Effects of Orientation Angles on Film Cooling Over a Flat Plate: Boundary Layer Temperature Distributions and Adiabatic Film Cooling Effectiveness

1999 ◽  
Vol 122 (1) ◽  
pp. 153-160 ◽  
Author(s):  
In Sung Jung ◽  
Joon Sik Lee

Presented are experimental results describing the effects of orientation angle of film cooling holes on boundary layer temperature distributions and film cooling effectiveness. Film flow data were obtained from a row of five film cooling holes on a flat test plate. The inclination angle of the hole was fixed at 35 deg and four orientation angles of 0, 30, 60, and 90 deg were investigated. The velocity ratios surveyed were 0.5, 1.0, and 2.0. The boundary layer temperature distributions were measured at three downstream locations using 1μm platinum wire. Detailed adiabatic film cooling effectiveness distributions were measured using thermochromic liquid crystal. Results show that the increased lateral momentum in the case of large orientation angle injection strongly affects boundary layer temperature distributions. Temperature distribution characteristics are, in general, explained in the context of the interactions between injectant and free-stream fluid and between injectants issuing from adjacent holes. The adiabatic film cooling effectiveness distributions are discussed in connection with the boundary layer temperature distributions. Spanwise-averaged effectiveness distributions and space-averaged effectiveness distributions are also presented with respect to the velocity ratios and the orientation angles. [S0889-504X(00)01701-3]

Author(s):  
In Sung Jung ◽  
Joon Sik Lee

Presented are experimental results describing the effects of orientation angle of film cooling holes on boundary layer temperature distributions and film cooling effectiveness. Film flow data were obtained from a row of five film cooling holes on a flat test plate. The inclination angle of the hole was fixed at 35° and four orientation angles of 0°, 30°, 60°, and 90° were investigated. The surveyed velocity ratios were 0.5, 1.0, and 2.0. The boundary layer temperature distributions were measured at three downstream locations using turn platinum wire. Detailed adiabatic film cooling effectiveness distributions were measured using thermochromic liquid crystal. Results show that the increased lateral momentum in the case of large orientation angle injection strongly affects boundary layer temperature distributions. Temperature distribution characteristics are, in general, explained in the context of the interactions between injectant and free-stream fluid and between injectants issued from adjacent holes. The adiabatic film cooling effectiveness distributions are discussed in connection with the boundary layer temperature distributions. Spanwise-averaged effectiveness distributions and space-averaged effectiveness distributions are also presented with respect to the velocity ratios and the orientation angles.


Author(s):  
Dong Kee Sohn ◽  
Joon Sik Lee

Effect of bulk flow pulsations on film cooling from two rows of holes with inline and staggered arrangements is experimentally investigated. As a baseline study, a single row injection is also tested. Two-row injection is important because the phase lag between the two rows may cause changes in the film coolant coverage. Potential flow pulsations are generated by the rotating shutter mechanism attached downstream of the test section. Free-stream Strouhal number based on the boundary layer thickness is in the range of 0.033–0.33, and the amplitude of the phase-averaged freestream velocity due to static pressure variation about 10–20% Both the time-averaged and phase-averaged temperature distributions in the cross-sectional plane of the boundary layer are presented for four different pulsation frequencies of 0, 4, 20 and 40 Hz. Film cooling effectiveness is evaluated from the adiabatic wall temperature distributions, with time-averaged temperature measurements showing rapid diffusion of the injectant due to the free-stream pulsations. Effect of the phase lag between two rows is evidenced from the phase-averaged measurements, particularly in the case of staggered hole arrangement. All film cooling effectiveness distributions are reduced compared to no-pulsation case. Effect of pulsations appears dominantly in the case of the two-row staggered arrangement which shows more than 35% reduction in the film cooling effectiveness.


Author(s):  
Dennis Brauckmann ◽  
Jens von Wolfersdorf

The measurement of adiabatic film cooling effectiveness data and heat transfer coefficient data for a row of fanshaped film cooling holes at different compound angles is presented in this paper. The measurements are performed at engine-like temperature ratios in a hot gas test facility on a flat test plate. For the film cooling geometry, a row of five laidback-fanshaped holes was used. The temperature distribution on the flat plate is measured using infrared-thermography (IR). Steady state measurements are used to obtain the film cooling effectiveness. For the determination of the heat transfer coefficient ratio with and without film cooling on the test plate, a transient measurement technique is applied. Results for both the adiabatic film cooling effectiveness and the heat transfer coefficient ratio are given. The influence of different blowing ratios on the injection with compound angles of 0°, 30° and 45° will be discussed. From this study, the increasing compound angle showed only small effects on the pitch-wise lateral averaged adiabatic film cooling effectiveness but increased the heat transfer on the film cooled flat plate with coolant injection.


