Prediction of Flow-Induced Vibrations in Tubular Heat Exchangers—Part II: Experimental Investigation

2008 ◽  
Vol 131 (1) ◽  
Author(s):  
S. A. Al-Kaabi ◽  
Y. A. Khulief ◽  
S. A. Said

It has become evident that the modeling of the complex dynamics of fluidelastic forces that give rise to vibrations of tube bundles requires a great deal of experimental insight. Accordingly, the prediction of the flow-induced vibration due to unsteady cross-flow can be greatly aided by semi-analytical models, in which some coefficients are determined experimentally. A laboratory test rig with an instrumented test bundle is constructed to measure the fluidelastic coefficients to be used in conjunction with the mathematical model derived in Part I of this paper. The test rig admits two different test bundles, namely, the inline-square and 45deg rotated-square tube arrays. Measurements were conducted to identify the flow-induced dynamic coefficients. The developed scheme was utilized in predicting the onset of flow-induced vibrations in two configurations of tube bundles, and results were examined in the light of Tubular Exchange Manufacturers Association (TEMA) predictions. The comparison demonstrated that TEMA guidelines are more conservative in the two configurations considered.

Author(s):  
Yehia A. Khulief ◽  
Salem A. Bashmal ◽  
Sayed A. Said ◽  
Dhawi A. Al-Otaibi ◽  
Khalid M. Mansour

The prediction of flow rates at which the vibration-induced instability takes place in tubular heat exchangers due to cross-flow is of major importance to the performance and service life of such equipment. In this paper, the semi-analytical model developed in [1] for square tube arrays was extended and utilized to study the triangular tube patterns. A laboratory test rig with instrumented test section is used to measure the fluidelastic coefficients to be used for tuning the mathematical model. The test section can be made of any bundle pattern. In this study, two test sections were constructed for both the normal triangular and the rotated triangular tube arrays. The developed scheme is utilized in predicting the onset of flow-induced instability in the two triangular tube arrays. The results are compared to those obtained for two other bundle configurations; namely the square and rotated square arrays reported in [1]. The results of the four different tube patterns are viewed in the light of TEMA predictions. The comparison demonstrated that TEMA guidelines are more conservative in all configurations considered.


Author(s):  
Y. A. Khulief ◽  
S. A. Said

It has been recognized that modeling of the complex dynamics of fluidelastic forces, that give rise to vibrations of tube bundles, requires a comprehensive dynamic model of high fidelity based on experimental insight. Accordingly, the prediction of the flow-induced vibration due to unsteady cross-flow can be greatly aided by semi-analytical models, in which some coefficients are determined experimentally. In this paper, the elastodynamic model of the tube array is formulated using the finite element approach, wherein each tube is modeled by a set of finite tube-elements. The interaction between tubes in the bundle is represented by fluidelastic coupling forces, which are defined in terms of the multi-degree-of-freedom elastodynamic behavior of each tube in the bundle. A laboratory test rig with an instrumented square bundle is constructed to measure the fluidelastic coefficients used to tune the developed dynamic model. The test rig admits two different test bundles; namely the inline-square and 45° rotated-square tube arrays. Measurements were conducted to identify the flow-induced dynamic coefficients. The developed scheme was utilized in predicting the onset of flow-induced vibrations, and results were examined in the light of TEMA predictions. The comparison demonstrated that TEMA guidelines are more conservative in the two configurations considered.


2009 ◽  
Vol 131 (3) ◽  
Author(s):  
Paul Feenstra ◽  
David S. Weaver ◽  
Tomomichi Nakamura

Laboratory experiments were conducted to determine the flow-induced vibration response and fluidelastic instability threshold of model heat exchanger tube bundles subjected to a cross-flow of refrigerant 11. Tube bundles were specially built with tubes cantilever-mounted on rectangular brass support bars so that the stiffness in the streamwise direction was about double that in the transverse direction. This was designed to simulate the tube dynamics in the U-bend region of a recirculating-type nuclear steam generator. Three model tube bundles were studied, one with a pitch ratio of 1.49 and two with a smaller pitch ratio of 1.33. The primary intent of the research was to improve our understanding of the flow-induced vibrations of heat exchanger tube arrays subjected to two-phase cross-flow. Of particular concern was to compare the effect of the asymmetric stiffness on the fluidelastic stability threshold with that of axisymmetric stiffness arrays tested most prominently in literature. The experimental results are analyzed and compared with existing data from literature using various definitions of two-phase fluid parameters. The fluidelastic stability thresholds of the present study agree well with results from previous studies for single-phase flow. In two-phase flow, the comparison of the stability data depends on the definition of two-phase flow velocity.


Author(s):  
Paul Feenstra ◽  
David S. Weaver ◽  
Tomomichi Nakamura

Laboratory experiments were conducted to determine the flow-induced vibration response and fluidelastic instability threshold of a model heat exchanger tube bundle subjected to a cross-flow of refrigerant 11. Tube bundles were specially built with cantilevered tubes mounted on asymmetric supports so that the stiffness in the streamwise direction was about double that of the transverse direction. This was designed to simulate the tube dynamics in the U-bend region of a recirculating-type nuclear steam generator. Three model tube bundles were tested, one with a pitch ratio of 1.49 and two with a smaller pitch ratio of 1.33. The primary intent of the research was to improve our understanding of the flow-induced vibrations of heat exchanger tube arrays subjected to two-phase cross-flow. Of particular concern was to compare the effect of the asymmetric support stiffness on the fluidelastic stability threshold with that of symmetric stiffness arrays tested most prominently in the literature. The experimental results are analysed and compared with existing data from the literature using various definitions of two-phase fluid parameters. The fluidelastic stability thresholds of the present study agree well with results from previous studies for single phase flow. In two-phase flow, the comparison of the stability data depends upon the definition of two-phase flow velocity.


