Cross-layer signal monitoring in an optical packet-switching test-bed via real-time burst sampling

Author(s):  
Caroline P. Lai ◽  
Ali Fard ◽  
Brandon Buckley ◽  
Bahram Jalali ◽  
Keren Bergman
2012 ◽  
Vol 20 (26) ◽  
pp. B535 ◽  
Author(s):  
Satoshi Shinada ◽  
Moriya Nakamura ◽  
Yukiyoshi Kamio ◽  
Naoya Wada

IEEE Access ◽  
2021 ◽  
pp. 1-1
Author(s):  
Hafsa Bibi ◽  
Farrukh Zeeshan Khan ◽  
Muneer Ahmad ◽  
Anum Naseem ◽  
Tomasz Holynski ◽  
...  

2021 ◽  
pp. 107754632110191
Author(s):  
Farzam Tajdari ◽  
Naeim Ebrahimi Toulkani

Aiming at operating optimally minimizing error of tracking and designing control effort, this study presents a novel generalizable methodology of an optimal torque control for a 6-degree-of-freedom Stewart platform with rotary actuators. In the proposed approach, a linear quadratic integral regulator with the least sensitivity to controller parameter choices is designed, associated with an online artificial neural network gain tuning. The nonlinear system is implemented in ADAMS, and the controller is formulated in MATLAB to minimize the real-time tracking error robustly. To validate the controller performance, MATLAB and ADAMS are linked together and the performance of the controller on the simulated system is validated as real time. Practically, the Stewart robot is fabricated and the proposed controller is implemented. The method is assessed by simulation experiments, exhibiting the viability of the developed methodology and highlighting an improvement of 45% averagely, from the optimum and zero-error convergence points of view. Consequently, the experiment results allow demonstrating the robustness of the controller method, in the presence of the motor torque saturation, the uncertainties, and unknown disturbances such as intrinsic properties of the real test bed.


Author(s):  
Wolf Schulze ◽  
Maurizio Zajadatz ◽  
Michael Suriyah ◽  
Thomas Leibfried

AbstractA test bed for the evaluation of novel control methods of inverters for renewable power generation is presented. The behavior of grid-following and grid-forming control in a test scenario is studied and compared.Using a real-time capable control platform with a cycle time of 50 µs, control methods developed with Matlab/Simulink can be implemented. For simplicity, a three-phase 4‑quadrant voltage amplifier is used instead of an inverter. Thus, the use of modulation and switched power semiconductors can be avoided. In order to show a realistic behavior of a grid-side filter, passive components can be automatically connected as L‑, LC- or LCL-filter. The test bed has a nominal active power of 43.6 kW and a nominal voltage of 400 V.As state-of-the-art grid-following control method, a current control in the d/q-system is implemented in the test bed. A virtual synchronous machine, the Synchronverter, is used as grid-forming control method. In combination with a frequency-variable grid emulation, the behavior of both control methods is studied in the event of a load connection in an island grid environment.


Sign in / Sign up

Export Citation Format

Share Document