Transient Temperature Distribution in a Spherical Region Subjected to a Variable Surface Heat Flux

1967 ◽  
Vol 89 (3) ◽  
pp. 278-279 ◽  
Author(s):  
Richard A. Matula
1989 ◽  
Vol 111 (4) ◽  
pp. 1108-1111 ◽  
Author(s):  
J. J. Heckel ◽  
T. S. Chen ◽  
B. F. Armaly

1995 ◽  
Vol 117 (3) ◽  
pp. 693-697 ◽  
Author(s):  
J. C. Chen ◽  
K. K. Hsu

Several boiling regimes are characterized by intermittent contacts of vapor and liquid at the superheated wall surface. A microthermocouple probe was developed capable of detecting transient surface temperatures with a response time better than 1 ms. The transient temperature data were utilized to determine the time-varying heat flux under liquid contacts. The instantaneous surface heat flux was found to vary by orders of magnitude during the milliseconds of liquid residence at the hot surface. The average heat flux during liquid contact was found to range from 105 to 107 W/m2 for water at atmospheric pressure, as wall superheat was varied from 50 to 450°C.


Author(s):  
Sanjeev Kumar Manjhi ◽  
Rakesh Kumar

Abstract In many engineering applications, the heating condition changes in a millisecond or less, thus to study such conditions, the coaxial thermocouples (CTs) are used because they have fast responding capability. The present study reveals the construction of K, E, and J-type of coaxial thermocouples and comparative investigation of performance parameters such as determination of thermal coefficient resistance, sensitivity, thermal product (TP), transient temperatures, surface heat flux, response time, and the comparative analysis are performed. These coaxial thermocouples are exposed to four different step heat loads (5 kW/m2, 25 kW/m2, 50 kW/m2, and 70 kW/m2) supplied by a continuous-wave type laser source. Subsequently, the transient temperature histories have been captured for 1.5 s, as well as the thermal product and the surface heat flux are assessed through one-dimensional heat conduction modeling for a semi-infinite body. For the known wattage input heat load, the finite element and analytical study have been done to compare the experimental outcomes. The experimental results have reasonable accuracy with the numerical and analytical results. The average error calculated for transient temperatures and evaluated heat flux are ±0.25% and ±2.5%, and the response times of these coaxial thermocouples are calculated as 40 µs, 36 µs, and 46 µs for K, E, and J-type, respectively, which shows the measuring capability of these CTs for short-duration measurements.


Sign in / Sign up

Export Citation Format

Share Document