scholarly journals Discussion: “Criteria for Spike Initiated Rotating Stall” (Vo, H. D., Tan, C. S., Greitzer, E. M., 2008, ASME J. Turbomach., 130, p. 011023)

2008 ◽  
Vol 130 (1) ◽  
Author(s):  
A. Deppe ◽  
H. Saathoff ◽  
U. Stark

The paper “Criteria for Spike Initiated Rotating Stall” by Vo et al. (2008, ASME J. Turbomach., 130, p. 011023) provides a very important contribution to the understanding of spike-type stall inception in axial-flow compressors by demonstrating that spike-type disturbances are directly linked to the tip leakage flow of the rotor. The computational study of Vo et al. leads to the conclusion that two conditions have to be fulfilled simultaneously for the formation of spike-type stall: (i) axial backflow at the leading edge plane and (ii) axial backflow at the trailing edge plane. The objective of the present technical brief is to support these findings by corresponding experimental results.

Author(s):  
Xiaochen Mao ◽  
Bo Liu

Unsteady computations of a counter-rotating axial compressor are performed and analyzed to investigate the unsteady behaviors in the compressor and the role of the tip leakage flow together with the rotating stall inception process. The results show that the oscillation on the pressure side is much stronger than that on the suction surface for both rotors, especially near the tip region where the trajectory of the tip leakage vortex (TLV) interacts with the blades most often. There exists a periodical leading edge spillage of the interface in rotor2 due to the unsteadiness of tip leakage flow (TLF) at near-stall condition. The blockage generated by the TLV increases dramatically due to the increasing strength of the TLV and the backflow phenomenon as the mass flow decreased. The appearance of the frequency components of 0.5 blade passing frequency (BPF) and 1.5BPF from 0.64BPF can be viewed as the rotating stall inception warning. The fluctuation strength of oscillation frequencies of 0.5BPF and 1.5BPF decreases rapidly from leading edge to trailing edge in rotor2, which indicates that the unsteady fluctuation of TLF at the leading edge in rotor2 is responsible for the stall inception of the compressor. Additionally, both the leading edge spillage and trailing edge backflow phenomena are observed for spike initiated rotating stall at stall point.


Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4168
Author(s):  
Botao Zhang ◽  
Xiaochen Mao ◽  
Xiaoxiong Wu ◽  
Bo Liu

To explain the effect of tip leakage flow on the performance of an axial-flow transonic compressor, the compressors with different rotor tip clearances were studied numerically. The results show that as the rotor tip clearance increases, the leakage flow intensity is increased, the shock wave position is moved backward, and the interaction between the tip leakage vortex and shock wave is intensified, while that between the boundary layer and shock wave is weakened. Most of all, the stall mechanisms of the compressors with varying rotor tip clearances are different. The clearance leakage flow is the main cause of the rotating stall under large rotor tip clearance. However, the stall form for the compressor with half of the designed tip clearance is caused by the joint action of the rotor tip stall caused by the leakage flow spillage at the blade leading edge and the whole blade span stall caused by the separation of the boundary layer of the rotor and the stator passage. Within the investigated varied range, when the rotor tip clearance size is half of the design, the compressor performance is improved best, and the peak efficiency and stall margin are increased by 0.2% and 3.5%, respectively.


Author(s):  
Takahiro Nishioka ◽  
Toshio Kanno ◽  
Hiroshi Hayami

The flow mechanisms for spike and modal stall inceptions in a low-speed axial-flow fan with a relatively large tip clearance were studied. The pressure and velocity fluctuations were measured to clarify the influences of blade loading, end-wall flow, and tip-leakage flow on stall inception at two stagger-angle settings for the rotor blade, which are the design and small stagger-angle settings. A rotating instability was observed near the maximum pressure-rise point at both design and small stagger-angle settings. This instability was induced by the interaction between the incoming flow, tip-leakage flow, and end-wall backflow. The stall inception patterns were a spike type at the design stagger-angle setting and a modal type at the small stagger-angle setting. At the design stagger-angle setting, the interface between the incoming flow, tip-leakage flow, and end-wall backflow became parallel to the rotor leading edge plane and reached the pressure side of adjacent blade. The interaction between these flows generated the large end-wall blockage in the rotor blade passage, and this blockage developed leading edge separation on the overloaded rotor blade at the tip. The leading edge separation that developed then grew into a spike, which traveled upstream of the rotor. At the small stagger-angle setting, the rotating instability and modal disturbance were also induced by the interaction between the incoming flow, tip-leakage flow, and end-wall backflow. However, the interface between the tip-leakage flow and end-wall backflow surrounded the suction surface of the rotor blade at the tip and neither became parallel to the leading edge plane nor reached the pressure side of the adjacent blade even though the rotor blade at the tip had stalled. Spikes did not therefore appear. The modal disturbance periodically decreased the inlet velocity and induced a long length-scale stall cell including a spike. It is concluded from these results that the stall inception patterns, which were characterized by the interaction between the incoming flow, tip-leakage flow, and end-wall backflow, depended on the stagger-angle settings for the rotor blades.


