Comparing four non-invasive methods to determine the ventilatory anaerobic threshold during cardiopulmonary exercise testing in children with congenital heart or lung disease

2014 ◽  
Vol 35 (6) ◽  
pp. 451-459 ◽  
Author(s):  
Naomi. C. A. Visschers ◽  
Erik. H. Hulzebos ◽  
Marco. van Brussel ◽  
Tim. Takken
2019 ◽  
Vol 10 (3) ◽  
pp. 286-291 ◽  
Author(s):  
Jonathan N. Menachem ◽  
Nosheen Reza ◽  
Jeremy A. Mazurek ◽  
Danielle Burstein ◽  
Edo Y. Birati ◽  
...  

Introduction: Treatment of patients with adult congenital heart disease (ACHD) with advanced therapies including heart transplant (HT) is often delayed due to paucity of objective prognostic markers for the severity of heart failure (HF). While the utility of Cardiopulmonary Exercise Testing (CPET) in non-ACHD patients has been well-defined as it relates to prognosis, CPET for this purpose in ACHD is still under investigation. Methods: We performed a retrospective cohort study of 20 consecutive patients with ACHD who underwent HT between March 2010 and February 2016. Only 12 of 20 patients underwent CPET prior to transplantation. Demographics, standard measures of CPET interpretation, and 30-day and 1-year post transplantation outcomes were collected. Results: Patient Characteristics. Twenty patients with ACHD were transplanted at a median of 40 years of age (range: 23-57 years). Of the 12 patients who underwent CPET, 4 had undergone Fontan procedures, 4 had tetralogy of Fallot, 3 had d-transposition of the great arteries, and 1 had Ebstein anomaly. Thirty-day and one-year survival was 100%. All tests included in the analysis had a peak respiratory quotient _1.0. The median peak oxygen consumption per unit time (_VO2) for all diagnoses was 18.2 mL/kg/min (46% predicted), ranging from 12.2 to 22.6. Conclusion: There is a paucity of data to support best practices for patients with ACHD requiring transplantation. While it cannot be proven based on available data, it could be inferred that outcomes would have been worse or perhaps life sustaining options unavailable if providers delayed referral because of the lack of attainment of CPET-specific thresholds.


2021 ◽  
Vol 10 (1) ◽  
Author(s):  
Laura Jones ◽  
Laura Tan ◽  
Suzanne Carey-Jones ◽  
Nathan Riddell ◽  
Richard Davies ◽  
...  

Abstract Background Consumer wrist-worn wearable activity monitors are widely available, low cost and are able to provide a direct measurement of several markers of physical activity. Despite this, there is limited data on their use in perioperative risk prediction. We explored whether these wearables could accurately approximate metrics (anaerobic threshold, peak oxygen uptake and peak work) derived using formalised cardiopulmonary exercise testing (CPET) in patients undergoing high-risk surgery. Methods Patients scheduled for major elective intra-abdominal surgery and undergoing CPET were included. Physical activity levels were estimated through direct measures (step count, floors climbed and total distance travelled) obtained through continuous wear of a wrist worn activity monitor (Garmin Vivosmart HR+) for 7 days prior to surgery and self-report through completion of the short International Physical Activity Questionnaire (IPAQ). Correlations and receiver operating characteristic (ROC) curve analysis explored the relationships between parameters provided by CPET and physical activity. Device selection Our choice of consumer wearable device was made to maximise feasibility outcomes for this study. The Garmin Vivosmart HR+ had the longest battery life and best waterproof characteristics of the available low-cost devices. Results Of 55 patients invited to participate, 49 (mean age 65.3 ± 13.6 years; 32 males) were enrolled; 37 provided complete wearable data for analyses and 36 patients provided full IPAQ data. Floors climbed, total steps and total travelled as measured by the wearable device all showed moderate correlation with CPET parameters of peak oxygen uptake (peak VO2) (R = 0.57 (CI 0.29–0.76), R = 0.59 (CI 0.31–0.77) and R = 0.62 (CI 0.35–0.79) respectively), anaerobic threshold (R = 0.37 (CI 0.01–0.64), R = 0.39 (CI 0.04–0.66) and R = 0.42 (CI 0.07–0.68) respectively) and peak work (R = 0.56 (CI 0.27–0.75), R = 0.48 (CI 0.17–0.70) and R = 0.50 (CI 0.2–0.72) respectively). Receiver operator curve (ROC) analysis for direct and self-reported measures of 7-day physical activity could accurately approximate the ventilatory equivalent for carbon dioxide (VE/VCO2) and the anaerobic threshold. The area under these curves was 0.89 for VE/VCO2 and 0.91 for the anaerobic threshold. For peak VO2 and peak work, models fitted using just the wearable data were 0.93 for peak VO2 and 1.00 for peak work. Conclusions Data recorded by the wearable device was able to consistently approximate CPET results, both with and without the addition of patient reported activity measures via IPAQ scores. This highlights the potential utility of wearable devices in formal assessment of physical functioning and suggests they could play a larger role in pre-operative risk assessment. Ethics This study entitled “uSing wearable TEchnology to Predict perioperative high-riSk patient outcomes (STEPS)” gained favourable ethical opinion on 24 January 2017 from the Welsh Research Ethics Committee 3 reference number 17/WA/0006. It was registered on ClinicalTrials.gov with identifier NCT03328039.


2009 ◽  
Vol 17 (9) ◽  
pp. 339-344 ◽  
Author(s):  
T. Takken ◽  
A. C. Blank ◽  
E. H. Hulzebos ◽  
M. van Brussel ◽  
W. G. Groen ◽  
...  

2014 ◽  
Vol 36 (2) ◽  
pp. 92-98
Author(s):  
Milena Pelosi Rizk Sperling ◽  
Flávia Cristina Rossi Caruso ◽  
Renata Gonçalves Mendes ◽  
Daniela Bassi Dutra ◽  
Vivian Maria Arakelian ◽  
...  

Author(s):  
Maria Simakova ◽  
Irina Zlobina ◽  
Aelita Berezina ◽  
Konstantin Pishchulov ◽  
Narek Marykyan ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document