An Analysis of the Effects and Dependency of Wind Power Penetration on System Frequency Regulation

2016 ◽  
Vol 7 (1) ◽  
pp. 354-363 ◽  
Author(s):  
Nga Nguyen ◽  
Joydeep Mitra
Energies ◽  
2020 ◽  
Vol 13 (23) ◽  
pp. 6178
Author(s):  
Changgang Li ◽  
Zhi Hang ◽  
Hengxu Zhang ◽  
Qi Guo ◽  
Yihua Zhu ◽  
...  

Accompanying the continuous increase in wind power penetration, the power system inertia is reduced, and the system frequency regulation performance deteriorates. Wind turbine generators are required to participate in primary frequency regulation (PFR) to support system frequency. Here, the PFR capability of the widely-used doubly-fed induction generator (DFIG) is evaluated to estimate the participation of the DFIG in system frequency control. The frequency regulation model of the DFIG is established and briefly discussed. The equivalent PFR droop coefficient is then deduced from the model using a small signal increment method to evaluate the DFIG’s PFR capability. Key factors affecting the equivalent droop coefficient are studied, and the droop control is optimized to keep the equivalent droop coefficient in the desired range. The proposed method is verified utilizing a provincial power grid model of China.


2013 ◽  
Vol 58 (36) ◽  
pp. 4557-4565 ◽  
Author(s):  
HaiShun Sun ◽  
Ju Liu ◽  
JinYu Wen ◽  
ShiJie Cheng ◽  
Cheng Luo ◽  
...  

2020 ◽  
Vol 12 (23) ◽  
pp. 9850
Author(s):  
Mengqi Qing ◽  
Fei Tang ◽  
Fusuo Liu ◽  
Dichen Liu ◽  
Nianchun Du ◽  
...  

With the increasing wind power in power systems and the wide application of frequency regulation technology, the accurate calculation of the limit wind power capacity in systems is critical to ensure the stability of the frequency and guide the planning of wind power sources. This paper proposes an analytical method for calculating the maximum wind generation penetration under the constraints of frequency regulation control and frequency stability taking doubly fed induction generator as an example. Firstly, the frequency-domain dynamic model of the doubly fed induction generator is established considering the supplementary frequency proportion-differentiation control under small disturbance. The equivalent inertia time constant of the doubly fed induction generator is calculated. On this basis, the frequency response model of the power system with the consideration of wind power integration in frequency regulation control is constructed. Then, the frequency-domain analytical solution of the system frequency is obtained. Finally, with the constraint by the steady-state deviation and dynamic change rate of the system frequency, the maximum wind generation penetration is analytically solved. The accuracy of the proposed analytical calculation method for the limit value of the percentage of wind power is verified by MATLAB/Simulink.


Author(s):  
Rafael Sebastián ◽  
Jerónimo Quesada

"This study presents the modelling and dynamic simulation of an Isolated Wind Power System (IWPS) consisting of a Wind Turbine Generator (WTG), a synchronous machine (SM), consumer load, dump load (DL) and a Battery Energy Storage System (BESS). First the IWPS architecture and the dynamic models of the IWPS components are described. Second, the control requirements for frequency regulation of the IWPS are studied and a PID regulator to govern the active power stored+dumped by the BESS+DL combination or supplied by the BESS along with a power sharing algorithm between the BESS and DL is presented. Finally the IWPS is simulated facing to variations to load and WTG power. The simulation results are given showing graphs of the main electrical variables in the IWPS: system frequency and voltage and active power in each component. The results show how the BESS or BESS+DL combination regulates correctly the isolated system frequency. The results also show that the BESS improves the IWPS reliability when compared with the frequency control obtained using only the DL."


Energies ◽  
2017 ◽  
Vol 10 (11) ◽  
pp. 1797 ◽  
Author(s):  
Yi Tang ◽  
Jianfeng Dai ◽  
Jia Ning ◽  
Jie Dang ◽  
Yan Li ◽  
...  

Author(s):  
Cheng Yan ◽  
Yi Tang ◽  
Jianfeng Dai ◽  
Chenggen Wang ◽  
Shengjun Wu

AbstractLarge-scale integration of wind power generation decreases the equivalent inertia of a power system, and thus makes frequency stability control challenging. However, given the irregular, nonlinear, and non-stationary characteristics of wind power, significant challenges arise in making wind power generation participate in system frequency regulation. Hence, it is important to explore wind power frequency regulation potential and its uncertainty. This paper proposes an innovative uncertainty modeling method based on mixed skew generalized error distribution for wind power frequency regulation potential. The mapping relationship between wind speed and the associated frequency regulation potential is established, and key parameters of the wind turbine model are identified to predict the wind power frequency regulation potential. Furthermore, the prediction error distribution of the frequency regulation potential is obtained from the mixed skew model. Because of the characteristics of error partition, the error distribution model and predicted values at different wind speed sections are summarized to generate the uncertainty interval of wind power frequency regulation potential. Numerical experiments demonstrate that the proposed model outperforms other state-of-the-art contrastive models in terms of the refined degree of fitting error distribution characteristics. The proposed model only requires the wind speed prediction sequence to accurately model the uncertainty interval. This should be of great significance for rationally optimizing system frequency regulation resources and reducing redundant backup.


2018 ◽  
Vol 10 (08) ◽  
pp. 366-382
Author(s):  
Zijian Ye ◽  
Yuyan Xie ◽  
Haochuan Zhu

Sign in / Sign up

Export Citation Format

Share Document