Author(s):  
Takahiro Nishioka ◽  
Toshio Kanno ◽  
Hiroshi Hayami

End wall flow fields at the two stagger-angle settings for the rotor blades in the low-speed axial-flow fan are experimentally and numerically investigated to elucidate the mechanism of stall inception. Rotating instability is confirmed near the maximum pressure-rise point at both design and large stagger-angle settings. This instability is induced by the interaction between the incoming flow, tip leakage flow, and backflow from the trailing edge. The stall-inception pattern, however, differs at the two stagger-angle settings. The stall inception from a spike is observed at the design stagger-angle setting, and the stall inception without the spike and modal disturbance is observed at the large stagger-angle setting. The rotating instability seems to influence the formation of stall cell at the large stagger-angle setting. Tip-leakage vortex breakdown occurs at both design and large stagger angle settings. This breakdown induces the three-dimensional separation on the suction surface of the rotor blade at the tip. Three-dimensional separation at the design stagger-angle setting is stronger than that at the large stagger-angle setting. The strong separation grows into a three-dimensional separation vortex, which crosses the blade passage near the trailing edge. This separation vortex seems to be one of the conditions for spike initiation.


Author(s):  
Takahiro Nishioka ◽  
Toshio Kanno ◽  
Hiroshi Hayami

The rotor-tip flow fields in two rotors of a low-speed axial-flow fan were experimentally and numerically investigated to clarify the mechanism behind modal stall inception. A NACA 65 wing section and a controlled diffusion airfoil were applied to the two rotors. At the small stagger-angle setting for both rotors, which is ten degrees smaller than the design value, the modal disturbance is observed near the peak pressure-rise point, and the rotor blades at the tip stall before the modal disturbance is observed. In the modal stall inception, the interface between the incoming flow and the reversed tip-leakage flow does not become parallel to the leading edge plane, although backflow from the trailing edge initiates near the stall condition. The reversed tip-leakage flow does not spill from the leading edge at the stall condition. Moreover, the tip-leakage vortex breakdown does not occur near or at the stall condition. A three-dimensional separation vortex is induced by secondary flow on the suction surface near the stall condition and develops at the stall condition. It is concluded from these results that the rotor-tip flow fields in the modal stall inception differ from those in the spike stall inception and that the three-dimensional separation vortex induced by the secondary flow influences the initiation of modal disturbance.


Author(s):  
Wei Wang ◽  
Wuli Chu ◽  
Haoguang Zhang ◽  
Yanhui Wu

Recirculating casing treatment (RCT) was studied in a subsonic axial flow compressor experimentally and numerically. The RCT was parameterized with the injector throat height and circumferential coverage percentage (ccp) to investigate its influence on compressor stability and on the overall performance in the experimentation. The injector throat height varied from 2 to 6 times the height of the rotor tip clearance, and the ccp ranged from 8.3% to 25% of the casing perimeter. Various RCT configurations were achieved with a modular design procedure. The rotor casing was instrumented with fast-response pressure transducers to detect the stall inception, rotational speed of stall cells, and pressure flow fields. Whole-passage unsteady simulations were also implemented for the RCT and solid casing to understand the flow details. Results indicate that both the compressor stability and overall performance can be improved through RCT with appropriate geometrical parameters. The effect of injector throat height on the stability depends on the choice of ccp, i.e., interaction effect exists. In general, the RCT with a moderate injector throat height and a large circumferential coverage is the optimal choice. Phase-locked pattern of the casing wall pressure reveals a weakened tip leakage vortex under the effect of RCT compared with the solid casing. The numerical results show that the RCT has a substantial effect on tip blockage even when the blade passages break away from the domain of RCT. The reduction of tip blockage induced by the tip leakage vortex is the main reason for the extension of stable operation range. The unsteadiness of double-leakage flow is detected both in the experiment and in numerical simulations. The pressure fluctuations caused by double-leakage flow are depressed with RCT. This observation indicates reduced losses related with the double-leakage flow. Although the stall inception is not changed by implementing RCT, the stall pattern is altered. The stall with two cells is detected in RCT compared with the solid casing with only one stall cell.