Author(s):  
C. A. Hale ◽  
S. Ramadhyani ◽  
M. W. Plesniak

This study evaluates the ability of available turbulence models in the commercial software FLUENT to predict film cooling effectiveness for a single row of short (L / D = 2.91). film cooling holes fed by a narrow plenum (H / D = 1). The results are compared to experimental data obtained by the present investigators. The study concentrates on the near-hole region for the geometry being studied experimentally by the present investigators. The results of the study indicate that the use of wall functions to predict film cooling effectiveness in the near-hole region is inappropriate due to the boundary layer separation in that region. Also, the ability of the Reynolds Stress turbulence model to better predict spanwise spreading of the jet indicates the need for anisotropic turbulnce model capabilities to better predict film cooling effectiveness.


Author(s):  
Lin Ye ◽  
Cun-liang Liu ◽  
Hai-yong Liu ◽  
Hui-ren Zhu ◽  
Jian-xia Luo

To investigate the effects of the inclined ribs on internal flow structure in film hole and the film cooling performance on outer surface, experimental and numerical studies are conducted on the effects of rib orientation angle on film cooling of compound cylindrical holes. Three coolant channel cases, including two ribbed cross-flow channels (135° and 45° angled ribs) and the plenum case, are studied under three blowing ratios (0.5, 1.0 and 2.0). 2D contours of film cooling effectiveness as well as heat transfer coefficient were measured by transient liquid crystal measurement technique (TLC). The steady RANS simulations with realizable k-ε turbulence model and enhanced wall treatment were performed. The results show that the spanwise width of film coverage is greatly influenced by the rib orientation angle. The spanwise width of the 45° rib case is obviously larger than that of the 135° rib case under lower blowing ratios. When the blowing ratio is 1.0, the area-averaged cooling effectiveness of the 135° rib case and the 45° rib case are higher than that of the plenum case by 38% and 107%, respectively. With the increase of blowing ratio, the film coverage difference between different rib orientation cases becomes smaller. The 45° rib case also produces higher heat transfer coefficient, which is higher than the 135° rib case by 3.4–8.7% within the studied blowing ratio range. Furthermore, the discharge coefficient of the 45° rib case is the lowest among the three cases. The helical motion of coolant flow is observed in the hole of 45° rib case. The jet divides into two parts after being blown out of the hole due to this motion, which induces strong velocity separation and loss. For the 135° rib case, the vortex in the upper half region of the secondary-flow channel rotates in the same direction with the hole inclination direction, which leads to the straight streamlines and thus results in lower loss and higher discharge coefficient.


2019 ◽  
Vol 141 (3) ◽  
Author(s):  
Dale W. Fox ◽  
Fraser B. Jones ◽  
John W. McClintic ◽  
David G. Bogard ◽  
Thomas E. Dyson ◽  
...  

Most studies of turbine airfoil film cooling in laboratory test facilities have used relatively large plenums to feed flow into the coolant holes. However, a more realistic inlet condition for the film cooling holes is a relatively small channel. Previous studies have shown that the film cooling performance is significantly degraded when fed by perpendicular internal crossflow in a smooth channel. In this study, angled rib turbulators were installed in two geometric configurations inside the internal crossflow channel, at 45 deg and 135 deg, to assess the impact on film cooling effectiveness. Film cooling hole inlets were positioned in both prerib and postrib locations to test the effect of hole inlet position on film cooling performance. A test was performed independently varying channel velocity ratio and jet to mainstream velocity ratio. These results were compared to the film cooling performance of previously measured shaped holes fed by a smooth internal channel. The film cooling hole discharge coefficients and channel friction factors were also measured for both rib configurations with varying channel and inlet velocity ratios. Spatially averaged film cooling effectiveness is largely similar to the holes fed by the smooth internal crossflow channel, but hole-to-hole variation due to inlet position was observed.


Author(s):  
John W. McClintic ◽  
Joshua B. Anderson ◽  
David G. Bogard ◽  
Thomas E. Dyson ◽  
Zachary D. Webster

In gas turbine engines, film cooling holes are commonly fed with an internal crossflow, the magnitude of which has been shown to have a notable effect on film cooling effectiveness. In Part I of this study, as well as in a few previous studies, the magnitude of internal crossflow velocity was shown to have a substantial effect on film cooling effectiveness of axial shaped holes. There is, however, almost no data available in the literature that shows how internal crossflow affects compound angle shaped film cooling holes. In Part II, film cooling effectiveness, heat transfer coefficient augmentation, and discharge coefficients were measured for a single row of compound angle shaped film cooling holes fed by internal crossflow flowing both in-line and counter to the span-wise direction of coolant injection. The crossflow-to-mainstream velocity ratio was varied from 0.2–0.6 and the injection velocity ratio was varied from 0.2–1.7. It was found that increasing the magnitude of the crossflow velocity generally caused degradation of the film cooling effectiveness, especially for in-line crossflow. An analysis of jet characteristic parameters demonstrated the importance of crossflow effects relative to the effect of varying the film cooling injection rate. Heat transfer coefficient augmentation was found to be primarily dependent on injection rate, although for in-line crossflow, increasing crossflow velocity significantly increased augmentation for certain conditions.


