Film-Cooling Effectiveness Downstream of a Single Row of Holes With Variable Density Ratio

1991 ◽  
Vol 113 (3) ◽  
pp. 442-449 ◽  
Author(s):  
A. K. Sinha ◽  
D. G. Bogard ◽  
M. E. Crawford

Film-cooling effectiveness was studied using a row of inclined holes that injected cryogenically cooled air across a flat, adiabatic test plate. The density ratio of the coolant to mainstream varied from 1.2 to 2.0. Surface temperatures were measured using a unique surface thermocouple arrangement free of conduction errors. Temperatures were obtained along the jet centerline and across a number of lateral locations. By independently varying density ratio and blowing rate, scaling of adiabatic effectiveness with mass flux ratio, velocity ratio, and momentum ratio was determined. Depending on the momentum flux ratio, the jet either remains attached to the surface, detaches and then reattaches, or is fully detached. For attached jets, the centerline effectiveness scaled with the mass flux ratio. However, for detached-reattached jets, a consistent scaling was not found although the general distribution of the centerline effectiveness scaled with momentum flux ratio. Laterally averaged effectiveness was found to be dependent on density ratio and momentum flux ratio. Decreases in density ratio and increases in momentum flux ratio were found to reduce the spreading of the film cooling jet significantly and thereby reduce laterally averaged effectiveness.

Author(s):  
Kevin Liu ◽  
Shang-Feng Yang ◽  
Je-Chin Han

Adiabatic film-cooling effectiveness is examined systematically on a typical high pressure turbine blade by varying three critical flow parameters: coolant blowing ratio, coolant-to-mainstream density ratio, and freestream turbulence intensity. Three average coolant blowing ratios 1.0, 1.5, and 2.0; three coolant density ratios 1.0, 1.5, and 2.0; two turbulence intensities 4.2% and 10.5%, are chosen for this study. Conduction-free pressure sensitive paint (PSP) technique is used to measure film-cooling effectiveness. Three foreign gases — N2 for low density, CO2 for medium density, and a mixture of SF6 and Argon for high density are selected to study the effect of coolant density. The test blade features 45° compound-angle shaped holes on the suction side and pressure side, and 3 rows of 30° radial-angle cylindrical holes around the leading edge region. The inlet and the exit Mach number are 0.27 and 0.44, respectively. Reynolds number based on the exit velocity and blade axial chord length is 750,000. Results reveal that the PSP is a powerful technique capable of producing clear and detailed film effectiveness contours with diverse foreign gases. As blowing ratio exceeds the optimum value, it induces more mixing of coolant and mainstream. Thus film-cooling effectiveness reduces. Greater coolant-to-mainstream density ratio results in lower coolant-to-mainstream momentum and prevents coolant to lift-off; as a result, film-cooling increases. Higher freestream turbulence causes effectiveness to drop everywhere except in the region downstream of suction side. Results are also correlated with momentum flux ratio and compared with previous studies. It shows that compound shaped hole has the greatest optimum momentum flux ratio, and then followed by axial shaped hole, compound cylindrical hole, and axial cylindrical hole.


Author(s):  
Donald L. Schmidt ◽  
Basav Sen ◽  
David G. Bogard

Film cooling effectiveness was studied experimentally in a flat plate test facility with zero pressure gradient using a single row of inclined holes which injected high density, cryogenically cooled air. Round holes and holes with a diffusing expanded exit were directed laterally away from the freestream direction with a compound angle of 60°. Comparisons were made with a baseline case of round holes aligned with the freestream. The effects of doubling the hole spacing to six hole diameters for each geometry were also examined. Experiments were performed at a density ratio of 1.6 with a range of blowing ratios from 0.5 to 2.5 and momentum flux ratios from 0.16 to 3.9. Lateral distributions of adiabatic effectiveness results were determined at streamwise distances from 3 D to 15 D downstream of the injection holes. All hole geometries had similar maximum spatially averaged effectiveness at a low momentum flux ratio of I = 0.25, but the round and expanded exit holes with compound angle had significantly greater effectiveness at larger momentum flux ratios. The compound angle holes with expanded exits had a much improved lateral distribution of coolant near the hole for all momentum flux ratios.


