescu ◽  
...  

Background & Aims: Even though Romania has one of the highest incidence and mortality in colorectal cancer (CRC) in Europe, there is currently no organized screening program. We aimed to assess the results of our opportunistic CRC screening using colonoscopy.Methods: A single center retrospective study to include all opportunistic screening colonoscopies performed in two 18 month periods (2007-2008 and 2012-2013) was designed. All asymptomatic individuals without a personal or family history of adenoma or CRC and with complete colonoscopy performed in these two time periods were included.Results: We included 1,807 individuals, 882 in the first period, 925 in the second period. There were 389 individuals aged below 50, 1,351 between 50 and 75 and 67 older than 75 years. There were 956 women (52.9%), with a mean age of 58.5 (median 59, range 23-97). The detection rates were 12.6% for adenomas (6.1% for advanced adenoma) and 3.4% for adenocarcinoma. Adenoma incidence (4.9% in subjects under 50, 14.7% in those aged 50 to 75, and 16.4% in those older than 75, p<0.0001) and size (6.3mm in subjects younger than 50, 9.2mm in those 50 to 75 and 10.8mm in those older than 75, p=0.015) significantly increased with age. Adenoma incidence increased in the second period (14.8% vs. 10.3%, p=0.005), while adenoma size decreased in the second period (8.4mm vs. 10mm, p=0.006). There were no procedure related complications.Conclusions: The neoplasia detection rate was 16% (12.6% adenoma, 3.4% adenocarcinoma). Adenoma incidence and size increased with age in both cohorts. In the second screening period significantly more and smaller adenomas were detected.


Sign in / Sign up

Export Citation Format

Share Document