Author(s):  
Andrew F. Chen ◽  
Chao-Cheng Shiau ◽  
Je-Chin Han

The combined effects of inlet purge flow and the slashface leakage flow on the film cooling effectiveness of a turbine blade platform were studied using the pressure sensitive paint (PSP) technique. Detailed film cooling effectiveness distributions on the endwall were obtained and analyzed. The inlet purge flow was generated by a row of equally-spaced cylindrical injection holes inside a single-tooth generic stator-rotor seal. In addition to the traditional 90 degree (radial outward) injection for the inlet purge flow, injection at a 45 degree angle was adopted to create a circumferential/azimuthal velocity component toward the suction side of the blades, which created a swirl ratio (SR) of 0.6. Discrete cylindrical film cooling holes were arranged to achieve an improved coverage on the endwall. Backward injection was attempted by placing backward injection holes near the pressure side leading edge portion. Slashface leakage flow was simulated by equally-spaced cylindrical injection holes inside a slot. Experiments were done in a five-blade linear cascade with an average turbulence intensity of 10.5%. The inlet and exit Mach numbers were 0.26 and 0.43, respectively. The inlet and exit mainstream Reynolds numbers based on the axial chord length of the blade were 475,000 and 720,000, respectively. The coolant-to-mainstream mass flow ratios (MFR) were varied from 0.5%, 0.75%, to 1% for the inlet purge flow. For the endwall film cooling holes and slashface leakage flow, blowing ratios (M) of 0.5, 1.0, and 1.5 were examined. Coolant-to-mainstream density ratios (DR) that range from 1.0 (close to low temperature experiments) to 1.5 (intermediate DR) and 2.0 (close to engine conditions) were also examined. The results provide the gas turbine engine designers a better insight into improved film cooling hole configurations as well as various parametric effects on endwall film cooling when the inlet (swirl) purge flow and slashface leakage flow were incorporated.


Author(s):  
Christian Saumweber ◽  
Achmed Schulz

A comprehensive set of generic experiments is conducted to investigate the interaction of film cooling rows. Five different film cooling configurations are considered on a large scale basis each consisting of two rows of film cooling holes in staggered arrangement. The hole pitch to diameter ratio within each row is kept constant at P/D = 4. The spacing between the rows is either x/D = 10, 20, or 30. Fanshaped holes or simple cylindrical holes with an inclination angle of 30 deg. and a hole length of 6 hole diameters are used. With a hot gas Mach number of Mam = 0.3, an engine like density ratio of ρc/ρm = 1.75, and a freestream turbulence intensity of Tu = 5.1% are established. Operating conditions are varied in terms of blowing ratio for the upstream and, independently, the downstream row in the range 0.5<M<2.0. The results illustrate the importance of considering ejection into an already film cooled boundary layer. Adiabatic film cooling effectiveness and heat transfer coefficients are significantly increased. The decay of effectiveness with streamwise distance is much less pronounced downstream of the second row primarily due to pre-cooling of the boundary layer by the first row of holes. Additionally, a comparison of measured effectiveness data with predictions according to the widely used superposition model of Sellers [11] is given for two rows of fanshaped holes.


2021 ◽  
Author(s):  
Izhar Ullah ◽  
Sulaiman M. Alsaleem ◽  
Lesley M. Wright ◽  
Chao-Cheng Shiau ◽  
Je-Chin Han

Abstract This work is an experimental study of film cooling effectiveness on a blade tip in a stationary, linear cascade. The cascade is mounted in a blowdown facility with controlled inlet and exit Mach numbers of 0.29 and 0.75, respectively. The free stream turbulence intensity is measured to be 13.5 % upstream of the blade’s leading edge. A flat tip design is studied, having a tip gap of 1.6%. The blade tip is designed to have 15 shaped film cooling holes along the near-tip pressure side (PS) surface. Fifteen vertical film cooling holes are placed on the tip near the pressure side. The cooling holes are divided into a 2-zone plenum to locally maintain the desired blowing ratios based on the external pressure field. Two coolant injection scenarios are considered by injecting coolant through the tip holes only and both tip and PS surface holes together. The blowing ratio (M) and density ratio (DR) effects are studied by testing at blowing ratios of 0.5, 1.0, and 1.5 and three density ratios of 1.0, 1.5, and 2.0. Three different foreign gases are used to create density ratio effect. Over-tip flow leakage is also studied by measuring the static pressure distributions on the blade tip using the pressure sensitive paint (PSP) measurement technique. In addition, detailed film cooling effectiveness is acquired to quantify the parametric effect of blowing ratio and density ratio on a plane tip design. Increasing the blowing ratio and density ratio resulted in increased film cooling effectiveness at all injection scenarios. Injecting coolant on the PS and the tip surface also resulted in reduced leakage over the tip. The conclusions from this study will provide the gas turbine designer with additional insight on controlling different parameters and strategically placing the holes during the design process.