The influence of the position of surface recording electrodes on the relative uptake of the masseteric and temporal M-responses in man

1995 ◽  
Vol 103 (6) ◽  
pp. 345-350 ◽  
Author(s):  
Guido Maria Macaluso ◽  
Antoon Laat
Author(s):  
Robert P. Carlyon ◽  
François Guérit ◽  
John M. Deeks ◽  
Andrew Harland ◽  
Robin Gransier ◽  
...  

AbstractWe measured the sustained neural response to electrical stimulation by a cochlear implant (CI). To do so, we interleaved two stimuli with frequencies F1 and F2 Hz and recorded a neural distortion response (NDR) at F2-F1 Hz. We show that, because any one time point contains only the F1 or F2 stimulus, the instantaneous nonlinearities typical of electrical artefact should not produce distortion at this frequency. However, if the stimulus is smoothed, such as by charge integration at the nerve membrane, subsequent (neural) nonlinearities can produce a component at F2-F1 Hz. We stimulated a single CI electrode with interleaved sinusoids or interleaved amplitude-modulated pulse trains such that F2 = 1.5F1, and found no evidence for an NDR when F2-F1 was between 90 and 120 Hz. However, interleaved amplitude-modulated pulse trains with F2-F1~40 Hz revealed a substantial NDR with a group delay of about 45 ms, consistent with a thalamic and/or cortical response. The NDR could be measured even from recording electrodes adjacent to the implant and at the highest pulse rates (> 4000 pps) used clinically. We then measured the selectivity of this sustained response by presenting F1 and F2 to different electrodes and at different between-electrode distances. This revealed a broad tuning that, we argue, reflects the overlap between the excitation elicited by the two electrodes. Our results also provide a glimpse of the neural nonlinearity in the auditory system, unaffected by the biomechanical cochlear nonlinearities that accompany acoustic stimulation. Several potential clinical applications of our findings are discussed.


1991 ◽  
Vol 115 (4) ◽  
pp. 933-939 ◽  
Author(s):  
C M Feldherr ◽  
D Akin

Mediated transport across the nuclear envelope was investigated in proliferating and growth-arrested (confluent or serum starved) BALB/c 3T3 cells by analyzing the nuclear uptake of nucleoplasmin-coated colloidal gold after injection into the cytoplasm. Compared with proliferating cells the nuclear uptake of large gold particles (110-270 A in diameter, including the protein coat) decreased 5.5-, 33-, and 78-fold, respectively, in 10-, 14-17-, and 21-d-old confluent cultures; however, the relative uptake of small particles (total diameter 50-80 A) did not decrease with increasing age of the cells. This finding suggests that essentially all pores remain functional in confluent populations, but that most pores lose their capacity to transport large particles. By injecting intermediate-sized gold particles, the functional diameters of the transport channels in the downgraded pores were estimated to be approximately to 130 and 110 A, in 14-17- and 21-d-old cultures, respectively. In proliferating cells, the transport channels have a functional diameter of approximately 230 A. The mean diameters of the pores (membrane-to-membrane distance) in proliferating and confluent cells (728 and 712 A, respectively) were significantly different at the 10%, but not the 5%, level. No differences in pore density (pore per unit length of membrane) were detected. Serum-deprived cells (7-8 d in 1% serum or 4 d in 0.5% serum) also showed a significant decrease in the nuclear uptake of large, but not small, gold particles. Thus, the permeability effects are not simply a function of high cell density but appear to be growth related. The possible functional significance of these findings is discussed.


2002 ◽  
Vol 41 (04) ◽  
pp. 337-341 ◽  
Author(s):  
F. Cincotti ◽  
D. Mattia ◽  
C. Babiloni ◽  
F. Carducci ◽  
L. Bianchi ◽  
...  

