New Perspectives on Power Control of AC Microgrid Considering Operation Cost and Efficiency

Author(s):  
Wenbin Yuan ◽  
Yanbo Wang ◽  
Zhe Chen
Electronics ◽  
2021 ◽  
Vol 10 (24) ◽  
pp. 3095
Author(s):  
Shameem Ahmad ◽  
Saad Mekhilef ◽  
Hazlie Mokhlis ◽  
Mazaher Karimi ◽  
Alireza Pourdaryaei ◽  
...  

A voltage source inverter (VSI) is the key component of grid-tied AC Microgrid (MG) which requires a fast response, and stable, robust controllers to ensure efficient operation. In this paper, a fuzzy logic controller (FLC)-based direct power control (DPC) method for photovoltaic (PV) VSI was proposed, which was modelled by modulating MG’s point of common coupling (PCC) voltage. This paper also introduces a modified grid synchronization method through the direct power calculation of PCC voltage and current, instead of using a conventional phase-locked loop (PLL) system. FLC is used to minimize the errors between the calculated and reference powers to generate the required control signals for the VSI through sinusoidal pulse width modulation (SPWM). The proposed FLC-based DPC (FLDPC) method has shown better tracking performance with less computational time, compared with the conventional MG power control methods, due to the elimination of PLL and the use of a single power control loop. In addition, due to the use of FLC, the proposed FLDPC exhibited negligible steady-state oscillations in the output power of MG’s PV-VSI. The proposed FLDPC method performance was validated by conducting real-time simulations through real time digital simulator (RTDS). The results have demonstrated that the proposed FLDPC method has a better reference power tracking time of 0.03 s along with reduction in power ripples and less current total harmonic distortion (THD) of 1.59%.


2021 ◽  
Vol 03 (03) ◽  
pp. 1-1
Author(s):  
Xiuhui Tang ◽  
◽  
Daming Zhang ◽  
Hua Chai ◽  
◽  
...  

In AC microgrid systems, technical issues resulting from the power control effect are the power control method efficiency and the filter resonance since voltage-frequency interference and filtering resonance may cause significant control input reduction and oscillation. A simple and robust solution is to regulate active power flow by adding an optimal passive damping resistor. The optimal LCL filter parameterization process in this paper provides an innovative approach to obtain the optimal quality factor and the optimal damping resistor. The amplitude responses of resonant frequency and high frequency are involved in the cost function. Simulations of various cases are conducted in MATLAB/Simulink. The key advantages of this procedure include flattened admittance peak, weakened high frequency decay, and less damping loss. Through the method in this paper, the optimal passive-damped filter parameters can be calculated in an efficient manner, while the power can be regulated and tracked in a simplified way, and the performance of the control strategy is improved.


Sign in / Sign up

Export Citation Format

Share Document