Experience With a Fast Track Power Generation Project

Author(s):  
Albrecht H. Mayer ◽  
Noel W. Lively

To meet peaking power demands the E.W. Brown Station, owned and operated by Kentucky Utilities Company, was extended by two GT24 gas turbines. The project had to meet a 9-month engineering, construction and commissioning schedule. The conceptual design is based on ABB ALSTOM POWER’S reference plant design for combined cycle application. It was adjusted to the requirements of a simple cycle operation. Special plant features such as evaporative cooling of the inlet air, system design of the evaporative cooling system, performance and experience will be discussed in detail. The plant has an aggressive running and starting reliability goal; the approach to meet the required plant reliability will be discussed below. The initial operational feedback will be addressed as well as an outlook on how to meet all project goals.

Author(s):  
A. Behdashti ◽  
M. Ebrahimpour ◽  
B. Vahidi ◽  
V. Omidipour ◽  
A. Alizadeh

This paper discusses an optimized media type evaporative cooling system called Outdoor Movable Media cooler which has been recently implemented on two 160 MW, V94.2 gas turbines of Kerman combined cycle power plant, Iran. The air cooling system can be applied to retrieve the lost power generation capability of gas turbine during hot months. System description is completely presented and optimizations such as making a movable media cooler are described. The moving ability of this system eliminates the power loss related to the conventional media coolers. Furthermore, experimental work including evaluation of humidity effect on the air filters operation is discussed and the results are presented. The cooling system performance curve shows the system capability of cooling the inlet air up to 19°C at the design condition. This cooling capacity leads to power augmentation up to 14% which is noteworthy in responding to the electricity demand in hot months, when air-conditioning loads are maximized. Considering several parameters, a cost analysis is done finally and payback period of the system is calculated.


Author(s):  
Amir Abbas Zadpoor ◽  
Ali Asadi Nikooyan

The evaporative inlet cooling systems used for inlet cooling of gas turbines during hot summers do not work well in humid areas. However, desiccant wheels can be used to dehumidify the air before passing it trough the evaporative cooler. Since the desiccant wheels work adiabatically, the resulting air is hotter than the air introduced to the wheel and an evaporative cooling system is used to cool down the dehumidified air. Combined direct and indirect evaporative coolers have been already used to investigate the effects of dehumidification on the effectiveness of the evaporation cooling systems. It is shown that a single desiccant wheel does not offer much higher effectiveness compared to the multiple-stage evaporative systems. In this paper, an improved version of the desiccant inlet cooling system is presented. Additional dehumidification and indirect evaporative cooling stages are added to increase the effectiveness of the inlet cooling. A typical gas turbine cycle along with an industrial gas turbine with actual performance curves are used to simulate the thermal cycle in presence of the different inlet cooling systems. The simulations are carried out for three different climatic conditions. The improved and original desiccant-based systems are compared and it is shown that the added stages substantially improve the effectiveness of the desiccant-based inlet cooling.


Author(s):  
Hemant Gajjar

Inlet Air Cooling of gas turbine engines for power augmentation has seen increasing application over the past decade. Evaporative inlet air cooling has been particularly preferred by the Gas Turbine operators due to its low cost and ease of installation. Two of the important considerations for a GT operator are the proper selection of the EIAC and, after installation, its proper testing to assure required performance. This paper is based on the experience, as a user, of selecting a inlet air cooling system and then implementing a Fogging type Evaporative Cooling system. It highlights the important parameters related to evaporative cooling system and in particular fogging, and how the site testing can be handled to ensure proper performance. Concepts of ‘Conversion Effectiveness’ and ‘Evaporation Effectiveness’ have also been introduced in this paper.


2017 ◽  
Vol 139 (11) ◽  
Author(s):  
Jose Carmona

Water is a scarce natural resource fundamental for human life. Power plant architects, engineers, and power utilities owners must do everything within their hands and technical capabilities to decrease the usage of water in power plants. This paper illustrates the research carried out by Pöyry Switzerland to reduce the water consumption on power and desalination combined cycle power plants, on which there are gas turbine evaporative cooling systems in operation. The present study analyzed the potential re-utilization and integration of the heat recovery steam generator (HRSG) blowdown into the evaporative cooling system. Relatively clean demineralized water, coming from the HRSG blowdown, is routed to a large water tank, where it is blended with distillate water to achieve the required water quality, before being used on the gas turbine evaporative cooling system. To prove the feasibility of the HRSG blowdown recycling concept, the Ras Al Khair Power and Desalination Plant owned and operated by the Saline Water Conversion Corporation (SWCC), located in the Eastern Province of the Kingdom of Saudi Arabia, was used as case study. Nevertheless, it is important to mention that the principles and methodology presented on this paper are applicable to every power and desalination combined cycle power plant making use of evaporative cooling. Sea water desalination is the primary source for potable water production on Saudi Arabia, with secondary sources being surface water and groundwater extracted from deep wells and aquifers. Saving water is of utmost importance for power plants located in locations where water is scarce, and as such, this paper aims to demonstrate that it is possible to decrease the water consumption of power and desalination combined cycle plants, on which evaporative cooling is used as gas turbine power booster, without having to curtail power production. The outcome of the study indicates that during the summer season, recycling the HRSG water blowdown into the gas turbine evaporative cooling systems would result on the internal water consumption for the gas turbine evaporative coolers decreasing by 545 ton/day, or 23.79%, compared with the original plant design which does not contemplate blowdown re-use. Using evaporative cooling results on an overall gain of 186 MW, or 10.27%, on gross power output, while CO2 emissions decrease by 46.8 ton CO2/h, which represents a 13.8% reduction compared with the case on which the evaporative cooling system is not in operation. A brief cost analysis demonstrated that implementation of the changes would result in a negligible increase of the operational expenses (OPEX) of the plant, i.e., implementation of the suggested modification has an unnoticeable impact on the cost of electricity (CoE). The payback of the project, due to limited operating hours on evaporative cooling every year, is of 12 years for a 30 year plant lifetime, while 2.22 M USD of extra-revenue on potable water sales are generated as a result of implementing the proposed solution. Although in principle this value is modest, the effect of government subsidies on water tariffs as well as political and strategic cost of water is not included on the calculations. In conclusion, the study results indicate that water recycling, and reduction of plant's water footprint for power and desalination combined cycle plants using evaporative cooling, is not only technically possible but commercially feasible.


Author(s):  
Amir Abbas Zadpoor ◽  
Ali Asadi Nikooyan

The evaporative inlet cooling systems do not work well in humid areas. However, desiccant wheels can be used to dehumidify the air before passing it through the evaporative cooler. A previous study of combined direct and indirect evaporative coolers showed that a single desiccant wheel does not offer much higher effectiveness compared with the multistage evaporative systems. In this paper, additional dehumidification and indirect evaporative cooling stages are added to increase the effectiveness of the desiccant-based inlet cooling. A typical gas turbine cycle along with an industrial gas turbine with actual performance curves are used to study the performance of the proposed system in three different climatic conditions. It is shown that the added stages substantially improve the effectiveness of the desiccant-based inlet cooling.