Author(s):  
Amro Elhelaly ◽  
Marwan Hassan ◽  
Atef Mohany ◽  
Soha Moussa

The integrity of tube bundles is very important especially when dealing with high-risk applications such as nuclear steam generators. A major issue to system integrity is the flow-induced vibration (FIV). FIV is manifested through several mechanisms including the most severe mechanism; fluidelastic instability (FEI). Tube vibration can be constrained by using tube supports. However, clearances between the tube and their support are required to allow for thermal expansion and for other manufacturing considerations. The clearance between tubes may allow frequent impact and friction between tube and support. This in turn may cause fatigue and wear at support and potential for catastrophic tube failure. This study aims to investigate the dynamics of loosely supported tube array subjected to cross-flow. The work is performed experimentally in an open-loop wind tunnel to address this issue. A loosely-supported single flexible tube in both triangle and square arrays subjected to cross-flow with a pitch-to-diameter ratio of 1.5 and 1.733, respectively were considered. The effect of the flow approach angle, as well as the support clearance on the tube response, are investigated. In addition, the parameters that affect tube wear such as impact force level are presented.


2020 ◽  
Vol 143 (2) ◽  
Author(s):  
Omar Afifi ◽  
Atef Mohany

Abstract Flow-excited acoustic resonance is a design concern in many industrial applications. If not treated, it may lead to excessive vibrational loads, which could subsequently result in premature structural failure of critical equipment. For the case of tube bundles in heat exchangers, several acoustic damping criteria were proposed in the literature to predict the occurrence of resonance excitation. However, these criteria, in some cases, are not reliable in differentiating between the resonant and nonresonant cases. A primary reason for that is the geometrical differences between reduced scale models and full-scale tube bundles, and their effect on the flow-sound interaction mechanism. Therefore, the effect of two geometrical aspects, namely, the duct height and the cylinder diameter, on the self-excited acoustic resonance for single cylinders in cross-flow is experimentally investigated in this work. Changing the duct height changes the natural frequency of the excited acoustic modes and the duct's acoustic damping and radiation losses. Changing the cylinder diameter changes the flow velocity at frequency coincidence, the pressure drop, and Reynolds number. It is found that increasing the duct height decreases the acoustic impedance, which makes the system more susceptible to resonance excitation. This, in turn, changes the magnitude of the acoustic pressure at resonance, even for cases where the dynamic head of the flow is kept constant. The acoustic attenuation due to visco-thermal losses is quantified theoretically using Kirchhoff's acoustical damping model, which takes into account the geometrical aspects of the different ducts. Results from the experiments are compared with the acoustic damping criteria from the literature for similar cases. It is revealed that the height of the duct is an important parameter that should be included in damping criteria proposed for tube bundles of heat exchangers, as it controls the acoustic damping and radiation losses of the system, which have been over-looked in the past.


1984 ◽  
Vol 106 (1) ◽  
pp. 17-24 ◽  
Author(s):  
K. Ohta ◽  
K. Kagawa ◽  
H. Tanaka ◽  
S. Takahara

This paper presents a method to calculate the critical flow velocity of fluidelastic vibration of tube arrays in heat exchangers. The method is based upon the modal analysis technique, which combines the fluid dynamic force caused by cross flow and the vibration characteristics of the complicated tube array to obtain its response. The analytical method enables us not only to take into account the vibration mode of tube array and nonuniformity of velocity and density distribution of cross flow, but also to estimate the effect of antivibration devices, such as spacer, connecting band, and so on. Numerical examples of constrained single-tube array, multi-tube array in reversed flow, and group of panels with spacers are described.


Author(s):  
Shahab Khushnood ◽  
Zaffar M. Khan ◽  
M. Afzaal Malik ◽  
Zafarullah Koreshi ◽  
Mahmood Anwar Khan

Flow-induced vibration in steam generator and heat exchanger tube bundles has been a source of major concern in nuclear and process industry. Tubes in a bundle are the most flexible components of the assembly. Flow induced vibration mechanisms, like fluid-elastic instability, vortex shedding, turbulence induced excitation and acoustic resonance results in failure due to mechanical wear, fretting and fatigue cracking. The general trend in heat exchanger design is towards larger exchangers with increased shell side velocities. Costly plant shutdowns have been the motivation for research in the area of cross-flow induced vibration in steam generators and process exchangers. The current paper focuses on the development of a computer code (FIVPAK) for the design (natural frequencies, variable geometry, tube pitch & pattern, mass damping parameter, reduced velocity, strouhal and damage numbers, added mass, wear work rates, void fraction for two-phase, turbulence and acoustic considerations etc.) of tube bundles with respect to cross flow-induced vibration. The code has been validated against Tubular Exchanger Manufacturers (TEMA), Flow-Induced Vibration code (FIV), and results on an actual variable geometry exchanger, specially manufactured to simulate real systems. The proposed code is expected to prove a useful tool in designing a tube bundle and to evaluate the performance of an existing system.