scholarly journals IPPB and hypercapnia in respiratory failure: The effect of different concentrations of inspired oxygen on arterial blood gas tensions

Anaesthesia ◽  
1979 ◽  
Vol 34 (3) ◽  
pp. 283-287 ◽  
Author(s):  
I.D. Starke ◽  
B.A. Webber ◽  
M.A. Branthwaite
PEDIATRICS ◽  
1986 ◽  
Vol 78 (1) ◽  
pp. 139-143 ◽  
Author(s):  
Waldemar A. Carlo ◽  
Lucia Pacifico ◽  
Robert L. Chatburn ◽  
Avroy A. Fanaroff

We modified an algorithm for mechanical ventilation of infants with respiratory distress syndrome to create an interactive user-friendly computer program. To determine the effectiveness of this computer program, we evaluated the correction of deranged arterial blood gases in three groups of neonates: group I, treated before the introduction of the computer into the nursery; group II, managed by pediatric residents with the guidance of the computer program; group III, treated after the introduction of the computer into the nursery but managed without consideration of the computer output. Arterial blood gas values improved more frequently in the neonates managed with computer consultation (group II, 65/75, 87%) than in both control groups (group I, 37/57, 65%, P < .005; and group III, 46/63, 73%, P < .05). Furthermore, increases in ventilatory support in the presence of normal arterial blood gas values occurred only in patients managed without computer guidance. In a teaching institution, more effective care of neonates with respiratory failure may be facilitated by computer-assisted management of mechanical ventilators.


1986 ◽  
Vol 9 (6) ◽  
pp. 427-432 ◽  
Author(s):  
R. Fumagalli ◽  
T. Kolobow ◽  
P. Arosio ◽  
V. Chen ◽  
D.K. Buckhold ◽  
...  

A total of 44 preterm fetal lambs at great risk of developing respiratory failure were delivered by Cesarean section, and were then managed on conventional mechanical pulmonary ventilation. Fifteen animals initially fared well, and 14 of these were long term survivors. Twenty-nine other lambs showed a progressive deterioration in arterial blood gases within 30 minutes of delivery, of which 10 lambs were continued on mechanical pulmonary ventilation (20% survival), while the remaining 19 lambs were placed on an extracorporeal membrane lung respiratory assist (79% survival). Extracorporeal membrane lung bypass rapidly corrected arterial blood gas values, and permitted the use of high levels of CPAP instead of the continuation of mechanical pulmonary ventilation at high peak airway pressures. Improvement in lung function was gradual, and predictable. Early institution of extracorporeal respiratory assist using a membrane artificial lung rapidly corrected arterial blood gas values and significantly improved on neonate survival.


CNS Spectrums ◽  
2010 ◽  
Vol 15 (S8) ◽  
pp. 10-13 ◽  
Author(s):  
Peter J. Weiden ◽  
Michael Weiden

Mr. A is 24 years of age with a history of schizophrenia (Slide 1). He has been living with his parents and has been ill for a few years. Police saw him on the street in a state of crisis and brought him to the emergency room (ER). He was very anxious and his delusions of being in great physical danger had worsened. He reported a history of asthma, but it was noted that his asthma occurred a long time ago and was inactive; however, due to his anxiety, his smoking had increased to where it was continuous. At the time he was brought to the ER, Mr. A was triaged to psychiatry and became agitated in the waiting area; hence, security was called. He was about to be restrained and given an intramuscular dose (IM) of lorazepam, but the psychiatrist noted that he was having trouble breathing and stopped the IM before it was given. The psychiatrist noticed that Mr. A was wheezing, had a rapid respiratory rate of 25/minute, was tachycardic, and sweating. His pulse oximeter measurement was 90% saturated, which is considered low.Mr. A was re-interviewed and reported that he previously had asthma. His parents were contacted and agreed that he had active asthma, had stopped his psychiatric treatment several months ago, and, more recently, stopped his asthma medications when his prescriptions were not refilled ∼1 week prior to this episode. An emergency arterial blood gas showed a pH of acidosis at 7.27; a Po2 of 60 (normal is 80); and a Pco2 of 48 (normal is 40). The Pco2 was of particular concern because if he was retaining CO2, respiratory failure was imminent.


