Investigation of Flow Field at the Inlet of a Turbocharger Compressor Using Digital Particle Image Velocimetry

2019 ◽  
Vol 141 (12) ◽  
Author(s):  
Deb Banerjee ◽  
Rick Dehner ◽  
Ahmet Selamet ◽  
Kevin Tallio ◽  
Keith Miazgowicz ◽  
...  

Abstract The flow field at the inlet of a turbocharger compressor has been studied through stereoscopic particle image velocimetry (SPIV) experiments under different operating conditions. It is found that the flow field is quite uniform at high mass flow rates; but as the mass flow rate is reduced, flow reversal from the impeller is observed as an annular ring at the periphery of the inlet duct. The inception of flow reversal is observed to occur in the mid-flow operating region, near peak efficiency, and corresponds to an incidence angle of about 15.5 deg at the inducer blade tips at all tested speeds. This reversed flow region is marked with high tangential velocity and rapid fluctuations. It grows in strength with reducing mass flow rate and imparts some of its angular momentum to the forward flow due to mixing. The penetration depth of the reversed flow upstream from the inducer plane is found to increase quadratically with decreasing flow rate.

Author(s):  
Deb Banerjee ◽  
Rick Dehner ◽  
Ahmet Selamet ◽  
Keith Miazgowicz

Abstract Turbocharger surge remains an area of concern for the automotive industry as it limits the permissible operating range on the compressor map, while also adversely impacting the compressor’s pressure rise, efficiency, and acoustics. The present study uses Stereoscopic Particle Image Velocimetry (SPIV) to investigate the flow field at the inlet of an automotive turbocharger compressor without a recirculating channel. Experiments were carried out at four different speeds, including 80, 100, 120, and 140 krpm, which represent a substantial portion of the compressor map. The mass flow rates investigated ranged from choke to deep surge, thus spanning the entire mass flow regime at each rotational speed. The current work aims to characterize how the compressor inlet velocity field varies with rotational speed, with a specific emphasis on surge. The qualitative nature of the flow field (radial dependence of axial and tangential velocity profiles), over the choke to mild surge range, was observed to be nearly independent of rotational speed for comparable operating conditions (for example, comparison of mild surge at different rotational speeds). A quantitative comparison of the velocity profiles at the choke or mild surge operating points showed an increase in the velocity magnitudes with increasing rotational speed. The flow field at deep surge, however, was observed to change substantially from 80 krpm to 140 krpm. At 80 krpm, the character of the flow field at different times (at different points on the surge cycle) was observed to be similar: the core flow near the center of the duct was always directed into the impeller, whereas the reversed flow occupied an annular region near the periphery in nearly all time instances. However, as the rotational speed was increased to 140 krpm, the variation in the flow field at different instances within a deep surge cycle increased. At 140 krpm, the negative flow rate (where the cross-sectional average flow is directed out of the inducer back into the inlet duct) portion of the surge cycle was still similar to the overall surge flow field at 80 krpm, but over a substantial part of the positive flow rate (cross-sectional average flow is directed into the impeller) portion of the surge cycle, there was no sign of reversed flow within the visualization domain. As the rotational speed was increased, the surge loop (obtained by combining the PIV and pressure transducer data) extended over a wider portion of the compressor map with higher maximum (positive) and minimum (negative) flow rates, along with higher amplitude pressure fluctuations. The mean amplitude of mass flow rate and pressure ratio fluctuations at deep surge increased in nearly a quadratic fashion with rotational speed. The deep surge frequency did not change substantially over the range of rotational speeds examined in this study.


2021 ◽  
Vol 143 (6) ◽  
Author(s):  
Deb Banerjee ◽  
Rick Dehner ◽  
Ahmet Selamet ◽  
Keith Miazgowicz

Abstract Stereoscopic particle image velocimetry is used to characterize the variation of the turbocharger compressor inlet velocity field as a function of rotational speed, with an emphasis on surge. While the velocity magnitudes at choke or mild surge increased with rotational speed, the velocity profiles remained qualitatively similar. The variation in deep surge flow field with shaft speed, however, was more substantial. At 80 krpm, the overall flow field was comparable at different time instances (at different points on the surge cycle): the core flow near the duct center was always directed into the impeller, whereas reversed flow occupied an annular region near the periphery in nearly all time instances. However, at 140 krpm, while the negative flow rate (cross-sectional average flow is directed out of the inducer back into the inlet duct) portion of the surge cycle was still similar to the overall surge flow field at 80 krpm, over a substantial part of the positive flow rate (cross-sectional average flow is directed into the impeller) portion of the surge cycle, there was no sign of reversed flow within the visualization domain. As the rotational speed was increased, the surge loop (obtained by combining the particle image velocimetry (PIV) and pressure transducer data) extended over a wider portion of the compressor map with higher maximum (positive) and minimum (negative) flow rates, along with higher amplitude pressure fluctuations. The mean amplitude of mass flow rate and pressure ratio fluctuations at deep surge increased in nearly a quadratic fashion with rotational speed.


Author(s):  
Deb Banerjee ◽  
Rick Dehner ◽  
Ahmet Selamet ◽  
Keith Miazgowicz ◽  
Todd Brewer ◽  
...  