Author(s):  
Lingyu Zeng ◽  
Xueying Li ◽  
Jing Ren ◽  
Hongde Jiang

Most experiments of blade film cooling are conducted with density ratio lower than that of turbine conditions. In order to accurately model the performance of film cooling under a high density ratio, choosing an appropriate coolant to mainstream scaling parameter is necessary. The effect of density ratio on film cooling effectiveness on the surface of a gas turbine twisted blade is investigated from a numerical point of view. One row of film holes are arranged in the pressure side and two rows in the suction side. All the film holes are cylindrical holes with a pitch to diameter ratio P/d = 8.4. The inclined angle is 30°on the pressure side and 34° on the suction side. The steady solutions are obtained by solving Reynolds-Averaged-Navier-Stokes equations with a finite volume method. The SST turbulence model coupled with γ-θ transition model is applied for the present simulations. A film cooling experiment of a turbine vane was done to validate the turbulence model. Four different density ratios (DR) from 0.97 to 2.5 are studied. To independently vary the blowing ratio (M), momentum flux ratio (I) and velocity ratio (VR) of the coolant to the mainstream, seven conditions (M varying from 0.25 to 1.6 on the pressure side and from 0.25 to 1.4 on the suction side) are simulated for each density ratio. The results indicate that the adiabatic effectiveness increases with the increase of density ratio for a certain blowing ratio or a certain momentum flux ratio. Both on the pressure side and suction side, none of the three parameters listed above can serve as a scaling parameter independent of density ratio in the full range. The velocity ratio provides a relative better collapse of the adiabatic effectiveness than M and I for larger VRs. A new parameter describing the performance of film cooling is introduced. The new parameter is found to be scaled with VR for nearly the whole range.


2020 ◽  
Vol 142 (4) ◽  
Author(s):  
Francesco Ornano ◽  
Thomas Povey

Abstract The desire to improve gas turbines has led to a significant body of research concerning film cooling optimization. The open literature contains many studies considering the impact on film cooling performance of both geometrical factors (hole shape, hole separation, hole inclination, row separation, etc.) and physical influences (effect of density ratio (DR), momentum flux ratio, etc.). Film cooling performance (typically film effectiveness, under either adiabatic or diabatic conditions) is almost universally presented as a function of one or more of three commonly used non-dimensional groups: blowing—or local mass flux—ratio, density ratio, and momentum flux ratio. Despite the abundance of papers in this field, there is some confusion in the literature about the best way of presenting such data. Indeed, the very existence of a discussion on this topic points to lack of clarity. In fact, the three non-dimensional groups in common use (blowing ratio (BR), density ratio, and momentum flux ratio) are not entirely independent of each other making aspects of this discussion rather meaningless, and there is at least one further independent group of significance that is rarely discussed in the literature (specific heat capacity flux ratio). The purpose of this paper is to bring clarity to this issue of correct scaling of film cooling data. We show that the film effectiveness is a function of 11 (additional) non-dimensional groups. Of these, seven can be regarded as boundary conditions for the main flow path and should be matched where complete similarity is required. The remaining four non-dimensional groups relate specifically to the introduction of film cooling. These can be cast in numerous ways, but we show that the following forms allow clear physical interpretation: the momentum flux ratio, the blowing ratio, the temperature ratio (TR), and the heat capacity flux ratio. Two of these parameters are in common use, a third is rarely discussed, and the fourth is not discussed in the literature. To understand the physical mechanisms that lead to each of these groups being independently important for scaling, we isolate the contribution of each to the overall thermal field with a parametric numerical study using 3D Reynolds-averaged Navier–Stokes (RANS) and large eddy simulations (LES). The results and physical interpretation are discussed.


