Outcomes of posterior wall isolation with pulmonary vein isolation for paroxysmal atrial fibrillation

Author(s):  
Lior Jankelson ◽  
Leonid Garber ◽  
Eric Shulman ◽  
Roi Bar Cohen ◽  
Connor Peterson ◽  
...  
EP Europace ◽  
2020 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
A P Martin ◽  
M Fowler ◽  
N Lever

Abstract Background Pulmonary vein isolation using cryotherapy is an established treatment for the management of patients with paroxysmal atrial fibrillation. Ablation using the commercially available balloon cryocatheter has been shown to create wide antral pulmonary vein isolation. A novel balloon cryocatheter (BCC) has been designed to maintain uniform pressure and size during ablation, potentially improving contact with the antral anatomy. The extent of ablation created using the novel BCC has not previously been established. Purpose To determine the anatomical extent of pulmonary vein isolation using electroanatomical mapping when performing catheter ablation for paroxysmal atrial fibrillation using the novel BCC. Methods Nine consecutive patients underwent pre-procedure computed tomography angiography of the left atrium to quantify the chamber dimensions. An electroanatomical map was created using the cryoablation system mapping catheter and a high definition mapping system. A bipolar voltage map was obtained following ablation to determine the extent of pulmonary vein isolation ablation. A volumetric technique was used to quantify the extent of vein and posterior wall electrical isolation in addition to traditional techniques for proving entrance and exit block. Results All patients had paroxysmal atrial fibrillation, mean age 56 years, 7 (78%) male. Electrical isolation was achieved for 100% of the pulmonary veins; mean total procedure time was 109 min (+/- 26 SD), and fluoroscopy time 14.9 min (+/- 2.4 SD). The median treatment applications per vein was one (range one - four), and median treatment duration 180 sec (range 180 -240). Left atrial volume 32 mL/m2 (+/- 7 SD), and mean left atrial posterior wall area 22 cm2 (+/- 4 SD). Data was available for quantitative assessment of the extent of ablation for eight patients. No lesions (0 of 32) were ostial in nature. The antral surface area of ablation was not statistically different between the left and right sided pulmonary veins (p 0.63), which were 5.9 (1.6 SD) and 5.4 (2.1 SD) cm2 respectively. In total 50% of the posterior left atrial wall was ablated.  Conclusion Pulmonary vein isolation using a novel BCC provides a wide and antral lesion set. There is significant debulking of the posterior wall of the left atrium. Abstract Figure.


2020 ◽  
Vol 33 (2) ◽  
pp. 82-88
Author(s):  
Tolga Aksu ◽  
Tumer Erdem Guler ◽  
Serdar Bozyel ◽  
Kivanc Yalin

Although pulmonary vein isolation (PVI) remains the cornerstone of ablation for paroxysmal atrial fibrillation (AF), optimal ablation strategy for long-standing persistent AF (LSPAF) remains unclear. This article presents two patients with LSPAF in whom acute AF termination was achieved during ablation by using fractionated-guided extended PVI, posterior wall isolation, and mitral isthmus.


Heart Rhythm ◽  
2021 ◽  
Vol 18 (8) ◽  
pp. S127-S128
Author(s):  
Leonid Garber ◽  
Lior Jankelson ◽  
Eric H. Shulman ◽  
Roi Bar-Cohen ◽  
Connor Peterson ◽  
...  

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
A Chikata ◽  
T Kato ◽  
K Ududa ◽  
S Fujita ◽  
K Otowa ◽  
...  