Abstract Understanding the velocity field at the inlet of an automotive turbocharger is critical in order to suppress the instabilities encountered by the compressor, extend its map and improve the impeller design. In the present study, two-dimensional particle image velocimetry experiments are carried out on a turbocharger compressor without any recirculating channel to investigate the planar flow structures on a cross-sectional plane right in front of the inducer at a rotational speed of 80 krpm. The objective of the study is to investigate the flow field in front of a compressor blade passage and quantify the velocity distributions along the blade span for different mass flow rates ranging from choke (77 g/s) to deep surge (13.6 g/s). It is observed that the flow field does not change substantially from choke to about 55 g/s, where flow reversal is known to start at this speed from earlier measurements. While the tangential velocity is less than 8 m/s, the radial velocity increases along the span to 17–20 m/s near the tip at high flow rates (55–77 g/s). As the mass flow rate is reduced below 55 g/s, the radial component starts decreasing and the tangential velocity increases rapidly. From about 5 m/s at 55 g/s, the tangential velocity at the blade tip exceeds 50 m/s at 50 g/s and reaches a maximum of about 135 m/s near surge. These time-averaged distributions are similar for different angular locations in front of the blade passage and do not exhibit any substantial azimuthal variation.


2012 ◽  
Vol 16 (5) ◽  
pp. 1414-1418 ◽  
Author(s):  
Xiao-Yu Liang ◽  
Huan-Huan Wu ◽  
Cheng-Xu Tu ◽  
Kai Zhang

The visualization measurement of internal flow field in a curved expansion duct is experimentally studied using particle image velocimetry technology and the influence of flow rate on flow field is analyzed. The streamline distribution and related performance curve in the internal flow field can be figured out through further analysis of experiment data. The results show that fiber orientation is mainly affected by velocity gradient, the fibers near the wall are aligned with the flow direction more quickly than the fibers in intermediate region, and the fibers near the concave wall are more quickly aligned with the flow direction than the convex wall. The larger inlet flow rate which will accordingly lead to increase inlet velocity enables the more quick adaptation and steady of fibers in flow direction.


2002 ◽  
Vol 33 (6) ◽  
pp. 794-800 ◽  
Author(s):  
U. Dierksheide ◽  
P. Meyer ◽  
T. Hovestadt ◽  
W. Hentschel

2010 ◽  
Vol 43 (6) ◽  
pp. 1039-1047 ◽  
Author(s):  
Emily J. Berg ◽  
Jessica L. Weisman ◽  
Michael J. Oldham ◽  
Risa J. Robinson

2018 ◽  
Vol 20 (6) ◽  
pp. 624-639 ◽  
Author(s):  
Kang Song ◽  
Ben Zhao ◽  
Harold Sun ◽  
Weilin Yi

Turbocharger compressor, when fitted to a vehicle, usually operates with a curved inlet pipe which leads to distorted inlet flow field, hence deteriorating compressor flow capability. During the measurement of compressor performance, turbocharger-engine matching and controller design, the inlet flow field is, however, assumed to be uniform, which deviates from the real-world conditions. Consequently, the overall system performance could be compromised if the inlet distortion effect is ignored. To address this issue, in this article, a turbomachinery physics-based zero-dimensional model was proposed for the mass flow rate of a compressor with distorted inlet flow field due to 90° and 180° bent inlet pipe. The non-uniform flow is approximated as two-zone flow field, similar to parallel compressors, with the total pressure deviation between two zones modeled as a function of the flow velocity and pipe geometry. For each flow zone, the corresponding mass flow rate is estimated by approximating each sub-compressor as an adiabatic nozzle, where the fluid is driven by external work delivered by a compressor wheel governed by Euler’s turbomachinery equation. By including turbomachinery physics and compressor geometry information into the modeling, the model achieves high fidelity in compressor map interpretation and extrapolation, which is validated in experiments and the three-dimensional computational fluid dynamic simulation.


2021 ◽  
Author(s):  
Raghuvaran D. ◽  
Satvik Shenoy ◽  
Srinivas G

Abstract Axial flow fans (AFF) are extensively used in various industrial sectors, usually with flows of low resistance and high mass flow rates. The blades, the hub and the shroud are the three major parts of an AFF. Various kinds of optimisation can be implemented to improve the performance of an AFF. The most common type is found to be geometric optimisation including variation in number of blades, modification in hub and shroud radius, change in angle of attack and blade twist, etc. After validation of simulation model and carrying out a grid independence test, parametric analysis was done on an 11-bladed AFF with a shroud of uniform radius using ANSYS Fluent. The rotational speed of the fan and the velocity at fan inlet were the primary variables of the study. The variation in outlet mass flow rate and total pressure was studied for both compressible and incompressible ambient flows. Relation of mass flow rate and total pressure with inlet velocity is observed to be linear and exponential respectively. On the other hand, mass flow rate and total pressure have nearly linear relationship with rotational speed. A comparison of several different axial flow tracks with the baseline case fills one of the research gaps.


Sign in / Sign up

Export Citation Format

Share Document