Summary Objectives: In this paper, we explored the use of quadratic classifiers based on Mahalanobis distance to detect mental EEG patterns from a reduced set of scalp recording electrodes. Methods: Electrodes are placed in scalp centro-parietal zones (C3, P3, C4 and P4 positions of the international 10-20 system). A Mahalanobis distance classifier based on the use of full covariance matrix was used. Results: The quadratic classifier was able to detect EEG activity related to imagination of movement with an affordable accuracy (97% correct classification, on average) by using only C3 and C4 electrodes. Conclusions: Such a result is interesting for the use of Mahalanobis-based classifiers in the brain computer interface area.


2017 ◽  
Vol 5 (13) ◽  
pp. 2445-2458 ◽  
Author(s):  
I. Mitch Taylor ◽  
Zhanhong Du ◽  
Emma T. Bigelow ◽  
James R. Eles ◽  
Anthony R. Horner ◽  
...  

First everin vivosensor for directly measuring cocaine concentration in the brainviaelectrochemical detection at DNA aptamer functionalized single shank, silicon-based neural recording probes.


1977 ◽  
Vol 232 (2) ◽  
pp. E109
Author(s):  
S Yokoyama ◽  
T Ozaki ◽  
T Kajitsuka

Excitation conduction in Meissner's plexus of the rabit small intestine was investigated by analyzing the records of potentials evoked by a single electrical stimulus applied to this plexus. Experiments were performed on the Meissner's plexus that remained attached to the circular muscle after the longitudinal muscle and mucous membrane were removed from intestinal segment. Conduction velocities of nerve impulses were 0.3-0.7 m/s, chronaxie of the nerve bundle was 0.06-0.12 ms. While the distance between the stimulating and recording electrodes was increased, the latency of evoked potentials was prolonged, the number increased, and the amplitude decreased; no potentials could be recorded when the distance was more than 4 mm. Evoked potentials recorded at relatively long conduction distance were reduced in amplitude or abolished after a repeated stimulation with high frequencies above 50/s, after hexamethonium application, and in a state of lack of oxygen. It was concluded that, in Meissner's plexus, nerve impulses spread through multiple pathways and make synaptic transmission at a relatively short conduction distance.


2019 ◽  
Vol 122 (3) ◽  
pp. 975-983 ◽  
Author(s):  
Yonatan Katz ◽  
Michael Sokoletsky ◽  
Ilan Lampl

Deep brain nuclei, such as the amygdala, nucleus basalis, and locus coeruleus, play a crucial role in cognition and behavior. Nonetheless, acutely recording electrical activity from these structures in head-fixed awake rodents has been very challenging due to the fact that head-fixed preparations are not designed for stereotactic accuracy. We overcome this issue by designing the DeepTarget, a system for stereotactic head fixation and recording, which allows for accurately directing recording electrodes or other probes into any desired location in the brain. We then validated it by performing intracellular recordings from optogenetically tagged amygdalar neurons followed by histological reconstruction, which revealed that it is accurate and precise to within ~100 μm. Moreover, in another group of mice we were able to target both the mammillothalamic tract and subthalamic nucleus. This approach can be adapted to any type of extracellular electrode, fiber optic, or other probe in cases where high accuracy is needed in awake, head-fixed rodents. NEW & NOTEWORTHY Accurate targeting of recording electrodes in awake head-restrained rodents is currently beyond our reach. We developed a device for stereotactic implantation of a custom head bar and a recording system that together allow the accurate and precise targeting of any brain structure, including deep and small nuclei. We demonstrated this by performing histology and intracellular recordings in the amygdala of awake mice. The system enables the targeting of any probe to any location in the awake brain.


Author(s):  
Daryl R. Kipke ◽  
David S. Pellinen ◽  
Patrick J. Rousche
Keyword(s):  

1973 ◽  
Vol 55 (1) ◽  
pp. 197
Author(s):  
P. M. McIlvaine ◽  
G. Lengyel ◽  
V. H. Hutchison

Sign in / Sign up

Export Citation Format

Share Document