Online wideband identification of single-phase AC power grid impedances using an existing grid-tied power electronic inverter

Author(s):  
Antonino Riccobono ◽  
Syed Khurram Abbas Naqvi ◽  
Antonello Monti ◽  
Tommaso Caldognetto ◽  
Jonathan Siegers ◽  
...  
Author(s):  
Salam Waley Shneen ◽  
Fatin Nabeel Abdullah ◽  
Dina Harith Shaker

This work is presenting under the title simulation model of single phase PWM inverter by using MATLAB/Simulink. There are many researchers’ works in this field with the different ways because it is important field and it has many applications. The converter DC power to AC power for any system that mean it need the power electronic device (inverter). The inverter is using when the source DC power and the load AC power. In this work, the simulation system includes the source 300V DC power, inverter, LC filter and load (R). The simulation result shows the waveform of all part in this system like input and output current and voltage.


2021 ◽  
Vol 92 (7) ◽  
pp. 401-403
Author(s):  
V. N. Shemyakin ◽  
M. A. Mastepanenko ◽  
V. Ya. Khorolsky ◽  
A. V. Efanov ◽  
I. N. Vorotnikov

This study investigated current harmonic distortions emanating from domestic non-linear loads which have adverse deleterious effects on installed low voltage switchgears such as transformers and conductors. The study examined harmonic distortions emanating from dominant domestic nonlinear loads such as microwave, TV set, radio, fridge, video player and compacted fluorescence bulbs (CFLs) using a power quality equipment. From the results obtained, it was noted that there is need to mitigate harmonic distortions generated by domestic loads at point of common coupling (PCC). It is pertinent to mention that the recent study on supplied loads carried out in Kenya power grid shows that above 67% of power end users are domestic consumers. Under current last mile initiative and Global Partnership on Output Based Aid (GPOBA), unprecedented increase of domestic loads connected to the power grid is predicted. It is worth pointing out that most of these domestic loads have switch mode power supplies (SMPS) which have inherent characteristics of distorting current waveform which causes voltage distortions, over-heating of neutral conductors and premature failure of distribution transformers. Further, most of these loads have two modes; standby/sleep mode and operating mode. Results shows that the two modes generate current harmonic distortions which stream back to power utility network through the service cable. Recently, engineers have designed electronic devices that consume less power. These devices draw current in pulses rather than sinusoidal waveform. As a result, the quality of power supplies continues to deteriorate hence adversely affecting the installed low voltage switchgears such as distribution transformers. Although various mitigation measures exist to reduce the effects of harmonic distortions, this paper proposes a single phase active filter as an optimal solution for attenuating the harmonics emanating from domestic non-linear loads.


Sign in / Sign up

Export Citation Format

Share Document