Author(s):  
Xiaochen Mao ◽  
Bo Liu ◽  
Hang Zhao

This paper presents the studies performed to better understand the effects of increased tip clearance size on the unsteady flow behaviors and overall performance under the rotor–rotor interaction environment in a counter-rotating axial flow compressor. The investigation method is based on the three-dimensional unsteady Reynolds-averaged Navier–Stokes simulations. The results show that the intensified tip leakage flow in front rotor (R1) caused by the increased tip clearance size will lead to the growth of incoming incidence angle near the tip of the rear rotor (R2). The increasing of double leakage flow range plays a significant role in the sensitivity of the efficiency to tip clearance size and its extent is enlarged gradually with the increase of tip clearance size. As the tip clearance size is increased to 1.5τ (τ represents the designed tip clearance size) from 0.5τ, the results of the fast Fourier transform for the static pressure near blade tip show that two other new fluctuating frequency components appear due to the happening of tip leakage flow self-unsteadiness in R1 and R2, respectively. Additionally, the fluctuating strength near the tip in R2 is significantly increased. However, both the overall fluctuation in R1 caused by the potential effect from downstream and the oscillation in the hub corner on the pressure side of R2 are decreased obviously. The relative inflow angle tends to increase when the incoming wakes and tip leakage flow from R1 encounter the blade leading edge of R2, which leads to the result that the trajectory of tip leakage flow is shifted more upstream.


Author(s):  
Limin Gao ◽  
Ruiyu Li ◽  
Fang Miao ◽  
Yutong Cai

Contra-rotating axial compressor/fan (CRAC) is a promising technology to meet the future goals aircraft industry. Massive time accurate simulations are performed to investigate rotating stall in CRAC containing two counter-rotating rotors. Particularly, the back pressure increasing with a very small step to avoid missing flow field transition from stability to instability. Due to the canceling of the stator, the instability of downstream rotor is more stronger. The present studies mostly focus on the downstream rotor. The tip leakage flow field is analyzed in detail under near stall condition, which indicates that a secondary leakage flow plays an important role in the unsteadiness of CRAC's unsteady flow field. The frequency analysis in the tip clearance of downstream rotor under multiple near stall conditions captured the transition of the second harmonic frequency which can be used as stall inception signal. Moreover, the rotating stall onset process in real CRAC is simulated on the numerical stall.


2020 ◽  
Vol 37 (1) ◽  
pp. 1-16 ◽  
Author(s):  
Bin Jiang ◽  
Xiangtong Shi ◽  
Qun Zheng ◽  
Qingfang Zhu ◽  
Zhongliang Chen ◽  
...  

AbstractThe onset of spike stall induced by the interaction of hub corner separation flow with the tip leakage flow is investigated in detail by numerical method in this paper. The time resolved results indicate that the remarkable radial secondary flow from hub to tip near the trailing edge is formed when the compressor approaching rotating stall. The radial secondary flow is unstable and cross-passages propagates, which flows in and away out of the tip region periodically. The disturbance caused by radial secondary flow will influence the tip leakage flow directly by reforming the vortexes in blade tip region. A secondary vortex which comes from the radial migration of corner separation and is induced by the tip leakage vortex appears in the tip region. The simulation result demonstrates that the generation of the secondary vortex is an important symbol of blockage growth in the tip region at the stall inception phase. The disturbance produced by secondary vortex is an incentive of the leading edge overflow and the intensity of secondary vortex could be used as a criterion of rotating stall before leading edge spillage.


Sign in / Sign up

Export Citation Format

Share Document