Experimental Investigation of a Pulsating Heat Pipe Using Ferrofluid (Magnetic Nanofluid)

2011 ◽  
Vol 134 (1) ◽  
Author(s):  
Maziar Mohammadi ◽  
Mohammad Mohammadi ◽  
M. B. Shafii

In this work, a four-turn pulsating heat pipe (PHP) is fabricated and tested experimentally. The novelty of the present PHP is the capability to obtain various thermal performances at a specific heat input by changing the magnetic field. The effects of working fluid (water and ferrofluid), charging ratio (40% and 70%), heat input (35, 45, 55, 65, 75, and 85 W), orientation (horizontal and vertical heat mode), ferrofluid volumetric concentration (2.5% and 7%), and magnetic field on the thermal performance of PHPs are investigated. The results showed that applying the magnetic field on the water-based ferrofluid reduced the thermal resistance of PHP in all orientations. In the presence of a magnetic field, the best thermal performance was achieved at the higher charging ratios (70%) in all orientations.

Author(s):  
Maziar Mohammadi ◽  
Mohammad Mohammadi ◽  
Amir R. Ghahremani ◽  
M. B. Shafii

In this work, a four-turn Pulsating Heat Pipe (PHP) is fabricated and tested experimentally. The novelty of the present PHP is the capability of obtaining various thermal performances at a specific heat input by changing the magnetic field. The effects of working fluid (water and ferrofluid), charging ratio (25%, 40%, and 55%), heat input (25, 35, 45, 55, 65, 75, and 85 W), orientation (vertical and horizontal heat mode), and magnetic field on the thermal performance of PHPs are investigated. The results showed that applying the magnetic field on the water based ferrofluid reduced the thermal resistance of PHP by a factor of 40.5% and 38.3% in comparison with the pure water case for the vertical and horizontal mode, respectively. According to the experimental results, an optimum thermal resistance of 0.38 °C/W was achieved at the following conditions: water-based ferrofluid as the working fluid in the presence of magnetic field, vertical mode, charging ratio of 55%, 7% volumetric concentration, and 85 W heat input. This thermal resistance is 11.5 times better than that of the empty PHP.


Author(s):  
Mehdi Taslimifar ◽  
Maziar Mohammadi ◽  
Ali Adibnia ◽  
Hossein Afshin ◽  
Mohammad Hassan Saidi ◽  
...  

Homogenous dispersing of nanoparticles in a base fluid is an excellent way to increase the thermal performance of heat transfer devices especially Heat Pipes (HPs). As a wickless, cheap and efficient heat pipe, Pulsating Heat Pipes (PHPs) are important candidates for thermal application considerations. In the present research an Open Loop Pulsating Heat Pipe (OLPHP) is fabricated and tested experimentally. The effects of working fluid namely, water, Silica Coated ferrofluid (SC ferrofluid), and ferrofluid without surface coating of nanoparticles (ferrofluid), charging ratio, heat input, and application of magnetic field on the overall thermal performance of the OLPHPs are investigated. Experimental results show that ferrofluid has better heat transport capability relative to SC ferrofluid. Furthermore, application of magnetic field improves the heat transfer performance of OLPHPs charged with both ferrofluids.


Author(s):  
Maziar Mohammadi ◽  
Mehdi Taslimifar ◽  
Mohammad Hassan Saidi ◽  
Mohammad Behshad Shafii ◽  
Hossein Afshin ◽  
...  

The present work investigates the thermal performance of a five turn Open Loop Pulsating Heat Pipe (OLPHP). The effects of working fluid namely water and ferrofluid, heat input, ferrofluid concentration, charging ratio, and orientation will be considered. Experimental results show that using ferrofluids can enhance the thermal performance in comparison with the case of distilled water. In addition, applying a magnetic field on the OLPHP charged with ferrofluid reduces its thermal resistance. Variation of the ferrofluid concentration results in different thermal performance of the OLPHP. Best charging ratio for the distilled water and ferrofluid without magnetic field is 60% in most of the cases, while in the case of ferrofluid in the presence of magnetic field at low heat inputs, 20% and at high heat inputs 60% of charging ratios have lowest thermal resistance.


2012 ◽  
Vol 433-440 ◽  
pp. 5854-5860 ◽  
Author(s):  
Yu Wang ◽  
Wei Yi Li

Closed loop pulsating heat pipe (CLPHP) is a relatively new two-phase passive heat transfer device to suit present requirement of high heat flux dissipation in modern electronic components. The operating mechanism of CLPHP is not well understood and the present state of the technology cannot predict required design parameters for a given task. The aim of research work presented in this paper is to better understand thermal performance of CLPHP. A series of experimental investigation were conducted on a multi-turn CLPHP made of copper capillary tube of 2-mm inner diameter. Two kinds of working fluids viz. ethanol and acetone were employed. The influence characterization has been studied for the variation of heat input and filling ratio (FR) of the tested CLPHP. Thermal performance of the CLPHP is evaluated by heat transfer and thermal resistance. The results strongly demonstrate the effect of heat input and FR of the working fluid on thermal performance of the device.