2013 ◽  
Vol 20 (1) ◽  
pp. e5-e9 ◽  
Author(s):  
Douglas A McKim ◽  
Nadia Griller ◽  
Carole LeBlanc ◽  
Andrew Woolnough ◽  
Judy King

BACKGROUND: Almost all patients with Duchenne muscular dystrophy (DMD) eventually develop respiratory failure. Once 24 h ventilation is required, either due to incomplete effectiveness of nocturnal noninvasive ventilation (NIV) or bulbar weakness, it is common practice to recommend invasive tracheostomy ventilation; however, noninvasive daytime mouthpiece ventilation (MPV) as an addition to nocturnal mask ventilation is also an alternative.METHODS: The authors’ experience with 12 DMD patients who used 24 h NIV with mask NIV at night and MPV during daytime hours is reported.RESULTS: The mean (± SD) age and vital capacity (VC) at initiation of nocturnal (only) NIV subjects were 17.8±3.5 years and 0.90±0.40 L (21% predicted), respectively; and, at the time of MPV, 19.8±3.4 years and 0.57 L (13.2% predicted), respectively. In clinical practice, carbon dioxide (CO2) levels were measured using different methods: arterial blood gas analysis, transcutaneous partial pressure of CO2and, predominantly, by end-tidal CO2. While the results suggested improved CO2levels, these were not frequently confirmed by arterial blood gas measurement. The mean survival on 24 h NIV has been 5.7 years (range 0.17 to 12 years). Of the 12 patients, two deaths occurred after 3.75 and four years, respectively, on MPV; the remaining patients continue on 24 h NIV (range two months to 12 years; mean 5.3 years; median 3.5 years).CONCLUSIONS: Twenty-four hour NIV should be considered a safe alternative for patients with DMD because its use may obviate the need for tracheostomy in patients with chronic respiratory failure requiring more than nocturnal ventilation alone.


2019 ◽  
pp. 102490791988624
Author(s):  
Mustafa Gedikloglu ◽  
Muge Gulen ◽  
Salim Satar ◽  
Yahya Kemal Icen ◽  
Akkan Avci ◽  
...  

Objective: To investigate whether high-flow nasal cannula oxygen therapy could reduce the rate of endotracheal intubation and improve arterial blood gas values, vital signs, and clinical outcomes of patients with hypoxemic acute respiratory failure as compared with conventional oxygen therapy alone. Methods: This retrospective, observational study was performed in the 15-month study period and included adult patients with tachypnea and hypoxemia, whose vital signs and arterial blood gas were monitored. The high-flow nasal cannula oxygen group consisted of patients admitted to the emergency department with acute respiratory failure when high-flow nasal cannula oxygen treatment was available in the hospital, while the conventional oxygen therapy group consisted of patients who have presented to the emergency department with acute respiratory failure in the absence of high-flow nasal cannula oxygen device in the hospital. The primary outcome of the study was improvement in vital signs and arterial blood gas values within first and fourth hours of the treatment. The second outcome was the need for intubation in the emergency department, length of hospital stay, and hospital mortality. Results: The decrease in the pulse and respiratory rate of high-flow nasal cannula oxygen–treated group was significantly greater than the conventional oxygen therapy group on the first and fourth hours of treatment (p < 0.001). PaO2 values were significantly higher in the high-flow nasal cannula oxygen group at the first and fourth hours of treatment (p ⩽ 0.001). Likewise, mean SaO2 levels of patients receiving high-flow nasal cannula oxygen treatment was significantly higher than those of patients in the conventional oxygen therapy group (p = 0.006 at 1 h and p < 0.001 at 4 h). In the hypercapnic patients, the decrease in PaCO2 and increase in pH and PaO2 values were significantly greater in high-flow nasal cannula oxygen group (p < 0.001). The difference between the groups regarding the need for invasive mechanical ventilation was not statistically significant (p = 0.179). Conclusion: High-flow nasal cannula oxygen treatment has been associated with favorable effects in vital signs and arterial blood gas values in patients with acute respiratory failure. High-flow nasal cannula oxygen might be considered as the first-line therapy for patients with hypoxemic and/or hypercapnic acute respiratory failure.


1980 ◽  
Vol 58 (1) ◽  
pp. 105-106 ◽  
Author(s):  
P. D'A. Semple ◽  
G. H. Beastall ◽  
W. S. Watson ◽  
R. Hume

1. We have measured serum testosterone and arterial blood gas values in men with chronic obstructive airways disease. 2. Depression of serum testosterone concentrations was found. 3. The degree of testosterone depression was related to the severity of arterial hypoxia.


Sign in / Sign up

Export Citation Format

Share Document