Author(s):  
S. Neelakantan ◽  
M. E. Crawford

The distributed Yavuzkurt injection model is extended to predict the effectiveness and heat transfer coefficients for film cooling injection from a single row of holes, aligned both along the direction of the freestream and at an angle with it. The injection angles were 24° and 35°. The compound angles considered were 50.5° and 60°. The Yavuzkurt film cooling model is used in conjunction with a one-equation model to yield the effectiveness and heat transfer predictions. The density ratios considered were 1.6 and 0.95 for the effectiveness predictions and 1.0 and 0.95 for the heat transfer predictions. For the effectiveness predictions, the blowing ratios range from 0.5 to 2.5, and the momentum flux ratios from 0.16 until 3.9. The hole spacings were 3, 6, and 7.8 hole diameters. The Yavuzkurt model constants are seen to be definitely correlated with the momentum flux ratio. Correlations for the model constants are obtained in terms of the momentum flux ratio. For the heat transfer predictions, the blowing ratios ranged from 0.4 to 2.0, and the momentum flux ratios from 0.16 to 3.9. The spacing between the holes was 3, 6, and 7.8 hole diameters. The matching between the effectiveness correlations and the heat transfer predictions is done on the basis of the momentum flux ratio. Results indicate that the Yavuzkurt model predictions are best for the in-line round holes. Heat transfer predictions are close to the experimental results for lower blowing ratios, until the ratio exceeds 1. For higher blowing ratios, the predictions, though less accurate, follow the experimental trends.


2016 ◽  
Vol 139 (2) ◽  
Author(s):  
James L. Rutledge ◽  
Marc D. Polanka ◽  
Nathan J. Greiner

The hostile turbine environment requires testing film cooling designs in wind tunnels that allow for appropriate instrumentation and optical access, but at temperatures much lower than in the hot section of an engine. Low-temperature experimental techniques may involve methods to elevate the coolant to freestream density ratio to match or approximately match engine conditions. These methods include the use of CO2 or cold air for the coolant while room temperature air is used for the freestream. However, the density is not the only fluid property to differ between typical wind tunnel experiments so uncertainty remains regarding which of these methods best provide scaled film cooling performance. Furthermore, matching of both the freestream and coolant Reynolds numbers is generally impossible when either mass flux ratio or momentum flux ratio is matched. A computational simulation of a film cooled leading edge geometry at high-temperature engine conditions was conducted to establish a baseline condition to be matched at simulated low-temperature experimental conditions with a 10× scale model. Matching was performed with three common coolants used in low-temperature film cooling experiments—room temperature air, CO2, and cold air. Results indicate that matched momentum flux ratio is the most appropriate for approximating adiabatic effectiveness for the case of room temperature air coolant, but matching the density ratio through either CO2 or cold coolant also has utility. Cold air was particularly beneficial, surpassing the ability of CO2 to match adiabatic effectiveness at the engine condition, even when CO2 perfectly matches the density ratio.


Author(s):  
Scott Lewis ◽  
Brett Barker ◽  
Jeffrey P. Bons ◽  
Weiguo Ai ◽  
Thomas H. Fletcher

Experiments were conducted to determine the impact of synfuel deposits on film cooling effectiveness and heat transfer. Scaled up models were made of synfuel deposits formed on film-cooled turbine blade coupons exposed to accelerated deposition. Three distinct deposition patterns were modeled: a large deposition pattern (max deposit peak ≅ 2 hole diameters) located exclusively upstream of the holes, a large deposition pattern (max deposit peak ≅ 1.25 hole diameters) extending downstream between the cooling holes, and a small deposition pattern (max deposit peak ≅ 0.75 hole diameter) also extending downstream between the cooling holes. The models featured cylindrical holes inclined at 30 degrees to the surface and aligned with the primary flow direction. The spacing of the holes were 3, 3.35, and 4.5 hole diameters respectively. Flat models with the same film cooling hole geometry and spacing were used for comparison. The models were tested using blowing ratios of 0.5–2 with a turbulent approach boundary layer and 0.5% freestream turbulence. The density ratio was approximately 1.1 and the primary flow Reynolds number at the film cooling row location was 300,000. An infrared camera was used to obtain the film cooling effectiveness from steady state tests and surface convective heat transfer coefficients using transient tests. The model with upstream deposition caused the primary flow to lift off the surface over the roughness peaks and allowed the coolant to stay attached to the model. Increasing the blowing ratio from 0.5 to 2 only expanded the region that the coolant could reach and improved the cooling effectiveness. Though the heat transfer coefficient also increased at high blowing ratios, the net heat flux ratio was still less than unity, indicating film cooling benefit. For the two models with deposition between the cooling holes, the free stream air was forced into the valleys in line with the coolant holes and degraded area-averaged coolant performance at lower blowing ratios. It is concluded that the film cooling effectiveness is highest when deposition is limited to upstream of the cooling holes. When accounting for the insulating effect of the deposits between the film holes, even the panels with deposits downstream of the film holes can yield a net decrease in heat flux for some cases.