2016 ◽  
Vol 369 ◽  
pp. 42-47 ◽  
Author(s):  
Patrik Nemec ◽  
Zuzana Kolková ◽  
Milan Malcho

Heat pipe is well known device which is used to heat transfer phase-change of working fluid. Pulsating heat pipe (PHP) is special type of heat pipe which heat transfer by pulsating movement of working fluid. Article deals about operating activity and thermal performance measurement of this special heat pipe. Operating activity visualization of PHP was performed with PHP made from glass. The two types of PHPs were made. The first PHP has internal diameter of tube 1 mm, second PHP has internal diameter of tube 1.5 mm and both PHPs have eleven meanders. The working fluids used in PHP were water and Fluorinert FC-72. These fluids were chose for their different thermo-physical properties and the visualization observe formation of liquid and vapour phase working fluid during filling process and working operation.Next, the article describes thermal performance measurement of PHP depending on working fluid amount and heat source temperature. Measurement was performed with PHP made from copper tube with inner diameter 1.5 mm curved to the twenty one meanders and filled with water. The results give us image about formation and distribution of working fluid in pulsating heat pipe and about influence of working fluid amount on the heat transfer ability of pulsating heat pipe.


Author(s):  
Pramod R. Pachghare ◽  
Ashish M. Mahalle

The closed loop pulsating heat pipe (CLPHP) is a passive two-phase heat transfer device, patented by Akachi (1990). Due to its excellent features, PHP has been considered as one of the promising technologies for electronic cooling, heat exchanger, etc. This paper presents an experimental study shows the effect of inclination angle on the thermal performance of CLPHP, which consist of 10 turns of copper tubes having inner and outer diameter 2 mm and 3.6 mm respectively. The equal lengths of evaporator, condenser and adiabatic sections are 50 mm each. Different working fluids are used as R-134a, Methanol and Water. For all experimentations, an optimum filling ratio was maintained 50% by volume. The thermal performance have been investigated with different inclination angles (viz. 0°, 20°, 40°, 60° and 90°) at various heat input from 5 to 50W in the steps of 5W. The thermal resistance (which is inversely proportional to thermal performance) of CLPHP at various heat input are plotted for different working fluids. The result shows that, the thermal resistance decreases as heat input increases. But at low heat input i.e. upto 25W, the thermal resistance decreases rapidly and the PHP performance is more sensitive to the inclination angle whereas high heat input i.e. above 25W, the thermal resistance decreases smoothly and less independent to the inclination angle. In all inclination angles, vertical bottom heat position (at 90°) of CLPHP gives best thermal performance due to presence of gravity force. At all inclination angles, the working fluid R-134a show best thermal performance followed by methanol and water.


Author(s):  
Mehdi Taslimifar ◽  
Maziar Mohammadi ◽  
Mohammad Hassan Saidi ◽  
Hossein Afshin ◽  
Mohammad Behshad Shafii ◽  
...  

In the present research an experimental investigation is performed to explore the effects of working fluid, heat input, ferrofluid concentration, magnets location, and inclination angle on the thermal performance of an Open Loop Pulsating Heat Pipe (OLPHP). Obtained results show that using ferrofluid can improve the thermal performance and applying a magnetic field on the water based ferrofluid decreases the thermal resistance. It shows that at an inclination angle of the OLPHP to be zero, the thermal performance of the present OLPHP reduces. Best heat transfer capability was achieved at 67.5 degree relative to horizontal axis for all of working fluids. Variation of the magnets location leads to a different thermal resistance in the OLPHP charged with ferrofluid.


2017 ◽  
Vol 865 ◽  
pp. 137-142
Author(s):  
Somchai Maneewan ◽  
Chantana Punlek ◽  
Hoy Yen Chan ◽  
Atthakorn Thongtha

Heat transfer performances of a pulsating heat pipe (PHP) having internal and external diameter with 4.5 mm and 6 mm with various contents of refrigerant are experimentally investigated. The working fluid as R404A refrigerant was filled in the volume ratios from 0% to 80% and the heat input was controlled in the range from 10 W to 80 W. Obtained results exhibited the ability of R404A refrigerant can enhance the thermal performance in steady state condition. The average temperature difference of the evaporating section and condensing section in the 80% filling volume ratio decreased from 9.5 °C to 2.5 °C when the heating power increase from 10 W to 80 W. The thermal resistance of evaporator and condenser decreased with an increase of the heat input as well. For other filling volume ratios, the trend of temperature difference and thermal resistance was similar to that of the 80% volume filling ratio. Considering the same heat input, the highest heat transfer performance was found at the 80% volume filling ratio. Refrigerant with a relatively low dynamic consistency can lead to relatively high velocity in the PHP that can reduce the temperature difference between the evaporating section and condensing section.


10.14311/1119 ◽  
2009 ◽  
Vol 49 (2) ◽  
Author(s):  
F. Cingroš ◽  
T. Hron

This paper deals with heat pipes controlled by a static magnetic field and with an important side effect – the quantity of working fluid. Heat pipes are able to provide very effective heat transport. Several standard regulation methods are commonly used for this purpose. In previous experiments implemented in our laboratory, we have observed the significant influence of a magnetic field on the heat conductance of the selected heat pipe. A special heat pipe was manufactured for this purpose and pure oxygen was chosen as a working fluid, due to its suitable magnetic properties. The heat pipe operation and the magnetic field control depend on various parameters. This paper is focused on the influence of the quantity of working fluid. Some important results of our experiments are presented and discussed. 