Super high‐flux hemodialysis provides comparable effectiveness with high‐volume postdilution online hemodiafiltration in removing protein‐bound and middle‐molecule uremic toxins: A prospective cross‐over randomized controlled trial

Author(s):  
Theerachai Thammathiwat ◽  
Khajohn Tiranathanagul ◽  
Maneerut Limjariyakul ◽  
Pajaree Chariyavilaskul ◽  
Kullaya Takkavatakarn ◽  
...  
2020 ◽  
Vol 35 (Supplement_3) ◽  
Author(s):  
Jordana Lima ◽  
Murilo Guedes ◽  
Silvia Rodrigues ◽  
Ana Clara Flórido ◽  
Ana Beatriz Barra ◽  
...  

Abstract Background and Aims Online High-Volume Hemodiafiltration (OL-HDF) combines convective and diffusive clearances and is associated with better outcomes compared to standard hemodialysis (HD). Although HDF has been shown to improve the clearance and pre-dialysis concentration of middle size uremic toxins, little is known about its effect on concentration of protein-bound uremic toxins (PBUT), particularly in comparison to high-flux HD. Here, we investigated whether high-volume post-dilution OL-HDF impacts pre-dialysis plasma levels of PBUT indoxyl sulfate (IxS), p-cresyl sulfate (pCS) and indole 3-acetic acid (IAA) compared to high-flux HD over time, since accumulation of these PBUT has been associated with increased overall mortality of CKD patients. Method This is post hoc analysis of the multicentric randomized controlled trial (RCT) studying the impact of post-dilution high-volume OL-HDF versus high-flux HD on measured physical activity (HDFit - clinicalTrials.gov: NCT02787161), which included clinically stable HD patients with a vintage >3 to <24 months. Total plasma levels of IxS, pCS and IAA were determined by high performance liquid chromatography (HPLC) with fluorescence detection at baseline, 3 and 6 months. The difference between HDF and HD in respect to changes in the PBUT concentrations during the follow up, analyzed using linear mixed effect models, was compared. Results are presented as mean differences between groups in the change from baseline along with 95% confidence intervals (CI). Results 193 patients (mean age 53 years old, 70% males and 60% white – no differences between groups) were analyzed. There were no differences between HD and OL-HDF groups regarding clinical and biochemical characteristics at the baseline. In the OL-HDF group, 99% of patients achieved a convective volume higher than 22 L and both groups had similar dialysis session duration and blood flows throughout the follow up. The mean differences (95% CI) in concentrations over time for PBUTs among HDF and HD groups are shown in Figure 1. HDF group presented a significantly lower trajectory of IxS levels and a lower trajectory of pCS levels than HD group. Trajectories of IAA levels were not different between groups. Conclusion OL-HDF reduced the pre-dialysis concentration of IxS and pCS through 6 months-period compared to high-flux HD.


2019 ◽  
Vol 49 (1-2) ◽  
pp. 168-177
Author(s):  
Maggie Han ◽  
Murilo Guedes ◽  
John Larkin ◽  
Jochen G. Raimann ◽  
Ana Beatriz Lesqueves Barra ◽  
...  

Introduction: Dialysis patients suffer from poor sleep duration and quality. We examined the self-reported sleep duration in patients randomized to either high-volume hemodiafiltration (HDF) or high flux hemodialysis (HD). Methods: Patients from 13 Brazilian dialysis clinics were enrolled in the HDFIT randomized controlled trial (RCT) investigating the impact of HDF on physical activity and self-reported outcomes. Self-reported sleep duration was taken from patient diaries recording sleep start and end time over a week during baseline, months 3 and 6, respectively. Sleep duration was analyzed by shift and nights relative to dialysis. Results: The HDFIT study enrolled 197 patients; sleep data were available in 173 patients (87 HD; 86 HDF). Patients’ age was 53 ± 15 years, 57% were white, 72% were male, 34% had diabetes, Kt/V was 1.54 ± 0.40, and albumin 3.97 ± 0.36 g/dL. Most patients reported sleeping 510–530 min/night. At 3 months, HDF patients slept 513 ± 71 min/night, HD patients 518 ± 76 min/night. At 6 months, HDF patients slept 532 ± 74 min/night, HD patients 519 ± 80 min/night. At baseline, 1st shift patients slept 406 ± 86 min the night before HD, 534 ± 64 min the night after HD, and 496 ± 99 min the night between 2 non-HD days. Compared to patients in the 2nd and 3rd shifts, patients dialyzed in the 1st shift slept less in the night before dialysis. Similar patterns were seen after 3 and 6 months. Conclusion: In our RCT, the dialysis modality (HDF vs. HD) had no effect on self-reported sleep duration. In both groups, dialysis in the 1st shift adversely affected self reported sleep duration.


PLoS ONE ◽  
2021 ◽  
Vol 16 (4) ◽  
pp. e0249490
Author(s):  
Michael Sey ◽  
Brian Yan ◽  
Cassandra McDonald ◽  
Dan Segal ◽  
Joshua Friedland ◽  
...  

Background The optimal dose of simethicone before capsule endoscopy is unknown. Prior studies have reported inconsistent cleansing, with some showing improved visualization only in the proximal small intestine. We hypothesized a higher volume of simethicone may improve cleansing and diagnostic yield, especially in the distal small bowel. Methods A phase III randomized controlled trial was conducted comparing high volume (1125 mg simethicone in 750 ml water) versus standard volume (300 mg simethicone in 200 ml water) solutions, both at 1.5 mg/ml. The primary outcome was adequate bowel preparation, defined as a KOrea-CanaDA (KODA) score >2.25, overall and stratified by the proximal and distal half of the small bowel. Secondary outcomes included mean KODA score, diagnostic yield, completion rate, and adverse events. All analyses were intention-to-treat. Results A total of 167 patients were randomized (mean (SD) age 58.7 (15.7), 54% female) and the most common indication was obscure gastrointestinal bleeding (71.7%). Adequate cleansing was achieved in 39 (50%) patients in the high volume group and in 39 (48%) patients in the standard volume group (RR 1.04, 95% CI 0.76–1.43, p = 0.82), with no differences observed in the proximal half (71% vs 64%, p = 0.40) or the distal half -of the small bowel (36% vs. 37%, p = 0.88). There was no differences in the mean (SD) KODA score (2.20 (0.41) vs. 2.18 (0.44), p = 0.73), diagnostic yields (53% vs. 56%, p = 0.71), or completion rates (both 95%). One adverse event, nausea, occurred in the control group. Conclusion High volume simethicone does not improve visualization during capsule endoscopy. Clinical trial registration Clinical trial: NCT02334631.


Sign in / Sign up

Export Citation Format

Share Document