2018 ◽  
Vol 0 (0) ◽  
Author(s):  
Mukesh Prakash Mishra ◽  
A K Sahani ◽  
Sunil Chandel ◽  
R K Mishra

Abstract Characteristics of full coverage film cooling of an adiabatic flat plate are studied for opposite injection of coolant at different angles. Two in-line adjacent rows of cooling holes injecting in opposite directions are considered in this study. The cooling performance is compared with the configurations having forward and reverse injecting holes at similar injection angles. The holes are arranged in an array of 20 rows with equal spacing both span-wise and stream-wise. Computational analyses are carried out over a wide range of velocity ratios (VR) of practical importance ranging from 0.5 to 2.0 at density ratio of about 1.0. Injection angle and velocity ratio are found to have strong influence on film cooling effectiveness of opposite injection. At low velocity ratio of VR=0.5, film cooling performance of opposite injection at 45° is found better than at other angles, i. e. 30° and 60°. At higher velocity ratios, injection at 30° is found superior. Film cooling effectiveness becomes insensitive to velocity ratios at higher range for 45° and 60° injections. Evolution of effusion film layer and interaction between coolant and primary flow is also studied in this paper.


1996 ◽  
Vol 118 (4) ◽  
pp. 807-813 ◽  
Author(s):  
D. L. Schmidt ◽  
B. Sen ◽  
D. G. Bogard

Film cooling effectiveness was studied experimentally in a flat plate test facility with zero pressure gradient using a single row of inclined holes, which injected high-density, cryogenically cooled air. Round holes and holes with a diffusing expanded exit were directed laterally away from the free-stream direction with a compound angle of 60 deg. Comparisons were made with a baseline case of round holes aligned with the free stream. The effects of doubling the hole spacing to six hole diameters for each geometry were also examined. Experiments were performed at a density ratio of 1.6 with a range of blowing ratios from 0.5 to 2.5 and momentum flux ratios from 0.16 to 3.9. Lateral distributions of adiabatic effectiveness results were determined at streamwise distances from 3 D to 15 D downstream of the injection holes. All hole geometries had similar maximum spatially averaged effectiveness at a low momentum flux ratio of I = 0.25, but the round and expanded exit holes with compound angle had significantly greater effectiveness at larger momentum flux ratios. The compound angle holes with expanded exits had a much improved lateral distribution of coolant near the hole for all momentum flux ratios.


1985 ◽  
Vol 107 (2) ◽  
pp. 313-320 ◽  
Author(s):  
P. M. Ligrani ◽  
C. Camci

A variable property correction is given for turbulent boundary layers that are film-cooled using staggered rows of injection holes inclined at 35 deg. With the correction, a relation is provided between the adiabatic film cooling effectiveness for constant property flow and heat transfer coefficients for variable property flow, which are based on the difference between the freestream recovery temperature and wall temperature. The variable property correction was determined from heat transfer measurements for a range of injection parameters at different values of the nondimensional coolant temperature and from results in the literature. Because the flow is compressible, the importance of the injection mass flux ratio, momentum flux ratio, and velocity ratio are considered in the determination of effectiveness.