Abstract Introduction Pulmonary vein isolation (PVI) affects ganglionated plexi (GP) around the atrium, leading to a modification of the intrinsic cardiac autonomic system (ANS). In animal models, GP ablation has a potential risk of QT prolongation and ventricular arrhythmias. However, the impact of PVI on QT intervals in humans remains unclear. Purpose This study aims to evaluate the Impact of PVI on QT interval in patients with paroxysmal atrial fibrillation. Methods We analyzed consecutive 117 PAF patients for their first PVI procedures. 12-lead ECG was evaluated at baseline, 4 hr, day 1, 1 month, and 3 months after ablation. Only patients with sinus rhythm on 12-lead ECG at each evaluation point without antiarrhythmic drugs were included. Results Heart rate significantly increased at 4 hr, day 1, and 1 month. Raw QT interval prolonged at 4 hr (417.1±41.6 ms, P<0.001) but shortened at day 1 (376.4±34.1 ms, P<0.001), 1 month (382.2±31.5 ms, P<0.001), and 3 months (385.1±32.8 ms, P<0.001) compared to baseline (391.6±31.4 ms). Bazett- and Fridericia- corrected QTc intervals significantly prolonged at 4hr (Bazett: 430.8±27.9 ms, P<0.001; Fridericia: 425.8±27.4 ms, P<0.001), day1 (Bazett: 434.8±22.3 ms, P<0.001; Fridericia: 414.1±23.7 ms, P<0.001), 1M (Bazett: 434.8±22.3 ms, P<0.001; Fridericia: 408.2±21.0 ms, P<0.05), and 3M (Bazett: 420.1±21.8 ms, P<0.001; Fridericia: 407.8±21.1 ms, P<0.05) compared to baseline (Bazett: 404.9±25.2 ms; Fridericia: 400.0±22.6 ms). On the other hand, Framingham- and Hodges- corrected QTc interval significantly prolonged only at 4hr (Framingham: 424.1±26.6 ms, P<0.001; Hodges: 426.8±28.4 ms, P<0.001) and at day1 (Framingham: 412.3±29.3 ms, P<0.01; Hodges: 410.6±40.2 ms, P<0.05) compared to baseline (Framingham: 399.2±22.7 ms; Hodges: 400.7±22.8 ms). At 4 hr after ablation, raw QT and QTc of all formulas significantly prolonged than baseline. Raw QT and QTc prolongation at 4hr after ablation were more frequently observed in female patients. Multiple regression analysis revealed that female patient is a significant predictor of raw QT and QTc interval prolongation of all formulas 4hr after PVI. Conclusions Raw QT and QTc prolonged after PVI, especially in the acute phase. Female patient is a risk factor for QT prolongation in the acute phase after PVI. Funding Acknowledgement Type of funding source: None


EP Europace ◽  
2020 ◽  
Author(s):  
Michelle Lycke ◽  
Maria Kyriakopoulou ◽  
Milad El Haddad ◽  
Jean-Yves Wielandts ◽  
Gabriela Hilfiker ◽  
...  

Abstract Aims Catheter ablation of paroxysmal atrial fibrillation (AF) reduces AF recurrence, AF burden, and improves quality of life. Data on clinical and procedural predictors of arrhythmia recurrence are scarce and are flawed by the high rate of pulmonary vein reconnection evidenced during repeat procedures after pulmonary vein isolation (PVI). In this study, we identified clinical and procedural predictors for AF recurrence 1 year after CLOSE-guided PVI, as this strategy has been associated with an increased PVI durability. Methods and results Patients with paroxysmal AF, who received CLOSE-guided PVI and who participated in a prospective trial in our centre, were included in this study. Uni- and multivariate models were plotted to find clinical and procedural predictors for AF recurrence within 1 year. Three hundred twenty-five patients with a mean age of 63 years (CHA2DS2VASc 1 [1–3], left atrium diameter 41 ± 6 mm) were included. About 60.9% were male individuals. After 1 year, AF recurrence occurred in 10.5% of patients. In a binary logistic regression analysis, the diagnosis-to-ablation time (DAT) was found to be the strongest predictor of AF recurrence (P = 0.011). Diagnosis-to-ablation time ≥1 year was associated with a nearly two-fold increased risk for developing AF recurrence. Conclusion The DAT is the most important predictor of arrhythmia recurrence in low-risk patients treated with durable pulmonary vein isolation for paroxysmal AF. Whether reducing the DAT could improve long-term outcomes should be investigated in another trial.


Sign in / Sign up

Export Citation Format

Share Document